PRESCRIPTIVE METHOD FOR RESIDENTIAL COLD-FORMED
STEEL FRAMING
Second Edition
Prepared for
The U.S. Department of Housing
and Urban Development
Office of Policy Development and Rearch
藏语在线翻译Washington, DC
Co-Sponsored by
penny是什么意思The American Iron and Steel Institutecool是什么意思
Washington, DC
and
The National Association of Home Builders
Washington, DC
by
NAHB Rearch Center, Inc.
400 Prince George's Boulevard
Upper Marlboro, MD 20774-8731
August 1997
CONTENTS
5.0 STEEL FLOOR FRAMING (21)
5.1 Floor Construction (21)
5.2 Floor to Foundation or Bearing Wall Connection (21)
5.3 Allowable Joist Spans (21)
5.4 Joist Bracing (21)
5.5 Floor Cantilevers (22)
5.6 Splicing (22)
5.7 Framing of Floor Openings (22)
5.8 Floor Truss (22)
5.0 STEEL FLOOR FRAMING
5.1 Floor Construction
shield是什么意思Cold-formed steel framing members shall comply with the provisions of Section 2.0. Steel floors shall be constructed in accordance with this ction and Figure 5.1.
5.1.1 Applicability Limits
The applicability limits of Section 1.3 and Table 1.1 shall apply.
5.1.2 In-Line Framing.
Load bearing steel floor framing, wall framing, and ceiling/roof framing shall be constructed
in-line with the vertical load bearing members (i.e. studs) located below. A maximum tolerance of 3/4 inch (19 mm) between the centerlines of the in-line members shall be permitted in accordance with Figure 1.2.
5.2 Floor to Foundation or Bearing Wall Connection
Cold-formed steel floor framing shall be anchored to foundations, wood sills, or load bearing walls in accordance with Table 5.1 and Figures 5.1 through 5.10. Fastening of steel joists to other framing members shall be in accordance with Table 5.2.
5.3 Allowable Joist Spans
The clear span of cold-formed steel floor joists shall not exceed the limits t forth in Table 5.3 for single spans and Table 5.4 for multiple spans. When continuous joist members are ud for multiple spans, the interior bearing supports shall be located within two feet (0.6 m) of mid-span of the steel joists, and the individual spans shall not exceed the applicable spans in the table. Floor joists shall have a bearing support length of not less than 1.5 inches (38 mm) for exterior wall supports and 3.5 inches (89 mm) for interior wall supports. Bearing stiffeners shall be installed at each joist bearing location in accordance with Section 2.9. The thickness of joist tracks shall be a minimum of 33 mils (0.84 mm) thick except when ud as part of floor header or trimmer in accordance with Section 5.7.
5.4 Joist Bracing
The top flanges of floor joists shall be laterally braced by the application of floor fastened to the joists in accordance with Table 5.2. Floor joists with spans that exceed 12 feet (3.7 m) shall have the bottom flanges laterally braced in accordance with one of the following:
1. Gypsum board installed with minimum#6 screws in accordance with
the
applicable building code, or
2. Continuous steel strapping installed in accordance with Figure 5.1 and 5.2.
Steel straps shall be at least 1-1/2 inches (38 mm) in width and 33 mils
(0.84 mm) in thickness. Straps shall be fastened to the bottom flange of
电子商务英语词汇each joist with at least one #8 screw and shall be fastened to blocking with
at least two #8 screws. Blocking or bridging (X-bracing) shall be installed
between joists at a maximum spacing of 12 feet (3.7m) measured along the
continuous strapping (perpendicular to the joist run). Blocking or
bridging shall also be located at the termination of all straps.
5.5 Floor Cantilevers
Floor cantilevers for the cond floor of a two-story building or the first floor of a one-story building shall not exceed 24 inches (610 mm) as illustrated in Figure 5.1. Cantilevers shall support interior floor loading only. Cantilevers, not exceeding 24 inches (610 mm) and supporting one floor and roof
(first floor of a two story building), shall be permitted provided that all cantilevered joists are doubled (nested or back-to-back). The doubled cantilevered joists shall extend a minimum of 6 feet (1.8 m) toward the inside and shall be fastened with a minimum of two #8 screws spaced at 24 inches (610 mm) on center through the webs (for back-to-back) or flanges (for nested joists). Approved design is required for cantilevered areas supporting uniform live loads greater than 40 psf (1.92 kN/m2).
