cacl 数控制冷液自动抽空加液机
CA-788C digital control automatic fluid station
CA-788C-600a-N
操作手册
l
牛津大学公开课
c
a
c
绍兴西爱西尔数控科技有限公司shaoxing cacl digital control technology co;ltd
目录
CONTENTS PAGE
使用前Before Using 3 1 设备的组成Equipment components 5 2 加液机主要技术参数Main technology parameter 6 3 使用前的准备Preparation 6 4 常用操作Operating 9 5 自动运行 Aut o ma ti c mo v e me n t 13
6 工作压力Working pressure 16
7 制冷剂用尽的提示 Clew of refrigerant u up 16
autumn是什么意思中文8 测试罐操作规程 Operation rules 17
9 设备维护 Eqipment maintenance 18 10 简单故障排除 Simple trouble shooting 18 11 设备成套性 Complete t of equipment 20 12 设备维修 Equipment maintenance 20
附录 数控制冷液自动抽空加液机的快捷操作
c a四级英语听力下载
c l
使用前Before Using
感谢您使用我公司生产的系列数控制冷液抽空加液机设备(以下简加液机),使用前请仔细阅读说明书并妥善保管,以便需要时查阅。
Thanks for using our production, plea read instruction carefully And keep it properly.
警 告!为使您能够更方便、准确、安全的使用操作该产品,请您务必仔细阅读此说明书。
Warning! Plea read instruction carefully in order to operate this machine more conveniently ,accurately and safely.
安全性Safety
警 告!制冷剂为高压冷媒,有泄漏、燃烧、爆炸、冻伤、中毒、窒息
的危险!操作时必须按规程要求!
Warning! The refrigerant is a kind of high pressure media, it ’s easy to leak, burnt, explode, freeze,
poison and asphyxiate. Plea do operate it as required.
警 告!在R600a 作业时,焊接操作台必须远离加液机5米以上!以避
免火源引起燃烧和爆炸!
Warning! When operate R600a,joingting should away from fuild station at least 5 meters to avoiding fire and explode
警 告!严禁操作车间内吸烟,和其余火种!
Warning! Smoking and other fire in workshop are forbidden.
警 告!请为加液机作必要隔离,配套24小时连续运转的排风设施和
报警装置。
Warning! Plea keep liquid-adding machine insulated with good ventilation establishment.
警 告!制冷剂的排放和泄漏会受到有关制约,应核准获取使用权。
Warning! Refrigerant ’s vent and leak will be restricted, plea check get the right of u.
c a
c l
英语日常口语对话警 告!请确认地线确实已连接妥当。未采取入地措施的设备会存在危
stopwatch险!并且静电会导致、燃烧、爆炸!
Warning! Plea make sure wire is connected properly, otherwi will be danger. Further more , static will arou electric shock, fire, explode!
警 告!流水线相关的各类电器及开关的火花会导致制冷剂的燃烧和
爆炸!必须注意隔离!
becWarning! The spark of any kinds of electric machine which is related to pipeline and swift will cau refrigerant burning and exploding. Plea parate it.
警 告!报警器必须每天24小时运行!应定期检查是否异常,发现
报警检查属于哪个探头,排除故障放可启动主机!
Warning! Annunciator should run 24 hours! Should check it very often to discover which probe is abnormal, after trouble removal then can start machine.
警 告!通风系统必须每天24小时运转!查看电源是否正常,风机
是否运转,如没有运转,打开开关,启动风机!
Warning! ventilation system should run 24 hours! Plea check whether the power is normal, fan is running, if not, plea turn on the swift and start fan.
警 告!供液房钢瓶搬运移动时注意!拖动、撞击可能产生的火花会不到长城非好汉英语
引起触发R600a 的爆炸危险,必须小心轻放!
Warning! Plea be careful when moving the steal bottle in fluid providing room. The spark caud by dragging, striking may lead R600a to explode.
警 告!加、供液房任何金属工具器件搬运、移动、拖动、撞击、甩
落时注意!可能产生的火花会引起触发R600a 的爆炸危险!
Warning! Any mental tool in fluid providing room moving, dragging, dropping may lead R600a to explode
警 告!不可触及内置器件,谨防电击、燃烧、爆炸、冻伤的危险。
Warning! Don ’t touch any accessory inside to avoid electricity shocking, burnt, explode, freeze.
警 告!非授权不可拆卸。
Warning! Don ’t disasmble without authorized
c a
c l
1设备的组成
1. 1气体泄漏报警器
R600a 为易燃易爆制冷剂,使用和操作必须按规程要求!同时为预防和尽可能的避免泄漏事故的发生,
设备装备了气体泄漏报警器,型号为MSA9020系列,详细的操作请参阅《MSA 报警系统操作手册》 1.2风压报警器
为保证系统的安全性,本设备安装了风压传感器,当通风系统由于各种原因
引起通风不良时,风压传感器即会报警,同时切断增压站的供应,使设备停止工作。这种现象是:风机的烧毁或没有启动、风管的堵塞等。
1.3 制冷剂供应异常报警器
周丽娜英语在制冷剂供应出现异常时,冷媒供应的报警器会报警,这种现象是: (1) 制冷剂用尽
(2) 制冷剂钢瓶接口出口连接错误(详见3.3.1) (3) 压缩空气中断
(4) 输送管路泄漏或爆裂
1.4通风系统
通风系统是保证设备安全运行的必要装备,务必配套运行!其风机应符合防爆要求,其风量应符合Qmin>Gmax*f/Kperm*LEL*C *T/293 要求
1.5加液机
见2-7章上海哪里有成人英语培训
特点英文1.6增压站 1制冷剂的供应
2压缩空气的要求:0.4-0.7MPa 3安全的要求
1.7集中控制
设备通过集中控制器将加液机、增压站、通风系统、报警系统结合成一套完整的系统
c a
c l