PowerEdge M1000e Error Messages
The following tables show the possible error messages and their caus that may be obrved from either the front panel LCD or the Chassis Management Controller (CMC) System Event Logs (SEL).
CMC Status Screens
Severity
Message
Cau
Critical
CMC <number> Battery: Battery nsor for CMC, failed was asrted
CMC CMOS battery is missing or no voltage
Critical
CMC <number> CPU Temp: Temperature nsor for CMC, failure event
CMC CPU temperature exceeded the critical threshold.
Critical
CMC <number> Ambient Temp: Temperature nsor for CMC, failure event
CMC Ambient temperature exceeded the critical threshold.
Enclosure/Chassis Status Screen
Severity
Message
Cau
Critical
Chassis Fan <number> Prence: Fan nsor for Chassis Fan, device removed was asrted
This fan is required for proper cooling of the enclosure/chassis.
Warning
Power Supply Redundancy: PS Redundancy nsor for Power Supply, redundancy degraded was asrted
One or more PSU have failed or removed and the system can no longer support full PSU redundancy.
Critical
Power Supply Redundancy: PS Redundancy nsor for Power Supply, redundancy lost was asrted
One or more PSU have failed or removed and the system is no longer redundant.
Critical
Power Supply Redundancy: PS Redundancy nsor for Power Supply, non-redundant: insufficient resources
One or more PSU have failed or removed and the system lacks sufficient power to maintain normal operations. This could cau rvers to power down.
Critical
Control Panel Temp: Temperature nsor for Control Panel, failure event
Chassis/Enclosure temperature exceeded the critical threshold.
Critical
CMC <number> Standalone: Micro Controller nsor for CMC, non-redundant was asrted爱贝导航
CMC no longer redundant. Note: will only show if the standby CMC was removed or failed.
Critical
Chassis Eventlog CEL: Event Log nsor for Chassis Eventlog, all event logging disabled was asrted
The CMC can not log events.
Critical
Chassis Eventlog CEL: Event Log nsor for Chassis Eventlog, log full was asrted
Chassis device detects that only one entry can be added to the CEL before it is full.
Warning
Chassis Eventlog CEL: Event Log nsor for Chassis Eventlog, log almost full was asrted
Chassis event log is 75% full.
Fan Status Screens
Severity
Message
Cau
Critical
新东方在线课程Chassis Fan <number> Status: Fan nsor for Chassis Fan, failure event
The speed of the specified fan is not sufficient to provide enough cooling to the system.
IOM Status Screens
Severity
Message
Cau
Warning
I/O Module <number> Status: Module nsor for I/O Module, transition to non-critical from OK was asrted
The IO module was good, but now having fabric mismatch or link tuning mismatch.
Critical
I/O Module <number> Status: Module nsor for I/O Module, transition to critical from less vere was asrted
The I/O module has a fault. The same error can also happen if the I/O module is thermal-tripped.
iKVM Status Screens
Severity
Message
Cau
Warning
Local KVM Health: Module nsor for Local KVM, transition to non-critical from OK was asrted
Minor failure, such as corrupted firmware.
Critical
Local KVM Health: Module nsor for Local KVM, transition to critical from less vere was asrted
USB host enumeration failure or OSCAR failure
Non-Recoverable
Local KVM Health: Module nsor for Local KVM, transition to non-recoverable was asrted
Serial RIP failure or USB host chip failure
PSU Status Screens
take it to the head成都一对一辅导
Severity
Message
Cau
showergel
Critical
Power Supply PSU <number>: Power Supply nsor for Power Supply, failure was asrted
The PSU has failed
Critical
Power Supply PSU <number>: Power Supply nsor for Power Supply, input lost was asrted
Lost of AC power or AC cord unplugged
Server Status Screens for M600/M605
mtx
Severity
Message
Cau
Warning
System Board Ambient Temp: Temperature nsor for System Board, warning event
Server Ambient temperature crosd a warning threshold
Critical
System Board Ambient Temp: Temperature nsor for System Board, failure event
Server Ambient temperature crosd a failing threshold
Critical
System Board CMOS Battery: Battery nsor for System Board, failed was asrted
CMOS battery is not prent or has no voltage
Warning
System Board Current Monitor: Current nsor for System Board, warning event
Current crosd a warning threshold
heads up 翻译
Critical
System Board Current Monitor: Current nsor for System Board, failure event
Current crosd a failing threshold
edl
Critical
<voltage nsor name>: Voltage nsor for System Board, state asrted was asrted
Voltage out of range
Critical
CPU<number> Status: Processor nsor for CPU<number, IERR was asrted
CPU failure
Critical
CPU<number> Status: Processor nsor for CPU<number>, thermal tripped was asrted
CPU overheated
Critical
CPU<number> Status: Processor nsor for CPU<number, configuration error was asrted
Incorrect processor type or in wrong location
Critical
CPU<number> Status: Processor nsor for CPU<number>, prence was deasrted
Required CPU is missing or not prent
Critical
System Board Video Rir: Module nsor for System Board, device removed was asrted
Required module was removed
Critical
Mezz B Status: Add-in Card nsor for Mezz B, install error was asrted
Incorrect Mezzanine card installed for IO fabric
Critical
Mezz C Status: Add-in Card nsor for Mezz C, install error was asrted
Incorrect Mezzanine card installed for IO fabric
Critical
Backplane Drive <number>: Drive Slot nsor for Backplane, drive removed
Storage Drive was removed
Critical
Backplane Drive <number>: Drive Slot nsor for Backplane, drive fault was asrted
Storage Drive failed
Critical
System Board PFault Fail Safe: Voltage nsor for System Board, state asrted was asrted
This event is generated when the system board voltages are not at normal levels.
