DELL EDGE2950服务器LED显示代码说明

更新时间:2023-05-20 15:15:11 阅读: 评论:0

DellEdge 2950 LCD Messages2950前面版信息显示)
The following table provides detail on error messaged that may be displayed on the system LCD.
NOTE:
If the ur press and holds the ID button for approximately 5 conds, the LCD will enter the BIOS Progress Code state. This feature is very uful when troubleshooting a no POST or no video situations.
Cable and Board Prence - Message Code: x1Axx
Voltages - Message Code: x12xx
Processors - Message Code: x14xx
Power Supplies - Message Code: x16xx
Hard Drives - Message Code: x18xx
BIOS Progress Codes - Message Code: N/A
 
Temperature - Message Code: x11xx
Fans - Message Code: x13xx
System Memory - Message Code: x21xx
BIOS - Message Code: x17xx
Miscellaneous - Message Code: x19xx
BIOS Fatal Error Codes - Message Code: x20xx
Special Exceptions - Message Code: x10xx
Cable and Board Prence - Message Code: "x1Axx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1A10
PDBPwrCable
High
PDB power cable to the planar is missing or bad and system will not power on.
Failing device is reated/replaced/repaired.
Yes
Pre-Post
E1A11
PCIRsrConfig
High
PCI rirs are not configured correctly; some invalid configurations prevent system power on.
Failing device is reated/replaced/repaired.
Yes
Pre-Post
E1A12
PCIRsrMissing
High
One or all of the PCI rirs is missing. This prevents system power on.
Failing device is reated/replaced/repaired.
Yes
Pre-Post
E1A14
SAS Cable A
Low
SAS cable A is missing or bad.
Failing device is reated/replaced/repaired.
Yes
Any
E1A15
SAS Cable B
Low
SAS cable B is missing or bad.
Failing device is reated/replaced/repaired.
Yes
Any
E1A16
SAS Cable FB
Low
Flex bay SAS cable is missing or bad.
Failing device is reated/replaced/repaired.
Yes
Any
E1A17
PwrCable FB
Low
Flex bay power cable is missing or bad.
Failing device is reated/replaced/repaired.
Yes
Any
E1A18
PDBCtrl Cable
High
PDB control cable to the planar is missing or bad and system will not power on.
Failing device is reated/replaced/repaired.
Yes
Any
Temperature - Message Code: "x11xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1114
Temp Ambient
Med
Ambient temperature has a reached a point outside of the allowed range.
翻译在线
Temperature returns to allowable range.
Yes
Any
E1116
Temp Memory
High
Memory has exceeded allowable temperature and has been disabled to prevent damage to the components.
AC Cycle or SEL clear
Yes
Any
Voltages - Message Code: "x12xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1210
CMOSBatt
Low
CMOS battery is missing or the voltage is outside of the allowable range.
Failing device is reated/replaced/repaired.
Yes
Any
E1211
ROMBBatt
Low
PERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly becau of high temperatures), or the battery is bad.
Failing device is reated/replaced/repaired.
Yes
Any
W1228
ROMBBatt< 24 hr
Low
This is a predictive failure warning message telling the ur that the PERC5I RAID battery has less then 24 hours of charge left init. Wee provide this message as a warning message to the customer.
Battery charges to > 24 hours of sustained charge.
Yes
Any
E1214
1.5VPwrGd
High
1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1215
1.8VPwrGd
High
1.8 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1216
3.3VPwrGd
High
3.3V voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1217
5VPwrGd
High
5V voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1218
PCIRsr5VPwrGd
High
PCI Rir 5V voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1219
BackplanePwrGd
High
Backplane voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1221
Flex BayPwrGd
High
Flex Bay voltage regulator power good has failed.
AC Cycle or SEL clear
Yes
Any
E1222
VCACHE #PwrGd
High
VCACHE # voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1223
VRM #PwrGd
High
VRM # voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1225
ESB 1.5VPwrGd
High
ESB1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1226
PCIRsr1.5VPwrGd
High
PCI Rir 1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1227
LinearPwrGd
High
Linear voltage regulator(s) has failed. Reprents status of multiple voltage regulators ud in the video and LOM circuitry.
