electron
NOT MEASUREMENT
SENSITIVE
MIL-STD-1916first
1 April 1996
DEPARTMENT OF DEFENSE
TEST METHOD STANDARD
DOD PREFERRED METHODS
FOR ACCEPTANCE OF PRODUCT
ianAMSC N/A AREA Q CIC DISTRIBUTION STATEMENT A. Approved for public relea; distribution is unlimited.
F O R E W O R D
1.This Military Standard is approved for u by all Departments and Agencies of the Department of Defen (DoD).
2.Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of u in improving this document should be addresd to: Commander, U.S. Army Armament Rearch, Development and Engineering Center, ATTN: AMSTA-AR-EDE-S, Picatinny Arnal, NJ 07806-5000, by using the lf-addresd Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter.
3.DoD procurement practices encourage industry innovation and provide flexibility to achieve the benefits of continuous improvement.
4.There is an evolving industrial product quality philosophy that recognizes the need for quality policy changes that will provide defen contractors with opportunities and incentives toward improv
ement of product quality and cooperative relationships between the contractor and the Government.
5.Process controls and statistical control methods are the preferable means of preventing nonconformances, controlling quality, and generating information for improvement. An effective process control system may also be ud to provide information to asss the quality of deliverables submitted for acceptance. Suppliers are encouraged to u process control and statistical control procedures for their internal control and to submit effective process control procedures in lieu of prescribed sampling requirements to the Government for approval.
6.Sampling inspection by itlf is an inefficient industrial practice for demonstrating conformance to the requirements of a contract and its technical data package. The application of sampling plans for acceptance involves both consumer and producer risks; and incread sampling is one way of reducing the risks, but it also increas costs. Suppliers can reduce risks by employing efficient process with appropriate process controls. To the extent that such practices are employed and are effective, risk is controlled and, conquently, inspection and testing can be reduced.
7.The following points provide the basis for this standard:
a.Contractors are required to submit deliverables that conform to requirements and to
generate and maintain sufficient evidence of conformance.
b.Contractors are responsible for establishing their own manufacturing and process
controls to produce results in accordance with requirements.
c.Contractors are expected to u recognized prevention practices such as process
controls and statistical techniques.
8.This standard also provides a t of sampling plans and procedures for planning and conducting inspections to asss quality and conformance to contract requirements. This standard complies with the DoD policy of eliminating acceptable quality levels (AQL's) and associated practices within specifications.
C O N T E N T S
PARAGRAPH PAGE 1.SCOPE (1)
1.1Scope (1)
1.2Applicability (1)
1.3Applications (1)
1.4Product requirements (1)
1.5Limitations (2)
2.APPLICABLE DOCUMENTS (3)
2.1General (3)
2.2Non-Government publications (3)
2.3 Order of precedence (4)
3.DEFINITIONS (5)
成人用英语怎么说
3.1Acronyms ud in this standard (5)
3.2Acceptance (5)
3.3Contract quality requirements (5)
3.4Critical characteristic (5)
3.5Critical nonconforming unit (5)
3.6Government contract quality assurance (6)
3.7Inspection (6)
3.8Major characteristic (6)
3.9Major nonconforming unit (6)
3.10Minor characteristic (6)
3.11Minor nonconforming unit (6)
3.12Nonconformance (6)
3.13Nonconforming unit (6)
3.14Production inter val (6)
3.15Quality (6)
3.16Quality assurance (6)
3.17Quality audit (6)
3.18Quality program (6)
conquently造句3.19Screening inspection (7)
3.20Traceability (7)
3.21Verification level (VL) (7)
4.GENERAL REQUIREMENTS (8)
4.1Acceptance by contractor-propod provisions (8)
4.1.1General (8)
4.1.2Requirements and procedures (8)
C O N T E N T S
PARAGRAPH PAGE 4.1.3Submission and incorporation (9)
4.1.3.1Submission (9)
4.1.3.2Incorporation (9)
4.1.4Withdrawal of approval of alternates (9)
4.2Acceptance by table s (9)
4.2.1Preferred sampling plans (9)
4.2.2Formation and identification of lots or batches (9)
4.2.3Determination of sampling plan (10)
4.2.4Sampling of lots or batches (10)
儿童学习网
4.2.4.1Selection of units (10)
4.2.4.2Reprentative (stratified) sampling (10)
4.2.4.3Process of sampling (10)
4.2.4.4Non-conforming product (10)
genital
4.3Disposition of n onconforming product (11)
4.4Critical characteristics (11)
4.5Special rervations for critical nonconformance (11)
5.DETAILED REQUIREMENTS (12)
5.1Acceptance by contractor propod-provisions (12)
5.1.1Quality system plan (12)
5.1.2Prevention-bad quality system (12)
5.1.3Process focus of quality system (12)
(13)
btob是什么意思5.1.4Objective evidence of quality system implementation and effectiveness
5.1.4.1Examples of evidence regarding process improvement (13)
5.1.4.2Examples of evidence regarding process control (13)
5.1.4.3Examples of evidence regarding product conformance (14)
5.2Acceptance by tables (14)
5.2.1Sampling inspection (14)
5.2.1.1Verification level specification (14)
aptech5.2.1.2Sampling procedures (15)
5.2.1.3Switching procedures (15)
5.2.1.3.1Normal to tightened (15)
5.2.1.3.2Tightened to normal (16)
5.2.1.3.3Normal to reduced (16)
5.2.1.3.4Reduced to normal (16)
5.2.1.4Discontinuation of acceptance (16)
5.2.2Preferred sampling inspection tables (17)
5.2.2.1Attributes sampling plans for lot or batch inspection (17)
5.2.2.1.1Acceptability criterion (17)
C O N T E N T S
PARAGRAPH PAGE 5.2.2.2Variables sam pling plans for lot or batch inspection (17)
5.2.2.2.1Limitations on u (17)
5.2.2.2.2Nonconforming unit (18)
5.2.2.2.3Acceptability criteria (18)
5.2.2.3Continuous attributes sampling inspection plans (20)
5.2.2.3.1Conditions for continuous sampling procedures (20)
5.2.2.3.2Continuous sampling inspection procedure (21)
5.2.2.3.3Acceptability criterion (21)
5.2.2.3.3.1Special rervation for critical nonconforming unit (21)
奥斯卡影片6.NOTES (22)
6.1Intended u (22)
6.2Issue of DoDI SS (22)
6.3Superssion data (22)
6.4Subject term (keyword listing) (22)
TABLE
I Code letters (CL) for entry into the sampling tables (15)
II Attributes sampling plans (17)
III Variables sampling plans (19)
IV Continuous sampling plans (20)
APPENDIX Examples of sampling plan u (23)
FIGURE
1Attributes sampling inspection log (24)
2Computations for single specification limit ca (25)
3Computations for double specification limit ca (26)
4Continuous sampling inspection log (27)
5Procedure to determine a valid f (28)
CONCLUDING MATERIAL (29)