清洗部分
1. A plywood floor has breakage of the outer veener. In which ca would this condition be allocated as wear and require repair?
A. evidence of delamination with signs of impact
B. no evidence if delamination or impact
C. no evidence of delamination with signs of impact
D. evidence of delamination with no signs of impact
2. What is the maximum dent allowed on an open top container corner protection plate and rear header extension plate?
A. 50MM
B. 25MM
普通英文
C. 15MM
D. 10MM
3slowdance. The roof of a container has sustained some damage. Which of the
following items doe NOT require repair?
A. broken weld on left side
B. dent measuring 30mm
C. bayonet puncture in the corner protection plate
D. roof bow distorted 60mm
4. What component code should be ud for a plywood foolr?
exo什么意思A. FPP
B. PLY
C. FSP
2014年山东高考录取分数线D. FTP
5. Wwhetherorhich of the following defects on a container floor does NOT require repair?
A. a corroded, stiff locking bar
ingressB. a loo gasket that is light-tight
C. a 30mm door panel dent
D. a missing locking bar guide
6. C奥斯卡获奖金曲omponent X in the diagram above is the ?
A. threshold plate
B. rear sill
C. gooneck tunnel plate
D. hat ction center spacer
7. Component Y in the diagram is the ?
A. side panel
B. rear sill
C. top rail
D. crossmembers
8. In the figure above, a reference line has been ‘spaced out’ from the corner fitting to determine if the corner post bulge is out of ISO. The spacer to be ud in this situation must be a minimum thickness of
A. 3mm
B. 5mm
C.8mm
D. 10mm
9. Which of the following is true abt repair of roof corner protection plates?
A. repair of plates by straightening and welding is not permitted.
B. if the plates can’t be straightened, they may be repaired with an inrt.
C. plates may extend 150mm along the top side and header rails
D. replacement plate material may be 3.2mm thick
10. According to IICL-5 , which one of the following conditions on an open top container requires repair?
A. side panel dent of 25mm
B. roof bow dent of 20mm
C. misaligned grommets
amacD. rusted roof bows
11. Three containers have sustained gouges 10mm deep in their wood floors. Which container need repair, if any, if the widths of the gouges measures as follows:
Container 1, width=75mm
Container 2, width=125mm
Container 3, width=175mm
A. container 3 only
B. container 2 and 3 only
C. container 1,2,3
D. none of the containers’ floors need repair
12. Which of following container defect must be repaired.
A .19mm height difference between adjoin floor panel
B. 25mm deform of the web of the front sill.
fddi
C. 25mm dent on the bottom flange of crossmember
D two dents on opposite inboard corrugations reduce interior cube 25mm
13. A corner post require repair if it has
A a sign dent of 13mm
B two dent of 8mm each
C three dent of 6mm each
D exceed ISO tolerance plus 6mm
14. What dimensions need to assd when measuring a floor gouge
A The length and depth of damage
B The length and width of damage
C The depth and width of damage
日语词典D The depth, length and width of damage
15. The may length of a cut that may be welded is:
A. 75 B. 150 C. 200 D. 300