AC Cycle or SEL clear
Yes
Any
E1228
0.9VPwrGd
High
Memory VTT voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1229
CPU # VCORE
High
Processor # VCORE voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E122A
CPU VTTPwrGd
High
Processor VTT voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E122B
0.9 V Over Voltage
High
0.9 V regulator voltage has exceeded the allowable voltage range.
AC Cycle or SEL clear
Yes
Any
E122C
CPU Power Fault
High
A voltage regulator failure was detected when the processor regulator(s) was enabled.
AC Cycle or SEL clear
Yes
Any
Fans - Message Code: "x13xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1310
RPM Fan ##
Low
RPM of fan ## is outside of the intended operating range.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #A
Low
RPM of fan A in the # module is outside of the intended operating range.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #B
Low
Same as above except for fan B of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #C
Low
Same as above except for fan C of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #D
Low
Same as above except for fan D of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1313
Fan Redundancy
Low
The system is no longer fan redundant. Another fan failure would put the system at risk of over-heating.
Fan redundancy is regained, which requires all fans to be operating within the intended operating range.
Yes
Any
Processors - Message Code: "x14xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1410
CPU # IERR
High
Processor # has had an internal error (IERR), but this doesn’t always mean that CPU is the problem .There are a large variety of issues that cau an IERR.
AC Cycle or SEL clear
Yes
Any
E1414
CPU #Thermtrip
High
Processor # has encountered a Thermtrip(over-temperature) event.
street是什么意思AC Cycle or SEL clear
Yes
Any
E1418
CPU # Prence
High
Processor # is missing/bad and the system is in an unsupported configuration.
AC Cycle or SEL clear
Yes
Pre-POST
E141C
CPU Mismatch
High
Processors are not compatible as defined by Dell .System is in an unsupported configuration.
AC Cycle or SEL clear
Yes
Pre-POST
E141F
CPU Protocol
High
BIOS has reported a processor protocol error.
AC Cycle or SEL clear
Yes
POST, After POST
E1420
CPU Bus PERR
High
BIOS has reported a processor bus PERR (parity error).
AC Cycle or SEL clear
Yes
POST, After POST
E1421
CPU Init
High
BIOS has reported a processor initialization error.
AC Cycle or SEL clear
Yes
POST, After POST
E1422
CPU MachineChk
High
BIOS has reported a machine check error.
AC Cycle or SEL clear
Yes
POST, After POST
System Memory - Message Code: "x21xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E2110
MBECrdx DIMM ## & ##
High
One of the DIMMM's in the t implicated by "## & ##" has had a multi-bit error (MBE).If no memory rir is prent the Crdx string is left out of the message.x is the memory rir, A-Z.
AC Cycle or SEL clear
Yes
POST, After POST
E2111发型设计培训学校
SBE Log DisableCrdx DIMM ##
High
BIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEE's until the system is rebooted.## reprents DIMM implicated by BIOS .If no memory rir is prent the Crd x string is left out of the message.x is the memory rir, A-Z.
System ret
Yes
POST, After POST
E2112
MemSpareCrdx DIMM ##
High
BIOS has spared the memory becau it has determined the memory had too many errors.## reprents DIMM implicated by BIOS. If no memory rir is prent the Crdx string is left out of the message.暑期辅导班x is the memory rir, A-Z.
System ret
Yes
POST, After POST
E2113
Mem Mirror Crd x DIMM ## & ##
High
BIOS has disabled memory mirroring becau it has determined one half of the mirror has had too many errors. ## & ## reprents DIMM pair implicated by BIOS. If no memory rir is prent the Crdx string is left out of the message.x is the memory rir, A-Z.
System ret
Yes
POST, After POST
I2114
MemRaid
Low
BIOS Memory RAID Bank
Ur action, nsor return to normal
Yes
Any
I2115
MemAdded Card x
Low
Memory has been added while the system is running.
