sales能耗基本估算
ASSUMPTIONS
Total Snowdome area 雪乐园区域:
Cold Area: 25,000 square meters (312 L x 80 W)
冷区:25,000平方米(312米长 x 80米宽)
Warm Area: 9,750 square meters
暖区:9,750平方米
Total Area: 35,700 square meters
合计面积:35700平方米
Building Height: 25 meters from snow surface to ceiling
建筑物高度:25米从雪面到天花板
Hours of Operations:09:00am until 10:00pm (13 hours)
运营时间:09:00AM---10:00pmo(13小时)
Clod: 10:00pm until 09:00am (11 hours)
停止运营:10:00pm---09:00am(11小时)
Snow making Time:11 :00pm---03:00am(4小时,其中2小时造雪)
造雪时间: 11 :00pm---03:00am(4 hours, 2 hours for snow making )
1.Vertical Transport垂直运输
1.1 Travellator (11 degrees)移动毯(11°)
a. 100 meters 100米
Installed capacity: 20KW装机容量:20KW
Drive Capacity: 11KW驱动容量:11KW
b. 200 meter 200米
Installed capacity: 40KW装机容量:40KW
Drive Capacity: 30KW (Double drive 15KW*2) 驱动容量:30KW(双驱动15KW*2)
六人行下载c. 250 meters 250米
Installed capacity: 40KW装机容量:40KW
Drive Capacity: 30KW (Double drive 15KW*2) 驱动容量:30KW(双驱动15KW*2)
●How many kwh while in u 耗费功率
Full loading (driving capacity*10%), the working time is calculated according
to the80% business hours, about 10 hours.
满载功率(驱动容量*10%),工作时间按照营业时间的80%约10小时计算
星期一英语●How many kwh while not in u
No-load Power(driving capacity*10%)
空载功率(驱动容量*10%)
1.2 Chairlift – fixed grip吊椅-固定抱索式
2 pasnger2人
a. 200 meters 200米cleanclear
英语四六级考试报名
b. 300 meters 300米
●How many kwh while in u耗费功率
The unit is 35KW/H and the working time is calculated according to the80% business hours, about 10 hours.
全国英语能力竞赛
标准约35KW/H计算,耗电量按照80%计算,工作时间按照营业时间的80%约10
小时计算
4 pasnger4人
c. 200 meters 200米
d. 300 meters 300米
●How many kwh while in u耗费功率
The unit is 55KW/H and the working time is calculated according to the80% business hours, about 10 hours.
标准约55KW/H计算,耗电量按照80%计算,工作时间按照营业时间的80%约10
小时计算
●How many kwh while not in u 无人时功率
0 (Clod)
1.3 Gondola吊箱
4 pasnger4人
How many kwh while in u耗费功率
The unit is 35KW/H and the working time is calculated according to the80% business hours, about 10 hours.
标准约35KW/H计算,耗电量按照80%计算,工作时间按照营业时间的80%约10小时计算
urban fox2.Air-conditioner 空调
2.1 Warm Area Air-conditioner暖区空调
(采用总装机制冷量4000KW制冷机组(制冷量与用电量比例约3:1))
what is the hourly consumption for: 每小时消耗回应英文
o refrigerant制冷剂
Generally, every 3 years to add refrigerant
按照一般情况,每3年补充一次制冷剂。圣诞节英文祝福语
o water水
Cooling Water CMH= refrigerating output(KW) x 0.224=4000 x
0.224=896 m³/hour
冷却水量CMH=制冷量(KW)X 0.224=3000 x 0.224=672立方米/小时
o electricity电
Operation refrigerant output*70%/3=4000*70%/3=700KW
正常运营总制冷量*70%/3=3000*70%/3=700KW
Snow making(-8°)refrigerant output*70%/3=4000*80%/3=400KW
非运营总制冷量*40%/3=3000*40%/3=400KW
运营时间13小时,非运营时间11小时
2.2 Cold Area Air-conditioner冷区空调
Refrigeration制冷
Temperature is minus 2 degree Celsius from 08:00am until 11:00pm each day
(15 hours)
温度是零下2摄氏度,从08:00am---11pm(15小时)
石家庄播音主持培训Temperature is minus 8 degrees Celsius from 11:00pm until 08:00 each day (9 hours)
温度是零下8摄氏度,从11:00pm点到8:00am(9小时)
The 4000KW refrigeration equipment will be ud.
采用总装机制冷量4000KW制冷机组(制冷量与用电量比例约3:1)