clau (Abschnitt)Mark(if
applicable)
additional requirements
(zusaetzliche Anforderungen)
short information for Laboratory
(kurze Informationen fuer das Labor)
8.9 Marking
DIN VDE
0620-1:2005 For portable multiple socket outlet
卷心菜的营养价值- Nicht hintereinanderstecken (Do not connect after each other)
brethren
- Nicht abgedeckt betreiben (Do not cover when in u)
For portable multiple socket outlet with functional switch, additionally
- Spannungsfrei nur bei gezogenem Stecker (To disconnect Voltage pull the plug)
For adaptordaruma
- Nicht hintereinanderstecken (Do not connect after each other)
10.6.2 DIN VDE
0620-1:2005Side PE contacts are loaded with a torque of 100 0 -5N.cm for 1 min. With the device picture 43.
After this tests probe 4 must be possible to inrt.
This test is conducted on new samples
For fixed socket outlet (16A/250V)
5N/1min 4 times
13.14 socket force test
DIN VDE 0620-1:2005For fixed socket outlet (16A/250V) 15N/1min 4 times
14.3 DIN VDE
0620-1:2005Earthing contacts and neutral pins of plug: not possible to inrt in an incorrect position
Portable socket outlet having means for suspension shall be so designed that the suspension means do not allow access to live parts
14.18 means for suspension
DIN VDE 0620-1:2005Portable socket outlets with means for permanent mounting shall be tested as fixed outlets with a current acc. to table 20, glow wire test 28.1.1. and additionally for strength to 24.1
Portable accessories shall not be an integral part of lampholders
VDE requirement: Socket with PE and fixed connected plug is not allowed
14.20
DIN VDE 0620-1:2005Portable accessories shall not be an integral part of lampholders Adaptors wit
hout interpod auxiliaries (switches, regulators, timers etc.) shall comply with DIN 49437
入门Multiple outlets with earthing contact and with stiffly mounted plug are not allowed
administrative14.21 In Germany, rewirable plug for class II (2.5A)are not allowed
In Germany, cord extension ts for equipment of class II (16A) are not
allowed
14.27 VDE
make it up
requirement
Cable length should be at least 1.4m
16.2.2 DIN VDE
0620-1:2005Directly after this test the high voltage test 17.2 must be pasd. No water may penetrate in between the insulation and the strands
托福必备词汇19 Temperature ri A plug is inrted into the socket test current is pasd into the socket for 1h Test current: 16A socket with 1.5mm2 cable: 16A
16A socket with 1.0mm2 cable: 12A
The temperature ri of the terminal(L/N/PE) shall not exceed 45K
VDE requirement:
test current: 1) 16A socket cable, 20A
2) 2.5A socket, 10A
If with switch, switch shorted 20A, switch “ON” 16A Test on the socket with lightest cable.
DIN VDE 0620-1:2005* The switch will never be short circuited during the test!
* 1. Test current with rated current
- 16 A for portable socket outlet
Temperature ri of terminals or connections on the additional function not exceed values of requirements of the relevant standards but not more than 70K.
All other connections not exceed 45 K.
儿童节 英文
Test duration: until steady conditions
* 2. Test current with value of table 20
- 20 A for portable socket outlet
Temperature ri of terminals from the additional function not exceed 70 K.
Temperature ri on all other connections not exceed 45 K.
Test duration: 1h
* Temperature ri on touchable metal parts not exceed 40 K and on touchable not metal covers not exceed 60 K
23.2 pull test DIN VDE
0620-1:2005The accessory is conditioned at 450C for 1h. Directly there after (while hot) a pull test is conducted with 50N for 30s, The anchorage shall remain functional but displacement of the cord may exceed 2mm. Thereafter the samples are cooled for the further tests below
d是什么意思Tinl cords or flexible cable with 0.5mm2 are allowed in length up to 2m VDE requirement
flexible cable with 1.0mm2 are allowed in length up to 2m
23.3
DIN VDE 0620-1:2005Non-rewirable plugs rated 16A/250V are tested: 1mm2 and 1.5mm2 at 16A/20A
24.2 barrel turning test DIN VDE
0620-1:2005
Socket-outlets with shutters shall be tested again with the shutter test in
英语四级写作技巧Clau 21
24.9 falling DIN VDE
0620-1:2005Socket-outlets with shutters shall be tested again with the shutter test in Clau 21
28.1 resistance to abnormal heating (glow-wire test) DIN VDE
0620-1:2005
Note 5: The outer material by moulded plugs is totally removed when
testing the supporting parts
31.2 DIN VDE
0620-1:2005Accessories with electronic parts must comply with the relevant EMC requirements