8592L频谱仪参数

更新时间:2023-07-20 19:11:35 阅读: 评论:0

Agilent 8590L-Series
Portable Spectrum Analyzers
Product Overview
Low-Cost General Purpo RF or
MW Spectrum Analysis with
Frequency Accuracy
Frequency Accuracy with Built-In Frequency Counter
With the 8590L and 8594L you get
±7.6 kHz marker count accuracy at 1 GHz. And with the 8592L you get ±165 kHz at 22 GHz. At lower fre-quencies you achieve even greater accuracy.
Additional Features and Options Whether you operate the analyzer manually or remotely, more than 200 functions are available. The Agilent 8590L-Series gives you a full t of marker funtions including
marker delta, marker peak arch, and up to four on-screen markers. Time and date functions are uful for unat-
tended operation and for data storage
or output labels.
Data storage can be to internal mem-
ory, where over 50 traces and states
may be saved, or to memory cards
through the optional memory-card
reader. Data can be directly output to
a printer or plotter through the
optional GPIB, RS-232, or parallel
printer interfaces.
Built-in Measurement Capability
Third-order intercept, percent AM,
and “N” dB bandwidth are just a few
of the built-in measurements. The
measurements are performed at the
press of a single softkey. Results are
displayed onscreen. And the down-
loadable program (DLP) capability
lets you write your own built-in meas-
urements using the DLP editor and
an external keyboard.
Economical and Reliable Solutions with Frequency Accuracy
2
Measurement Personalities Measurement personalities are appli-cation-specific DLPs that are loaded into the analyzer through the optional card reader. They provide measure-ment routines and a ur-interface specific to the application. A scalar measure-ments personality cus-tomizes the 8590L with optional built-in 1.8 GHz tracking generator, and a cable TV measurements person-ality equips the 8590L-Series with one-but-ton RF measurements for CATV rv-ice and system monitoring.Agilent 8590E Series Spectrum
Analyzers
If you need higher performance, more
features, a wider range of options and
upgrade capabilities, or additional
application-bad measurement per-
sonalities than the 8590L-ries pro-
vides, plea contact your local
Agilent Technologies sales office for
information on the 8590E-ries of
portable spectrum analyzers.
MIL-T-28800 Conformance
The 8590 ries spectrum analyzers
conform to the environ-mental specifi-
cations of MIL-T-28800 class 5 to
insure reliable and accurate perform-
ance in portable environments as well
as indoors. Compliance with thecatalog
MIL-T-28800 standards of vibration,
tempera-ture, humidity, and shock pro-
vide assurance that the 8590 ries will
withstand the rigors of field u.
ISO 9000
This product is manufactured in
an ISO 9002 registered facility in
concurrence with Agilent’s quality
commitment.
Perform continuous tests
idea pocketwith built-in measurements
such as percent AM
Position up to four onscreen
markers anywhere on the
trace data
3
Frequency Specifications
Frequency Range
8590L
50Ω9 kHz to 1.8 GHz
75Ω(Opt.001)  1 MHz to 1.8 GHz
8592L9 kHz to 22 GHz
8592L (Opt. 026/027)9 kHz to 26.5 GHz
Band LO Harmonic = N
019 kHz to 2.9 GHz
11  2.75 kHz to 6.5 GHz
22  6.0 GHz to 12.8 GHz
3312.4 GHz to 19.4 GHz
4419.1 GHz to 22.0 GHz
4  4 (Opt. 026/027)19.1 GHz to 26.
5 GHz
8594L
dc coupled9 kHz to 2.9 GHz
ac coupled100 kHz to 2.9 GHz
Frequency Reference
Aging±2 x 10–6/year
Temperature Stability±5 x 10–6
Initial Achievable Accuracy±0.5 x 10–6
Frequency Readout Accuracy
(Start, Stop, Center, Marker)±(freq. readout x freq. ref. error2
+ span accuracy + 1% of span +
20% of RBW + 100 Hz x N1)
Marker Frequency Counter Accuracy
古埃及文字翻译Span ≤10 MHz x N1±(marker freq. x freq. ref. error2
+ counter resolution + 100 Hz x N1) Span >10 MHz x N1±(marker freq. x freq. ref. error2
+ counter resolution + 1 kHz x N1) Counter Resolution
Span ≤10 MHz x N1Selectable from 10 Hz to 100 kHz Span >10 MHz x N1Selectable from 100 Hz to 100 kHz Frequency Span
Range
8590L0 Hz (zero span), 10 kHz to 1.8 GHz 8592L0 Hz (zero span), (10 kHz x N1) to 19.25 GHz 8594L0 Hz (zero span), 10 kHz to 2.9 GHz Resolution Four digits
Accuracy
Span ≤10 MHz x N1±2% of span
Span >10 MHz x N1±3% of span
Frequency Sweep Time
Range20 ms to 100 s
百度英语翻译Accuracy±3%
Sweep Trigger Free Run, Single, Line, Video, External Resolution Bandwidth  1 kHz to 3 MHz (3 dB) in 1, 3, 10
quence. 9 kHz and 120 kHz (6 dB)
EMI bandwidths.
