Description of the Method Developed for Dye Penetrant Analysis of Cracked Solder Joints
Background
The extension of cracks in solder joints after fatigue testing is usually evaluated using cross-ctioning of the solder joints. The printed board asmbly, or a part of it, is potted in epoxy and is then cut clo to the solder joints that will be examined and the sample is ground in to the solder joints. As shown in Figure 1, the formation of cracks in solder joints can be very irregular and vary considerably even in joints located clo to each other.
Figure 1 Photograph showing the extent an irregularity of cracking in solder joints to a BGA after thermal cycling. The cracking has been analyd using a dye
penetrant and the areas coloured red indicate how far the cracks had
propagated during the thermal test.
Thus, to obtain a three-dimensional view of the extension of cracking in a solder joint, polishing must be done in steps while the extension of cracking is successively documented. Just making one cut through a solder joint may give a completing misleading result. For example, if a cut is made from A to B in Figure 1, it would indicate a completely cracked joint whereas a cut from C to D would indicate that almost no cracking has occurred. Furthermore, a number of solder joints need to be examined in order to get statistically valid results. All solder joints in a row can be examined simultaneously. If all solder joints to a BGA shall be examined, this must be repeated for every row of joints. This is a very time consuming and costly process. Furthermore, it is difficult to determine the exact position of a cut.
sanity
怎么锻炼小孩的记忆力As already shown in Figure 1, dye penetrant analysis offers a three-dimensional view of cracks in solder joints to a component. The technique was originally developed by Motorola’s Land Mobile Pro
ducts Sector’s Advanced Manufacturing Technology group [1]. The component asmbled on the printed circuit board was flooded with a dye penetrant liquid to define the cracked area. After having applied the dye, the component was removed by bending the board numerous times. The fractured solder joints were then visually inspected and photographs were made to record the position that dye had penetrated into the joint. This method works well if the cracks in the solder joints are large. If they are not large enough, the pads on the board will rip off from the laminate.
In order to facilitate the removal of components with small cracks in the solder joints, IVF has improved the technique to remove the components in a project funded by ESA [2]. Application of Dye
In order to facilitate the application of the dye, a dam is created around the component using a modelling wax. If there are via holes beneath the component, a tape is applied to the via holes on the opposite side of the board to prevent the dye from escaping through them. If that is not possible, the sample is laid in a glass beaker. The dam is then filled with the dye (Steel Red from DYKEM) or alternatively the dye is poured into the glass beaker until the sample is completely submerged in the dye. The board or the glass beaker is placed in a vacuum chamber and two evacuations are made down to 100 mbar in order to remove any air entrapped in the cracks. Since solvents in the dye evap
广州粤语培训orate during this process, it is done as fast as possible to prevent the viscosity of the dye getting too high. The surplus dye is then poured out and the sample is dried at 100°C for 15 minutes.
Removal of Components
The upper side of the component package is roughened using a grinding paper and is then dried with a cloth wetted with acetone. A steel cylinder with a threaded hole is glued to the component using a two-part epoxy glue, Plastic Padding Super Steel from Loctite (Fig. 2). The steel cylinder is shotblasted in order to improve the adhesion of the glue.iita
The board is then fixed by screws to an aluminium plate with a thickness of 1 cm. A hook is screwed to the steel cylinder and the sample is arranged so that a pulling force can be applied through the hook (Fig. 3). For BGA components having only peripheral joints it may be better to drill a hole through the component and apply a pulling force as shown in Figure 4. The aluminium plate is placed on a heating plate with the heat controlled by a thermocouple attached to the upper side of the board. The temperatures of the solder joints are registered using another thermocouple.潜心贯注的意思
dragon skinA pulling force of about 50 grams per joint is applied to the package. This force caus the solder to creep and the package can be removed without bending the board. If the solder joints are verely c
racked, it may be possible to remove the package within a few hours at room temperature. However, in most cas it is necessary to heat the samples to be able to remove the packages within a reasonable time. The higher temperature, the faster is it possible to remove the component. By heating the solder joints to 140°C, even packages with only small cracks in corner joints can be removed within a few hours. However, at temperatures above 120°, the colour of the dye fades slightly. Also, a good temperature control system is required to ensure that the temperature of the board will not ri above the melting point of the solder when the package becomes loo. If the maximum temperature is limited to 120°C, it may take 10-40 hours to remove a BGA component having about 600 I/Os if the cracks are very small in the solder joints.
北大青鸟培训机构
4311Figure 2. A component with a steel cylinder glued to it
Figure 3. Arrangement for applying a pulling force to a package
Figure 1 Arrangement for applying a pulling force to a BGA by drilling a hole through the component.
Ca Study of DBGA
This example taken from Reference 2 shows how dye penetrant analysis has been ud to evaluate the extent of cracking in solder joints to two thermally cycled Dimple BGA (DBGA) packages.
Test Vehicle
全球化的利与弊The DBGA packages had a body size of 17 x 17 mm and 228 I/Os with a pitch of 1.0 mm. Both pack
ages had daisy chain interconnections. The packages were soldered to a multilayer polyimide/glass board with tin-lead plated pads using vapour pha soldering. A flux was added to promote wetting but no additional solder. One package was soldered to a footprint with round solder pads (Component A) whereas the cond package was soldered to a footprint having pads with a teardrop form (Component CX).
The test vehicle had been thermally cycled in air per ESA-PSS-01-738 with temperature extremes of –55 and +125°C. The cycling was stopped after 500 cycles. The package soldered to the footprint with round pads still functioned electrically after the thermal cycling test but one electrical defect had occurred in one row of I/Os on the other package.
Dye Penetrant Analysis
The extent of cracking in the solder joints to the two DBGA packages was analyd using the procedure for dye penetrant analysis described previously. The solder joints were heated to about 100°C during the removal of the components. At this temperature, the components were removed within 30 minutes.
All solder balls remained on the printed circuit board for both packages. The fractures in the solder jowhisperer
ints were very clo to the component pads for all solder joints (Fig. 5). The majority of the solder joints were verely cracked for both components and to about the same extent (Fig. 6). The fractures in some corner solder joints were coloured completely red (Fig. 7). Thus, although failure had only been registered for Component CX, failure for Component A must have been imminent.
Figure 5. View of solder balls remaining on the PCB after removal of Component CX
Figure 6. Extent of cracking in Component A (a) and to Component CX (b) analyd using dye penetrant
Figure 7. Clo-up of the fracture to corner joints to Component A (a) and to Component CX (b). NP = Neutral Point.
The remaining solder balls on the PCB were broken away at some locations by gripping them with a micro-tweezer and pulling vertically to the board surface. This enabled us to examine the integrity of the joints towards the board pads. In all cas, the pads were ripped off from the laminate. For a connection in the inner row, no fracture in the laminate could be obrved