PNOZ X3P
太原韩语培训产品描述
安全继电器PNOZ X3P被封装在一个45mm p-99的塑壳里面。该装置可以接24 ... 240 VAC/DC.的电源使用。
Description
The Safety Relay PNOZ X3P is enclod in a
45 mm P-99 housing. The unit can be
operated with 24 ... 240 VAC/DC.
特点
•继电器输出:3对常开触点和一对辅助触点。Positiveguided型触点。(指采用机械方式联接使常开和常闭触点永远不能同时闭合的触点)
gid•接线连接包括急停按钮、安全门限位开关、复位按钮。
•状态指示灯。
•扩展接触器/继电器的状态监视
•晶体管有输出表明装置已备妥。
继电器兼容以下安全标准要求:
•电路是含有内置自检功能的冗余设计--符合EN 954-1
•在自身组件失效的情况下安全功能仍然起作用
•安全功能继电器的正确开闭在每个on-off过程中被自动测试
•继电器装有一只电子式保险
Features:
• Relay outputs: 3 safety contacts (N/O)
and one auxiliary contact (N/C), positiveguided
• Connections for Emergency Stop Button,
Safety Gate Limit Switch and Ret
button
• Status Indicators
• Monitoring of external contactors/relays
possible
• Semi-conductor outputs show ready for
operation
The relay complies with the following safety
requirements:
• The circuit is redundant with built-in lfmonitoring
(EN 954-1 Category 4).
• The safety function remains effective in the
ca of a component failure.
• The correct opening and closing of the
safety function relays is tested
automatically in each on-off cycle.
• The relays has an electronic fu.
功能描述
Function Description
PNOZX3P为您提供一个安全趋向型的电路切断。A1、A2接通电源后,power灯点亮; 当 s13-s14闭合(自动复位用法)或者s33-s34端子接线的复位触点被打开并再次闭合后(手动复位用法),PNOZ X3P就处于备妥状态。
tothebeginningThe relay PNOZ X3P provides a safetyoriented
interruption of a safety circuit. When
the operating voltage is supplied the LED
"Power" is illuminated. The unit is ready for
operation, when the ret circuit S13-S14 is
clod or a ret contact at S33-S34 was
opened and clod again.
输入电路闭合(例如:急停按钮没有被按下时):k1、k2继电器得电吸合并自保----CH1,CH2状态指示灯点亮-----安全触点(13-14/23-24/33-34)闭合---辅助触点(41-42)打开。
• Input Circuit clod (e.g. the Emergency
Stop button is not presd):
Relays K1and K2 energi and retain
themlves. The status indicators for
"CH. 1" and "CH. 2" illuminate. The safety
contacts (13-14/23-24/33-34) are clod,
the auxiliary contact (41-42) is open.
输入电路断开后(例如:急停按钮按下时):k1、k2继电器释放知足者常乐英文----CH1,CH2状态指示灯熄灭-----安全触点(13-14/23-24/33-34)打开---辅助触点(41-42)闭合。
• Input Circuit is opened (e.g. Emergency
Stop is presd)
Relays K1 and K2 de-energi. The status
indicators for "CH.1" and "CH.2" go out.
The safety contacts (13-14/23-24/33-34) will
be opened (redundant), the auxiliary contact
(41-42) clos.
晶体管输出
如果K1、K2吸合,晶体管Y32将导通输出。当K1、K2失电释放,Y32将关断—状态复位。
Semi-conductor output
The mi-conductor Y32 conducts if the relays
K1 and K2 are energid. Y32 switches off
when the relays de-energi to rest position
操作模式
Operating Modes
单通道操作:输入接线按照VDE 0113-1 及 EN 60204-1标准执行,输入电路中无双回路冗余输入。接地故障将会在急停回路中被检测。
• Single-channel operation: Input wiring
according to VDE 0113-1 and
EN 60204-1, no redundancy in the input
circuit. Earth faults are detected in the
emergency stop circuit.
双通道操作:输入回路中存在冗余重复输入。急停回路中的接地故障及急停按钮相邻成对触点间的短路故障都将被检测。北京外教
• Two-channel operation: Redundancy in the input circuit. Earth faults in the Emergency Stop circuit and shorts across the emergency stop push button are also detected.
自动复位:当输入回路闭合时装置立即被激活。
• Automatic ret: Unit is active as soon as
the input circuit is clod.
2013英语四级改革带监视的手动复位:装置仅在此种情况下被激活---在输入回路闭合前复位回路须断开,并
且在输入回路闭合且延时时间到以后复位回路再次闭合。 这样可以消除因复位按钮越控(指早于输入回路闭合,若此时输入回路闭合后立即断开,会发生自动复位,如果此时输入回路又再次闭合,则会发生安全继电器反复通断,会产生不可预料的后果。笔者认为类似于电力二次回路的防跳)而触发自动复位的可能。
• Manual ret with monitoring: Unit will only
be active if the ret circuit is opened
before the input circuit clos, and the
ret circuit is clod after the input circuit
has clod and the waiting time has
elapd (e technical data). This
eliminates the possibility of the ret
button being overridden, triggering
automatic activation.
• Increa in the number of available contacts
by connection of external contactors/relays.
操作
Operation
Plea note for operation:
装置(使用螺丝压线的端子排)交货时在S11-S12kyp间带有一短路跨接片(双通道输入回路)。
• Unit (screw terminals) delivered with a
bridge between S11-S12 (2-channel input
circuit)
仅13-14/23-24/33-34几对触点是安全触点。41-42仅是辅助触点,可用于显示或指示回路。
• Only the output contacts 13-14/23-24/33-34
are safety contacts. Output contact 41-42 is
an auxiliary contact (e.g. for a display).
为防止触点热熔粘连,保险丝必须被连接在输出触点前面。
• To prevent a welding together of the
contacts, a fu (e technical detail)
must be connected before the output辅导员工作计划
contacts.
• Calculate the max. Cable runs Imax:
____
_______
_____