Accuracy±20%
Selectivity
–60 dB/–3 dB
3 kHz to 10 kHz15:1
100 kHz to 3 MHz15:1
1 kHz, 30 kHz16:1Video Bandwidth Range30 Hz to 1 MHz in 1, 3, 10 quence Stability
Noi Sidebands (1 kHz RBW, 30 Hz VBW and sample detector)
>10 kHz offt from CW signal≤–90 dBc/Hz + 20 Log N1
>20 kHz offt from CW signal≤–100 dBc/Hz + 20 Log N1
>30 kHz offt from CW signal≤–105 dBc/Hz + 20 Log N1
System-Related Sidebands
>30 kHz offt from CW signal≤–65 dBc + 20 Log N1
Comb Generator Frequency
8592L100 MHz fundamental frequency Accuracy±0.007%
Amplitude Specifications
Amplitude Range
8590L, 8592L, 8594L Displayed Average Noi Level to +30 dBm 8590L (Opt. 001)Displayed Average Noi Level to +75 dBmV Maximum Safe Input Level(Input attenuator ≥10 dB)
clearbothAverage Continuous Power+30 dBm (1 W)
8590L (Opt. 001)+75 dBmV(0.4 W)
Peak Pul Power
8590L+30 dBm (1 W)
8590L (Opt. 001)+75 dBmV (0.4 W)
8592L, 8594L+50 dBm (100 W) for <10 µs pul width
scnuand <1% duty cycle, input attenuation
≥30 dB
dc
8590L25 Vdc
8590L (Opt. 001)100 Vdc
8592L0 Vdc
8594L0 V (dc coupled)
50 V (ac coupled)
Gain Compression
>10 MHz≤0.5 dB (total power at input mixer3
= –10 dBm)
Displayed Average Noi Level
(Input terminated, 0 dB atten., 30 Hz VBW, 1 kHz RBW, sample detector) 8590L
400 kHz to 1.5 GHz≤–115 dBm
1.5 GHz to 1.8 GHz≤–113 dBm
8590L (Opt, 001)
1 MHz to 1.5 GHz≤–63 dBmV
葛泓语1.5 GHz to 1.8 GHz≤–61 dBmV
8592L
400 kHz to 2.9 GHz≤–112 dBm
2.75 GHz to 6.5 GHz≤–114 dBm
6.0 GHz to 12.8 GHz≤–102 dBm
12.4 GHz to 19.4 GHz≤–98 dBm
19.1 GHz to 22 GHz≤–92 dBm
8592L (Opt. 026)
19.1 GHz to 26.5 GHz≤–87 dBm
8594L
400 kHz to <5 MHz≤–107 dBm
5 MHz to 2.9 GHz≤–112 dBm
Specifications
All specifications apply over 0°C to +55°C. The analyzer will meet its specifications after 2 hours of storage at a constant temperature, within the operating temperature range, 30 minutes after the analyzer is turned on, and after CAL FREQ and CAL AMPTD (and for the 8592L CAL YTF) have been run.