AC Cycle or SEL clear
Yes
Any
I2116
MemRemoved
Low
Memory has been removed while the system is running.
AC Cycle or SEL clear
Yes
Any
E2117
MemHot Plug
Low
Memory hot-plug operation has failed.
AC Cycle or SEL clear
Yes
Any
E2118
Fatal NBMemCRC
High
Northbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.
AC Cycle or SEL clear
Yes
POST, After POST
E2119
Fatal SBMemCRC
High
FBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMB'son the FBDIMM's) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.
AC Cycle or SEL clear
Yes
POST, After POST
Power Supplies - Message Code: "x16xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1610
PS # Missing
Low
Power supply # was removed or is missing from the system.
Failing device is reated/replaced/repaired.
Yes
Any
E1614
PS # Status
Low
Power supply # has failed.
Failing device is reated/replaced/repaired.
Yes
Any
E1618
PS # Predictive
Low
Power supply # has a failure that predicts a power down event in this supply (i.e. power supply fan failure or power supply over-temp).
Failing device is reated/replaced/repaired.
Yes
Any
E161C
PS # Input Lost
Low
Power supply # is attached to the system but has lost its AC/DC input.
Failing device is reated/replaced/repaired.
Yes
Any
E1620
PS #Input Range
Low
Power supply #'s AC/DC input is outside of the allowable range.
Failing device is reated/replaced/repaired.
Yes
Any
E1624
PS Redundancy
Low
The power supply subsystem is no longer redundant. If the last supply fails the system will go down.
Failing device is reated/replaced/repaired.
Yes
Any
E1625
PS AC Current
Low
The power supply input power is above the allowed amount for the power supply.
Failing device is reated/replaced/repaired.
Yes
Any
BIOS - Message Code: "x17xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1710
I/O ChannelChk
High
BIOS has reported an I/O channel check.
AC Cycle or SEL clear
Yes
POST, After POST
E1711
PCI PERR B## D## F##
High
turistas
BIOS has reported PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##.
AC Cycle or SEL clear
Yes
POST, After POST
E1711
PCI PERR Slot #
High
BIOS has reported PCI parity error on a component that resides in slot #.
Same as above.
Same as above.
Same as above.
E1712
PCI SERR B## D## F##
High
BIOS has reported a PCI system error on a component that resides in PCI configuration space at bus ##, device ##, function ##.
AC Cycle or SEL clear
Yes
POST, After POST
E1712
PCI SERR Slot #
High
BIOS has reported a PCI system error on a component that resides in slot #.
Same as above.
Same as above.
Same as above.
E1714
Unknown Err
Low
BIOS has determined there has been an error in the system but is unable to determine its origin.
AC Cycle or SEL clear
Yes
POST, After POST
E171F
PCIE Fatal Err B## D## F##
High
BIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##.
AC Cycle or SEL clear
Yes
POST, After POST
E171F
PCIE Fatal Slot #
High
BIOS has reported a PCIe fatal error on a component that resides in slot #.
Same as above.
Same as above.
Same as above.
Hard Drives - Message Code: "x18xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1810
HDD ## Fault
Low
Hard drive ## has had a fault as determined by the SAS subsystem.
AC Cycle or SEL clear
Yes
POST, After POST
E1811
HDD ##RbldAbrt
Low
Drive ## has had its rebuild aborted.
AC Cycle or SEL clear
Yes
POST, After POST
E1812
HDD ## Removed
Low
Drive ## has been removed from the system.
System ret or device is reated/replaced/repaired.
Yes
POST, After POST
Miscellaneous- Message Code: "x19xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
I1910
Intrusion
Low
The chassis lid has been removed.
Chassis lid is returned to the system.
Yes
Any
I1911
>3ERRsChkLog
N/A
Ur must check the system event log (SEL) for the rest of the errors on the system .Thee LCD is limited to three error, warning, and/or informational messages at a time bad on priority level.
Less than 3 events to display on the LCD.
No
Any
I1912
SEL Full
Med
System Event Log is full of events and becau of this is unable to log anymore. You must clear the log in order for the Server Management controller to log any more events.
