SIMATIC
STEP 7- Micro/WIN V4.0 SP9
Copyright (c) Siemens Industry Inc., 2011
Contents
Notes on installation
1 Operating system and hardware requirements
2 Operating environment
3 Installation
4 Installing the upgrade licen
Notes on usage
5 What's new
6 Known problems and remedies
6.1Problems
6.2National languages
6.3General communications
6.3.1Multi-master communications
6.4Project compatibility
7 Using the Force function
Notes on installation
1 Operating system and hardware requirements
Microsoft Windows XP SP3 (32-bit only) or Windows 7 (32-bit and 64-bit).
A personal computer (PC) capable of running one of the above operating systems, refer to
Microsoft specifications for more information.
At least 350 Mbytes of free hard disk space
vancl是什么意思
U the small font tting and a minimum screen resolution of 1024x768 pixels
Any mou supported by Microsoft Windows
For communicating with the S7-200 you will need one of the following: –PC/PPI Cable connected to your USB port
–PC/PPI Cable connected to your rial communications port (PC COM1 or COM2) –Communications processor (CP) card and multipoint interface (MPI) cable
–EM241 modem expansion module
–CP243-1 or CP243-1 IT Ethernet expansion module
CP card support for STEP 7_Micro/WIN V4.0SP9 with Windows XP SP3(32_bit) and Windows 7(32_bit and64_bit):
–CP5512 supported
–CP5611 supported
The Set PG/PC Interface device CP5611(PPI) is not supported when installed on Windows 7 64-bit. You may choo the CP5611(MPI) or CP5611(PROFIBUS) as an alternative. The CP5611(MPI) interface may be ud for all baud rates except
9.6 Kbps. The CP5611(PROFIBUS) interface may be ud for all baud rates.
–CP5613 not supported
–CP5614 not supported
PG/PC interface tup with Windows 7 64-bit operating system
The format of the device names in the 64-bit version of the PG/PC interface has
changed from the previous 32-bit PG/PC interface that is described in the system manual and Help topics. In the 64-bit version, the device names take the format of: <Dev ice.Protocol.InstanceNumber
>, where “Device” is the name of the device such as "PC/PPI cable", Protocol is the communications protocol such as "PPI" or "MPI", and “InstanceNumber” is a number (typically 1, unless you have multiple devices of the same type installed).
Installation problems with SIMATIC NET
miryoIf you have SIMATIC NET V6.2 or earlier installed on you computer you may receive the following error during installation.
"Fatal error in SIMATIC NET Component sntieno.dll"
"Installation of protocol siem_isotrans failed with error code hr=0x80070430"
If you experience this error follow the steps:
1. Finish the installation and reboot your PC. Rebooting is required.
2. U Add/Remove Programs to uninstall the software and reboot your PC.
Rebooting is required.
3. Install the software again, this time you will not receive the error.
高级口译Intelligent modules can be placed in any valid module position (if the CPU firmware is version 1.21 or greater). For systems containing earlier CPU firmware that supports intelligent modules, refer to Internet update 9261022. This update for earlier CPU
firmware basically requires all intelligent modules to be located as a group adjacent to the CPU (for example: no discrete or analog module is allowed between the CPU and the group of intelligent modules).
Intelligent modules currently available:
–EM277 PROFIBUS-DP
–EM241 Modem
–EM253 Position
–CP243-1 Ethernet
–CP243-1 IT Internet
网络在线英语培训2 Operating environment
To be able to install and work with STEP 7-Micro/WIN software under Windows XP, you must have logged on with at least power ur privileges.去日本留学的条件
To be able to install and work with STEP 7-Micro/WIN under Windows 7, you must have logged on with administrator privileges.
It is recommended that you disable hibernation mode when using STEP 7-Micro/WIN.
Entering hibernation mode while online connections are open or while projects are being accesd by STEP 7-Micro/WIN through a network can cau the following
errors:
Unintentional termination of online connections
Data loss in any open projects that were opened through a PC network
taoleTo avoid the errors, t the energy saving options for the operating system in the Windows Control Panel to manual trigger. This ensures that hibernation is not
automatically triggered by a timer. Do not manually trigger hibernation mode during a communication task, as described above.
STEP 7-Micro/WIN Version 4.0 SP9 has been tested under the following operating system versions:
Windows XP SP3 (32-bit version)
Windows 7 (32-bit version)
Windows 7 (64-bit version)
Only STEP 7-Micro/WIN V4.x releas can accommodate a simultaneous connection with S7-200 PC For instance you cannot run communications in
STEP 7-Micro/WIN V3.x and S7-200 PC Access v1.x at the same time.
Note: If you experience unstable operation or unexplained program lockups,
plea examine the BIOS ttings of your computer and make sure
hyper-threading is disabled. To resolve other situations plea reboot your PC before running the ap
plication again.
