不良代码 故障定义 检查方法/措施
1-1 System not Enabled or Missing AC Input Pha
系统没有正常工作或输入交流电缺相 外部急停开关开路或CCM板的TB1—1&2的跳线脱落。交流缺相。GCM2000或GCM2010气体控制箱没打开,检查GCM控制电缆的连接,检查电源上的CP4或CP5保险丝,检查气体控制箱F19保险丝。
Plasma Enable Off; External E-Stop Activated or CCM TB1-1&2 jumper missing; Missing AC Pha; No power to GCM 2000 or 2010 Gas Control, check GCM control cable connected, ret CP4 or CP5 circuit breaker in power supply, blown fu F19 in GCM
1-2 Pilot Ignition Failure
引弧失败 Pilot did not start within 15 conds. Preflow pressure too high; Defective Arc Starter
15秒内引弧不成功;预流气体压力过高,高频点火器故障。(
1-3 Lost Pilot
引弧丢失 引弧信号没有关闭,引弧就熄灭了,预流气体压力过高,切割电流设定太低。
Pilot went out without shutoff signal; Preflow pressure too high; cut current t too low for consumables.
1-4 弧转移丢失
showta
Loss of Transfer 50ms内弧转移不成功;初始化定位高度太高,设定电流太低。
Arc transfer (>50 ms.) then arc lost with START still on. Standoff too high; Current t too low.
女阴1-5 电弧偏离了工件
Of the Plate 割炬的移动超过了被切割的金属边缘
Function not currently enabled.
1-6 电弧转移时超时
Pilot Timed out w/o Transfer 弧转移必须在85毫秒(SW8-1  OFF)或3秒(SW8-1  ON)内完成;初始化定位过高或割枪没有在有效的切割范围内,检查是否是易损件损坏引起电流太小;预流气体太低。
Must transfer from Pilot to Cutting Arc in 85 ms. (SW8-1 OFF) or 3 c. (SW8-1 ON). Standoff too high or void in work under torch; cut current too low for consumables; Preflow pressure too low.
1-7 割嘴保护
Tip Saver 功能无效
Function not currently enabled.
1-8 割枪短路tobeginwith
Possible Shorted Torch 电极与喷嘴间的电压太低,等离子流量或压力太低,等离子气体泄漏,切割电流设定太高,割枪主体短路,易损件损坏。
Detected tip voltage too clo to electrode voltage. Plasma flow/pressure too low; Plasma leak; cut current too high;shorted torch body; consumable parts worn out.
2-1 缺相
Missing Pha
nancy travis
保险损坏或三相交流电源中的一相脱落。
abruptBlown fu, Broken or loo connection on power cable
2-2 输入电压不正常
Wrong input voltage 电网供电电压和等离子输入电压要求不同,电源开关不良,输入线径太小,功率因素太低或电力电缆脱落。
Inverter(s) not configured correctly for input voltage; Poor power quality (brownouts, dropouts);Input power capacity / wiring too small causing voltage drop; broken or loo power cable connections.
2-3 逆变器或引弧模块过热
Inverter or Pilot Regulator Over Temperature 风扇损坏,环境温度过高(>40度),通风不良.
Failed fan; Ambient above 40 deg C. (104 F); Blocked airflow
2-4 电源没有准备好
Power Supply not Ready 逆变器损坏。
Defective inverter
2-5 输出的直流电低
DC Output Low 输出电压小于60伏,逆变器损坏,输出短路,引弧模块短路,CCM板电压识别输入(J6)断线或没连接。
Output less than 60 VDC; Defective inverter, shorted output; Shorted pilot regulator (chopper); CCM voltage n (J6)wire open or disconnected.
toyota什么意思
2-6 输入电流过大
Primary over current fault 逆变器输入电流过大。逆变器损坏,关闭电源重新启动;削尖峰电路损坏。
Over current detected in inverter primary circuit, remove power to ret; defective inverter; voltage surge;
2-7 输出电流超出正常值
Unexpected current 在引弧启动之前引弧线和工作电缆中就有>20A电流,割枪短路,电流传感器损坏。
amCurrent >20A in work or pilot leads before pilot ignition; Possible 绯闻女孩第一季土豆shorted torch; Defective current nsor.
2-8 引弧电流异常
Unexpected current in pilot circuit 引弧电流>5A,易损件选择错误,引弧线对枪体短路, 割枪主体短路。
Current > 5A in pilot circuit; wrong or mismatched consumables; Pilot lead shorted to negative in torch tube; Possible shorted torch
clockworkmod2-9 WORK电流异常
Unexpected current in work lead 在启动引弧之前WORK线中电流>5A,高频点火箱短路,负极线对地短路.
Current >5Ain work lead; Short to chassis in RAS; Negative lead short to gnd.
3-1 气体控制箱通讯错误,不能建立连接
Control Communication fault, Cannot establish Communication with gas control. GCM1000:控制线没连接或基本信号开路,其它的气体控制箱:光纤接口脏,用干燥的压缩空气吹干净光纤端口,光纤接口没插牢,光纤弯角太小,光纤损 坏。CCM板或气体控制板损坏。
If GCM 1000: Control cable not connected or Basic ID signal open.GCM 2010 & 2000: Dirt on fiber ends or in connectors, blow out with clean dry air; tiber not locked into connector; sharp bends in fiber; fiber defective; Gas Control PCB defective,replace. CCM defective, replace.
3-2 气体控制通讯应答错误:通讯以连接,但CCM板并收到了应答信号
Gas Control Communication reply fault, connection was established but CCM did receive a reply to a process request 气体控制箱在规定时间内没有给CCM板发出应答信号,光纤接口脏,用干燥的压缩空气吹干净光纤端口,光纤接口没插牢,光纤弯角太小,光纤损坏。气体控制板 损坏。
Gas Control did not reply to signal from CCM in allowed time. Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not locked into connector; sharp bends in fiber; fiber defective. If problem persists Gas Control PCB likely defective, replace board.
3-3 等离子气压低
Gas pressure Low 输入气体气压低或传感器故障
If GCM 1000, Plasma < 15 PSI; faulty or disconnected pressure SW. If GCM2010_AG, GCM2000-AC or later or Gas Control has been updated with 19x2219-AG or later PCB: Plasma or Shield input out of range 105-135 PSI; Unplugged or Faulty pressure nsor.
3-4 气体控制没有准备好
Gas Control not ready 没有排气,控制没有设定到Run状态;气体控制箱故障,更换PCB板。