AC Cycle or SEL clear
Yes
Any
E1913
CPU & Firmware Mismatch
Med
Current version of BMC firmware is incompatible with the Woodcrest processor.
AC Cycle or SEL clear
Yes
POST
BIOS Progress Codes - Message Code: N/A
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
N/A
POWER
N/A
0x01 -- System power-on.
N/A
No
Any
N/A
MCODE
N/A
0x02 -- CPU Microcode load.
N/A
No
Any
N/A
CINIT
N/A
0x03 -- Chipt Initialization.
N/A
No
Any
N/A
MEMC
N/A
0x04 -- Memory Configuration.
N/A
No
Any
N/A
SBIOS
N/A
0x05 -- BIOS shadow into memory.
N/A
No
Any
N/A
PINIT
struct
N/A
0x06 -- Multiprocessor Initialization.
N/A
No
Any
N/A
START
N/A
0x07 -- POST processing start.
N/A
No
Any
N/A
SMM
N/A
0x08 -- System management interrupt (SMI) initialization.
N/A
No
Any
N/A
PCIEN
N/A
0x09 -- PCI Bus Enumeration & Video initialization.
N/A
No
Any
N/A
VIDEO
N/A
0x40 -- Display sign-on.
N/A
No
Any
N/A
PCIC
N/A
0x41 -- PCI Configuration.
N/A
No
Any
N/A
OS
N/A
0x7F -- Give control to OS.
N/A
No
Any
N/A
E2010
N/A
0x80 -- No memory installed in the system.
N/A
No
Any
N/A
E2011
N/A
0x81 -- Memory detected but is not configurable .Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.
N/A
No
Any
N/A
E2012
N/A
0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.
N/A
No
Any
N/A
E2013
N/A
0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory.
N/A
No
Any
N/A
E2014
N/A
0x84 -- CMOS failure. CMOS'S RAM not working.
N/A
No
Any
N/A
E1215
N/A
0x05 -- DMA controller failure.
N/A
No
Any
N/A
E1116
N/A
0x80 -- Interrupt controller failure.
N/A
suggest的名词
No
Any
N/A
E1217
N/A
0x07 -- Timer refresh failure.
N/A
No
Any
N/A
E1218
N/A
0x28 -- Programmable interval timer error.
N/A
No
Any
N/A
E0119
N/A
0x29 -- Parity error.
N/A
No
Any
N/A
E122A
N/A
0x2a -- SIO failure.
N/A
No
Any
N/A
E122B
N/A
0x00b0 -- Keyboard controller failure.
N/A
No
Any
N/A
E141C
N/A
0x3c -- System management interrupt (SMI) initialization failure.
N/A
No
Any
N/A
E.11
N/A
0xC4 -- BIOS shutdown test failure.
N/A
No
Any
N/A
E.11
N/A
0xC4 -- BIOS POST memory test failure. Could be the result of bad memory.
N/A
No
Any
N/A
E141F
N/A
0xC4 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.
N/A
No
Any
N/A
E0000
N/A
0xC4 -- CPU configuration failure. Check screen for the actual error message.
N/A
No
Any
N/A
E1221
N/A
0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the ur guide.
N/A
No
Any
N/A
E1222
N/A
22x -- General failure after video. Check screen for the actual error message.
N/A
No
Any
BIOS Fatal Error Codes - Message Code: "x20xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E2010
No Memory
High
0x80 -- No memory installed in the system.
System ret
Yes
POST
E2011
MemConfigErr
High
0x81 -- Memory detected but is not configurable. Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.
System ret
Yes
POST
E2012
Unusable Memory
High
0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.
System ret
Yes
POST
E2013
Shadow BIOS Fail
High
0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory.
System ret
Yes
POST
E2014
CMOS Fail
High
0x84 -- CMOS failure. CMOS'S RAM not working.
System ret
Yes
POST
E2015
DMA Controller
High
0x85 -- DMA controller failure.
System ret
Yes
POST
E2016
IntController
High
0x86 -- Interrupt controller failure.