Critical
System Board OS Watchdog: Watchdog nsor for System Board, timer expired was asrted
The iDRAC watchdog timer expires and no action is t.
Critical
System Board OS Watchdog: Watchdog nsor for System Board, reboot was asrted
The iDRAC watchdog detected that the system has crashed (timer expired becau no respon was received from Host) and the action is t to reboot.
Critical
bishopSystem Board OS Watchdog: Watchdog nsor for System Board, power off was asrted
The iDRAC watchdog detected that the system has crashed (timer expired becau no respon was received from Host) and the action is t to power off.
Critical
System Board OS Watchdog: Watchdog nsor for System Board, power cycle was asrted
The iDRAC watchdog detected that the system has crashed (timer expired becau no respon was received from Host) and the action is t to power cycle.
Critical
System Board SEL: Event Log nsor for System Board, log full was asrted
The SEL device detects that only one entry can be added to the SEL before it is full.
Warning
ECC Corr Err: Memory nsor, correctable ECC ( <DIMM Location> ) was asrted
Correctable ECC errors reach a critical rate.
Critical
ECC Uncorr Err: Memory nsor, uncorrectable ECC ( <DIMM Location> ) was asrted
An uncorrectable ECC error was detected.
Critical
I/O Channel Chk: Critical Event nsor, I/O channel check NMI was asrted
A critical interrupt is generated in the I/O Channel.
Critical
PCI Parity Err: Critical Event nsor, PCI PERR was asrted
Parity error was detected on the PCI bus.
Critical
PCI System Err: Critical Event nsor, PCI SERR ( <Slot number or PCI Device ID>) was asrted
PCI error detected by device
Critical
SBE Log Disabled: Event Log nsor, correctable memory error logging disabled was asrted
Single bit error logging is disable when too many SBE get logged
Critical
Logging Disabled: Event Log nsor, all event logging disabled was asrted
All error logging is disabled
Non-Recoverable
CPU Protocol Err: Processor nsor, transition to non-recoverable was asrted
The processor protocol entered a non-recoverable state.
Non-Recoverable
CPU Bus PERR: Processor nsor, transition to non-recoverable was asrted
The processor bus PERR entered a non-recoverable state.
bring upNon-Recoverable
CPU Init Err: Processor nsor, transition to non-recoverable was asrted
The processor initialization entered a non-recoverable state.
Non-Recoverable
CPU Machine Chk: Processor nsor, transition to non-recoverable was asrted
The processor machine check entered a non-recoverable state.
Critical
Memory Spared: Memory nsor, redundancy lost ( <DIMM Location> ) was asrted
Memory spare is no longer redundant.
Critical
Memory Mirrored: Memory nsor, redundancy lost ( <DIMM Location> ) was asrted
Mirrored Memory is no longer redundant
Critical
Memory RAID: Memory nsor, redundancy lost ( <DIMM Location> ) was asrted
RAID Memory is no longer redundant
Critical
Memory Cfg Err: Memory nsor, configuration error ( <DIMM Location> ) was asrted
Memory configuration is incorrect for the system.
Warning
Mem Redun Gain: Memory nsor, redundancy degraded ( <DIMM Location> ) was asrted
Memory redundancy is down graded but not lost
Critical
PCIE Fatal Err: Critical Event nsor, bus fatal error was asrted
Fatal error is detected on the PCIE bus.
Critical
Chipt Err: Critical Event nsor, PCI PERR was asrted
Chip error is detected.