1. N = LO harmonic. N = 1 for 8590L and 8594L
2. Frequency reference error = (aging rate x period of time since adjustment + initial
achievable accuracy + temperature stability)
3. Mixer Power Level (dBm) = Input Power (dBm) –Input Atten. (dB)
四六级准考证查询系统
4
Spurious Respons
Second Harmonic Distortion
5 MHz to 1.8 GHz (8590L)<–70 dBc for –45 dBm tone at input mixer3 10 MHz to 2.9 GHz (8592L)<–70 dBc for –40 dBm tone at input mixer3 >10 MHz (8594L)
>2.75 GHz (8592L)<–100 dBc for –10 dBm tone at input mixer3
(or below displayed average noi level) Third Order Intermodulation
Distortion
>5 MHz to 1.8 GHz (8590L)<–70 dBc for two –30 dBm tones at
suicide squad>10 MHz (8592L, 8594L)input mixer3and >50 kHz paration Other Input Related Spurious
≤1.8 GHz (8590L)<–65 dBc at ≥30 kHz offt, for
≤2.9 GHz (8594L)–20 dBm tone at input mixer3
≤18 GHz (8592L)
≤22 GHz (8592L)<–60 dBc at ≥30 kHz offt, for
–20 dBm tone at input mixer3 Residual Respons(Input terminated and 0 dB attenuation)
1 MHz to 1.8 GHz (8590L Opt. 001)<–38 dBmV
150 kHz to 1.8 GHz (8590L)<–90 dBm
150 kHz to 6.5 GHz (8592L)<–90 dBm
150 kHz to 2.9 GHz (8594L)<–90 dBm
Display Range
Log Scale              0 to –70 dB from ref. level is calibrated;
0.1, 0.2, 0.5 dB/division and 1 to 20 dB/
division in 1 dB steps; eight divisions
displayed
Linear Scale            Eight divisions
Scale units            dBm, dBmV, dBµV, V, and W
Marker Readout Resolution0.05 dB for log scale
0.05% of ref. level for linear scale Reference Level
Range  same as amplitude range Resolution 0.01 dB for log scale 0.12% of ref. level for
linear scale
Accuracy ±0.3 dB @ –20 dBm
0 dBm to –59.9 dBm      ±(0.3 dB + 0.01 x dB from –20 dBm) Frequency Respon(10 dB input attenuation)
8590L Absolute4Relative Flatness5
9 kHz to 1.8 GHz        ±1.5 dB      ±1.0 dB
8592L Prelector peaked in band > 0
Absolute4Relative Flatness5
9 kHz to 2.9 GHz        ±1.5 dB    ±1.0 dB
2.75 GHz to 6.5 GHz      ±2.0 dB    ±1.5 dB
6.0 GHz to 12.8 GHz      ±2.5 dB  ±2.0 dB
12.4 GHz to 19.4 GHz    ±3.0 dB ±2.0 dB
19.1 GHz to 22 GHz      ±3.0 dB  ±2.0 dB
19.1 GHz to 26.5 GHz±5.0 dB  ±2.0 dB
8594L(dc coupled prelector peaked)
Absolute4Relative Flatness5
9 kHz to 2.9 GHz±1.5 dB  ±1.0 dB
Calibrator Output
Amplitude –20 dBm ±0.4 dB
8590L Opt .001+28.75 dBmV ±0.4 dB Resolution Bandwidth
Switching Uncertainty
(Referenced to 3 kHz RBW, at  ref. level )
3 kHz to 3 MHz RBW                ±0.
4 dB
1 kHz RBW                        ±0.5 dB
Linear to Log Switching±0.25 dB at ref. level
Display Scale Fidelity
Log Maximum Cumulative
0 to –70 dB from ref. level  ±(0.4 dB + 0.01 x dB from ref. level) Log Incremental Accuracy
0 to –60 dB from ref. level±0.4 dB/4 dB
Linear Accuracy              ±3% of ref. level
Option Specifications
Option 010 and 011 Tracking Generator (Agilent 8590L only) Frequency Range
(Opt. 010)100 kHz to 1.8 GHz
(Opt. 011)    1 MHz to 1.8 GHz
Output Level
Range
(Opt 010)0 to –15 dBm
(Opt. 011)  +42.8 to –27.8 dBmV
Resolution 0.1 dB
Absolute Accuracy
(@ 300 MHz, –10 dBm)±1.5 dB
(@ 300 MHz, +38.8 dBmV)±1.5 dB
white food
Vernier
Range  15 dB
Accuracy  ±1.0 dB
Output Flatness±1.75 dB
Spurious Output
Harmonic Spurs<–25 dBc
(0 dBm/+ 42.8 dBmV Output)
Nonharmonic Spurs  <–30 dBc
Dynamic Range(Characteristics)
Dynamic Range6TG Feedthrough (Opt. 010)  106 dB  ≤–106 dBm (Opt. 011)  100 dB ≤–57.24 dBmV Power Sweep
Range–15 dBm to 0 dBm
(Opt. 011) +27.8 dBmV to 42.8 dBmV Resolution  0.1 dB
4.Referenced to 300 MHz CAL OUT
5.Ref. to midpoint between highest and lowest freq. respon deviations