System ret
Yes
POST
E2017
Timer Fail
High
0x87 -- Timer refresh failure.
System ret
Yes
POST
E2018
ProgTimer
High
0x88 -- Programmable interval timer error.
System ret
Yes
POST
E2019
Parity Error
High
0x89 -- Parity error.
System ret
Yes
POST
E201A
SIO Err
High
0x8A -- SIO failure.
System ret
Yes
POST
E201B
KybdController
High
0x8B -- Keyboard controller failure.
System ret
Yes
POST
E201C
SMI Init
High
0x8C -- System management interrupt (SMI) initialization failure.
System ret
Yes
POST
E201D
Shutdown Test
High
0xC0 -- BIOS shutdown test failure.
System ret
Yes
POST
E201E
POSTMemTest
High
0xC1 -- BIOS POST memory test failure. Could be the result of bad memory.
System ret
Yes
POST
E201F
DRACConfig
High
0xC2 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.
System ret
Yes
POST
E2020
CPUConfig
High
0xC3 -- CPU configuration failure. Check screen for the actual error message.
System ret
Yes
POST
E2021
Memory Population
High
0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the ur guide.
System ret
Yes
POST
E2022
POST Fail
High
0xFE -- General failure after video. Check screen for the actual error message.
System ret
Yes
POST
Special Exceptions - Message Code: "x10xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1000
Failsafe, Call Support
Special
Check System Event Log for critical failure details.
AC Cycle or SEL clear
Yes
Any
 
 
LCD 状态信息
系统的控制面板 LCD 可以提供状态信息,以表示系统何时运行正常,何时需要注意。
LCD 呈蓝色亮起表示系统运行正常,呈琥珀色亮起表示出现错误。LCD 滚动显示信息,包括状态代码及其后跟的描述性文本。表 1-6 列出了可能出现的 LCD 状态信息和导致生成每则信息的可能原因。LCD 信息引用系统事件日志 (SEL) 中记录的事件。有关 SEL 和配置系统管理设置的信息,请参阅系统管理软件说明文件。
警告:只有经过培训的维修技术人员才能卸下系统主机盖并拆装系统的任何内部组件。有关安全预防措施、拆装计算机内部组件和防止静电损害的完整信息,请参阅《产品信息指南》。
注:如果系统无法引导,按下系统 ID”按钮至少五秒钟,直至 LCD 上显示错误代码。记录该代码,然后请参阅获得帮助
1-6. LCD 状态信息
modal
代码
文本
原因
更正措施
N/A
SYSTEM NAME
62 个字符组成的字符串,可由用户在系统设置程序中定义。
在以下情况下显示 SYSTEM NAME
打开系统电源。
关闭系统电源并显示活动 POST 错误。
此信息仅用于提供信息。
可以在系统设置程序中更改系统 ID 和系统名称。请参阅使用系统设置程序
E1000
FAILSAFE, Call Support
 
请参阅获得帮助
E1114
Temp Ambient
系统周围环境温度超出允许范围。
请参阅排除系统冷却故障