3 Installation
1. Clo all applications including the MS-Office Toolbar.少儿英语教育
2. Inrt the STEP 7-Micro/WIN CD into the CD-Rom drive. The Setup program will
run automatically if you have not disabled the auto start option. You can manually
start the Setup program by double clicking the file "" located on the CD.
3. Follow the instructions displayed to complete the installation.
Note:To install STEP 7-Micro/WIN on a Windows XP or 7 operating system, you must log in with administrator rights.
Note:When you install STEP 7-Micro/WIN, the installer program asks you to specify
a target directory. It is recommended that you remove previous versions of
STEP 7-Micro/WIN prior to installing the new version. U "Add/Remove
Programs" from the Control Panel to uninstall the previous version.
4 Installing the upgrade licen
If a previous version of STEP 7-Micro/WIN is already installed on the computer, simply run the upgrade installation from the Upgrade CD. If you are installing to a new
computer with a new operating system, first you should install the full Individual Licen, and then run the upgrade installation from the Upgrade CD.
加盟店 英文Note:Installing STEP 7-Micro/WIN V4.0 SP9 upgrade licen on Windows 7 You must first install a full Individual Licen of an earlier version of STEP
7-Micro/WIN V4.0, and then run the SP9 upgrade installation from the Upgrade
CD. A Windows 7 computer can only run STEP 7-Micro/WIN V4.0 SP9. Notes on usage
5 What's new
To find out what's new in V4.0, run the STEP 7-Micro/WIN application and double-click on the "What's New" link at the top of the project tree.
6 Known problems and remedies
6.1 Problems
1. Help topics describing Microsoft Windows operation
The STEP 7-Micro/WIN V4.0 SP9 Help system contains graphics and text that describe operation with Microsoft Windows versions and communication devices that are no longer supported. Refer to the “Operating system and hardware
requirements” ction of this readme file for STEP 7-Micro/WIN V4.0 SP9 operating system and communication support information.
2. Installing CP Cards
You should always install STEP 7-Micro/WIN before inrting and installing any CP card. STEP 7-Micro/WIN contains I/O driver software that is ud by CP cards.
3. Managing Applications Access to the Serial Port
If you u the STEP 7-Micro/WIN Communications Setup or the PC/PG Interface under the PC Control Panel to t up the PC COM PORT parameters, certain
conditions will cau the COM Port lection field to be shown with an asterisk beside the COM Port number. This asterisk indicates that the ur's PC tup has already assigned another application to u the same COM Port. For example, if the Palm Pilot software is installed on the PC and you try to install STEP 7-Micro/WIN, this asterisk will appear becau Palm Pilot software typically loads each time the PC is booted up. You must unload (not uninstall) the other application to free up the COM Port so that
STEP 7-Micro/WIN can gain access to the port.
4. HP DeskJet Color Printers
If you are experiencing problems with an HP DeskJet color printer, or you are
experiencing problems with other printers, try downloading the newest available drivers from the printer manufacturer. Otherwi, you can change the printer driver to the Windows universal driver for your printer. For example (in the ca of the DeskJet), the universal driver is the 550c driver.
5. TD 200 Communication
A problem can occur during downloading or uploading a program using a CPU 215
or CPU 216 when an older TD 200 (pre-v1.2) is polling the CPU. The current
time-out error on the TD 200 is no longer appropriate for new CPU models. To work around this error, temporarily disconnect the TD 200 from the network, download or upload the program, and then reconnect the TD 200 to the network.
音频
6. TC-35 Cell Phone Modems
Certain Dell laptops ud with a Siemens TC-35 modem, will not properly
communicate. The problem is en with some Dell laptops that drive the transmit line high when the rial port is not in u. Becau of this, the Siemens TC-35 (and possibly other industry standard modems) rets causing initialization quencing problems followed by communication errors.
7. TC-35 Cell Phone Modem Remote Programming
Remote modem programming of a Siemens TC-35 modem us an &W
AT-command. Early firmware versions of this modem do not support this command.
Programming of this modem will fail, if this command is not supported.
8. Network Printers
appearancesIf a network printer is assigned as the default printer and the PC network connection is disconnected, there may be an error when starting STEP 7-Micro/WIN.
Reconnect the PC to the network or assign a local printer as the default printer and restart
STEP 7-Micro/WIN.
9. S7-200 Documentation CD
If you are experiencing problems with the "Programming Tips" ction of the S7-200 Documentation CD, you may need to install or update the Java Runtime
Environment. To download a free plug-in for this feature, go to and lect the "Free Downloads" link. Follow the instructions for installing the Java Runtime Environment, the re-start the S7-200 Documentation browr.
10. A box instruction that is connected directly to the left vertical rail does not always
execute. In the LAD network shown below, the DEC_B box will not execute every program scan. The DEC_B box in network 2 will execute only when the result of network 1 evaluates as TRUE (Q0.0=1) and will not execute if network 1 evaluates to FALSE (Q0.0).
11. A new Microsoft Windows 7 operating system installation cannot display the