5.6 Splicing
Joists and other structural members shall not be spliced without an approved design. Splicing of tracks shall conform with Figure 5.11.
5.7 Framing of Floor Openingsrelaxing是什么意思
Openings in floors shall be framed with header and trimmer joists. Header joist spans shall not exceed 8 feet (2.4 m) in length. Header and trimmer joists shall be fabricated from joist and track ctions, which shall be of a minimum size and thickness as the adjacent floor joists and shall be installed in accordance with Figures 5.1, 5.12, and 5.13. Each header joist shall be connected to trimmer joists with a minimum of four 2 inch x 2 inch (51 mm x 51 mm) clip angles. Each clip angle shall be fastened to both the header and trimmer joists with four #8 screws evenly spaced on each le
g of the clip angle. The clip angles shall have a thickness not less than that of the floor joist.
5.8 Floor Truss
Cold-formed steel floor truss shall be designed, braced, and installed in accordance with an approved design. Truss members shall not be notched, cut, or altered in any manner unless by an approved design. All truss shall be aligned with load carrying members (i.e. studs) in the wall. Refer to AISI publication RG-9518 [17] “Design Guide For Cold-Formed Steel Truss” for additional guidance.
Table 5.1
For SI: 1 inch = 25.4 mm, 1 psf = 0.0479 kN/m2, 1 mph = 1.61 km/hr, 1 foot = 0.3m. 1U the highest of the wind speed and exposure or the ismic requirements for a given site.
2All screw sizes shown are minimum
Table 5.2
Floor Fastening Schedule1
For SI: 1 inch = 25.4 mm
impunity
1All screw sizes shown are minimum.
2 Head styles shall be bugle-head, flat-head, or similar with a minimum head diameter of 0.29 inch
(7 mm).
Allowable Spans For Cold-Formed Steel Floor Joists1,2,3,4
Single Span
33 ksi Steel
For SI: 1 inch = 25.4 mm, 1 psf = 0.0479 kN/m2, 1 foot = 0.3m.
硫怎么读
1Table provides the maximum clear span in feet and inches.
2Bearing stiffeners shall be installed at all support points and concentrated loads. 3Deflection criteria: L/480 for live loads; L/240 for total loads.
4Floor dead load = 10 psf (0.479 kN/m2)
5 For actual size refer to Table 2.1.
Allowable Spans For Cold-Formed Steel Floor Joists1,2,3,4,5,6
Multiple Spans
33 ksi Steel
呼啸山庄英文读后感
For SI: 1 inch = 25.4 mm, 1 psf = 0.0479 kN/m2, 1 foot = 0.3m.
1 Table provides the maximum clear span in feet and inches to either side of the interior support.
2Interior bearing supports for multiple span joists shall consist of structural (bearing) walls or beams.
3Bearing stiffeners shall be installed at all support points and concentrated loads.
4Deflection criteria: L/480 for live loads; L/240 for total loads.
5Floor dead load = 10 psf (0.479 kN/m2)adam lamberg
6Interior supports shall be located within two feet (610 mm) of mid span provided that each of the resulting spans does not exceed the appropriate maximum span shown in the table above.
7For actual size refer to Table 2.1.
冷弯型钢框架结构设计⽅法
第⼆版
为美国住房发展政策开发部门和华盛顿研究中⼼所准备
由美国华盛顿钢铁研究所联合主办
国家建筑协会,华盛顿
NAHB研究中⼼,乔治王⼦的⼤道400号Marlboro.MD 20774-8731

本文发布于:2023-06-19 20:56:50,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/90/150854.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:华盛顿   设计   型钢
相关文章
留言与评论(共有 0 条评论)
   
验证码:
Copyright ©2019-2022 Comsenz Inc.Powered by © 专利检索| 网站地图