E1116
Temp Memory
内存已超过允许温度,系统已将其禁用以防止损坏组件。
请参阅排除系统冷却故障
E12nn
xx PwrGd
指定的稳压器出现故障。
请参阅获得帮助
E1210
CMOS Batt
缺少 CMOS 电池,或电压超出允许范围。
请参阅排除系统电池故障
E1211
ROMB Batt
RAID 电池丢失、损坏或因温度问题而无法再充电。
重置 RAID 电池连接器。请参阅 RAID 电池排除系统冷却故障
E1229
CPU # VCORE
处理器 # VCORE 稳压器出现故障。
请参阅获得帮助
E1310
RPM Fan ##
指定的冷却风扇的 RPM 超出允许的运行范围。
请参阅排除系统冷却故障
E1313
Fan Redundancy
系统中的风扇不再有冗余。如果风扇再出现故障,系统将有过热危险。
检查控制面板 LCD 以获取其它滚动信息。请参阅排除系统冷却故障
E1410
CPU # IERR
指定的微处理器报告内部错误。
请参阅系统的信息更新技术表(位于 ),以获取最新的系统信息。如果问题仍然存在,请参阅获得帮助
E1414
CPU # Thermtrip
指定的微处理器超出了允许的温度范围并已停止运行。
请参阅排除系统冷却故障。如果问题仍然存在,请确保微处理器散热器安装正确。请参阅排除微处理器故障
注:LCD 将继续显示此信息,直到断开系统的电源线连接并将其重新连接至交流电源,或使用 Server Assistant BMC 管理公用程序清除 SEL 为止。有关这些公用程序的信息,请参阅Dell OpenManage 底板管理控制器用户指南》
E1418
CPU # Prence
指定的处理器丢失或损坏,系统的配置不受支持。
请参阅排除微处理器故障
E141C
CPU Mismatch
处理器的配置不受 Dell 支持。
确保您的处理器与系统的《使用入门指南》概述的微处理器技术规格中介绍的型号匹配并相符。
E141F
CPU Protocol
系统 BIOS 已报告处理器协议错误。
请参阅获得帮助
E1420
CPU Bus PERR
系统 BIOS 已报告处理器总线奇偶校验错误。
请参阅获得帮助
E1421
CPU Init
系统 BIOS 已报告处理器初始化错误。
请参阅获得帮助
E1422
CPU Machine Chk
系统 BIOS 已报告机器检查错误。
请参阅获得帮助
E1610
PS # Missing
指定的电源设备中没有电;指定的电源设备安装错误或出现故障。
请参阅排除电源设备故障
E1614
PS # Status
指定的电源设备中没有电;指定的电源设备安装错误或出现故障。
请参阅排除电源设备故障
E1618
PS # Predictive
电源设备电压超出允许范围;指定的电源设备安装错误或出现故障。
请参阅排除电源设备故障
E161C
PS # Input Lost
指定的电源设备的电源不可用,或超出了允许范围。
检查指定电源设备的交流电源。如果问题仍然存在,请参阅排除电源设备故障
E1620
PS # Input Range
指定的电源设备的电源不可用,或超出了允许范围。
检查指定电源设备的交流电源。如果问题仍然存在,请参阅排除电源设备故障
E1624
PS Redundancy
电源设备子系统不再有冗余。如果仅有的电源设备出现故障,系统将关闭。
请参阅排除电源设备故障
E1710
I/O Channel Chk
系统 BIOS 已报告 I/O 通道检查。
请参阅获得帮助
E1711
PCI PERR B## D## F##
PCI PERR Slot #
系统 BIOS 已报告组件的 PCI 奇偶校验错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##
系统 BIOS 已报告组件的 PCI 奇偶校验错误,该组件位于指定的 PCI 插槽。
卸下并重置 PCI 扩充卡。如果问题仍然存在,请参阅排除扩充卡故障
重新安装扩充卡固定框架。请参阅扩充卡固定框架
如果问题仍然存在,则表示提升卡或系统板出现故障。请参阅获得帮助
E1712
PCI SERR B## D## F##
PCI SERR Slot #
系统 BIOS 已报告组件的 PCI 系统错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##
系统 BIOS 已报告组件的 PCI 系统错误,该组件位于指定的插槽。
卸下并重置 PCI 扩充卡。如果问题仍然存在,请参阅排除扩充卡故障
重新安装扩充卡固定框架。请参阅扩充卡固定框架
如果问题仍然存在,则表示提升卡或系统板出现故障。请参阅获得帮助
E1714
Unknown Err
系统 BIOS 已确定系统中存在错误,但无法确定错误来源。
请参阅获得帮助
E171F
PCIE Fatal Err B## D## F##
PCIE Fatal Err Slot #
系统 BIOS 已报告组件的 PCIe 致命错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##
系统 BIOS 已报告组件的 PCIe 致命错误,该组件位于指定的插槽。
卸下并重置 PCI 扩充卡。如果问题仍然存在,请参阅排除扩充卡故障
重新安装扩充卡固定框架。请参阅扩充卡固定框架
如果问题仍然存在,则表示提升卡或系统板出现故障。请参阅获得帮助
E1810
HDD ## Fault
SAS 子系统已确定硬盘驱动器 ## 出现故障。
请参阅排除硬盘驱动器故障
E1811
HDD ## Rbld Abrt
指定的硬盘驱动器已放弃重建。
请参阅排除硬盘驱动器故障。如果问题仍然存在,请参阅 RAID 说明文件。
E1812
HDD ## Removed
指定的硬盘驱动器已从系统中卸下。
仅提供信息。
E1913
CPU & Firmware Mismatch
BMC 固件不支持 CPU
更新至最新的 BMC 固件。有关设置和使用 BMC 的详细信息,请参阅BMC 用户指南》
E1A11
PCI Rsr Config
PCI 提升板未正确配置;一些无效配置可能会阻碍系统通电。
请参阅扩充卡提升板
E1A12
PCI Rsr Missing
一个或所有 PCI 提升板丢失,阻碍系统通电。
仅提供信息。
E1A14
SAS Cable A
SAS 电缆 A 丢失或损坏。
重置电缆。如果问题仍然存在,请更换电缆。请参阅 SAS 控制器子卡
E1A15
SAS Cable B
SAS 电缆 B 丢失或损坏。
置电缆。如果问题仍然存在,请更换电缆。请参阅 SAS 控制器子卡
E2010
No Memory
系统中没有安装内存。
安装内存。请参阅安装内存模块
E2011
Mem Config Err
检测到内存,但是内存不可配置。配置内存期间检测到错误。
请参阅排除系统内存故障
E2012
Unusable Memory
已配置内存,但内存不可用。内存子系统出现故障。
请参阅排除系统内存故障
E2013
Shadow BIOS Fail
系统 BIOS 无法将其快擦写映像复制到内存中。
请参阅排除系统内存故障
E2014
CMOS Fail
CMOS 出现故障。CMOS RAM 未正常工作。
请参阅获得帮助
E2015
DMA Controller
DMA 控制器出现故障。
请参阅获得帮助
E2016
Int Controller
中断控制器出现故障。
请参阅获得帮助
E2017
Timer Fail
计时器刷新故障。
请参阅获得帮助
lantis
E2018
Prog Timer
可编程间隔计时器错误。
请参阅获得帮助
E2019
Parity Error
奇偶校验错误。
请参阅获得帮助
E201A
SIO Err
SIO 出现故障。
请参阅获得帮助
E201B
Kybd Controller
键盘控制器出现故障。
请参阅获得帮助
E201C
SMI Init
系统管理中断 (SMI) 初始化失败。
请参阅获得帮助
E201D
Shutdown Test
BIOS 关闭系统检测失败。
请参阅获得帮助
E201E
POST Mem Test
BIOS POST 内存检测失败。
请参阅排除系统内存故障。如果问题仍然存在,请参阅获得帮助
E201F
DRAC Config
Dell 远程访问控制器 (DRAC) 配置失败。
请查看屏幕上的具体错误信息。
确保 DRAC 电缆和连接器已正确就位。如果问题仍然存在,请参阅 DRAC 说明文件。
E2020
CPU Config
CPU 配置失败。
请查看屏幕上的具体错误信息。
E2021
Memory Population
内存配置不正确。内存安装顺序不正确。
请查看屏幕上的具体错误信息。请参阅排除系统内存故障
E2022
POST Fail
视频后出现一般故障。
请查看屏幕上的具体错误信息。
E2110
MBE Crd # DIMM ## & ##
“## & ##”指示的 DIMM 组中的一个 DIMM 发生内存多位错误 (MBE)。如果没有内存卡,则“Crd #”字符串将留在信息外。
请参阅排除系统内存故障
E2111
SBE Log Disable Crd # DIMM ##
系统 BIOS 已禁用内存单位错误 (SBE) 记录,在重新引导系统之前,不会再记录更多的 SBE“##”表示 BIOS 指示的 DIMM。如果没有内存提升卡,则“Crd #”字符串将留在信息外。
请参阅排除系统内存故障
E2112
Mem Spare Crd # DIMM ##
系统 BIOS 确定内存中有太多错误,因此已将内存释放。“## & ##”表示 BIOS 指示的 DIMM 对。如果没有内存卡,则“Crd #”字符串将留在信息外。
请参阅排除系统内存故障
E2113
Mem Mirror Crd # DIMM ## & ##
系统 BIOS 确定一半镜像中有太多错误,因此已将内存镜像禁用。“## & ##”表示 BIOS 指示的 DIMM 对。如果没有内存卡,则“Crd #”字符串将留在信息外。
请参阅排除系统内存故障
E2118
Fatal NB Mem CRC
北侧的全缓冲 DIMM (FBD) 内存子系统链接中的一个连接失败。
请参阅排除系统内存故障
E2119
Fatal SB Mem CRC
南侧的 FBD 内存子系统链接中的一个连接失败。
请参阅排除系统内存故障
I1910
Intrusion
主机盖被卸下。
仅提供信息。
I1911
>3 ERRs Chk Log
LCD 溢出信息。
LCD 上最多只能按顺序显示三条错误信息。第四条信息显示为标准的溢出信息。
查看 SEL 以获取事件详细信息。
I1912
SEL Full
系统事件日志中的事件已满,无法再记录更多事件。
通过删除事件条目清除日志。
W1228
ROMB Batt < 24hr
预先警告 RAID 电池只剩下不足 24 小时的电量。
更换 RAID 电池。请参阅 RAID 电池
注:有关本表中使用的缩写词和缩略词的全称,请参阅词汇表
解决 LCD 状态信息描述的问题
LCD 中的代码和文本通常可以精确指明故障情况,因此更正起来十分方便。例如,如果显示代码 E1418  CPU_1_Prence,您即可知道插槽 1 中没有安装微处理器。
相比之下,如果发生多个相关错误,您也许能够确定问题所在。例如,如果收到一系列信息,指示多种电压故障,您可能确定问题来自电源设备故障。
删除 LCD 状态信息
对于与传感器有关的故障,例如温度、电压、风扇等,当传感器恢复至正常状态时,LCD 信息将被自动删除。例如,如果某组件的温度超出范围,LCD 将显示该故障,温度恢复至允许范围后,该信息将从 LCD 中删除。对于其它故障,必须采取措施将信息从显示屏中删除:
清除 SEL - 您可以远程执行该任务,但是系统的事件历史记录将丢失。
关闭电源再打开 - 关闭系统电源并断开其与电源插座的连接;等待大约十秒钟,重新连接电源电缆,然后重新启动系统。
任一措施都将删除故障信息,并使状态指示灯和 LCD 颜色恢复至正常状态。在以下情况下,将重新显示信息:
传感器恢复至正常状态后再次发生故障,从而生成了新的 SEL 条目。
系统重启动并检测到新的错误事件。
记录了与同一显示条目对应的另外一种故障。
发件人: Lin, Yongliang
发送时间: 20081222 9:47
收件人: ''
主题: PE2950 BIOS UPDATE
Dear zhang:
 
/support/downloads/download.aspx?c=cn&l=zh&s=gen&relea
id=R202414&SystemID=PWE_2950&rvicetag=DNY5D2X&os=WNET&osl=CS&deviceid=11598&devlib=0&typecnt=0&vercnt=11&catid=-1&impid=-1&formatcnt=6&libid=1&fileid=281429
 
BIOS FIRMWARE UPDATE
 
Yongliang_lin
林永亮
China Commercial Technical Support
zpn中文官方技术支持网站:
中文官方技术支持论坛:/
Dell硬件技术支持聊天室:/chat
How am I doing? 欢迎您对我的服务做出评价 (John_)
 

本文发布于:2023-05-20 15:15:11,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/90/115942.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:系统   故障   信息
相关文章
留言与评论(共有 0 条评论)
   
验证码:
Copyright ©2019-2022 Comsenz Inc.Powered by © 专利检索| 网站地图