NOTE: If the ur press and holds the ID button for approximately 5 conds, the LCD will enter the BIOS Progress Code state. This feature is very uful when troubleshooting a no POST or no video situations. | |
∙ Cable and Board Prence - Message Code: x1Axx ∙ Voltages - Message Code: x12xx ∙ Processors - Message Code: x14xx ∙ Power Supplies - Message Code: x16xx ∙ Hard Drives - Message Code: x18xx ∙ BIOS Progress Codes - Message Code: N/A | ∙ Temperature - Message Code: x11xx ∙ Fans - Message Code: x13xx ∙ System Memory - Message Code: x21xx ∙ BIOS - Message Code: x17xx ∙ Miscellaneous - Message Code: x19xx ∙ BIOS Fatal Error Codes - Message Code: x20xx ∙ Special Exceptions - Message Code: x10xx | |
Cable and Board Prence - Message Code: "x1Axx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E1A10 | PDBPwrCable | High | PDB power cable to the planar is missing or bad and system will not power on. | Failing device is reated/replaced/repaired. | Yes | Pre-Post | |
E1A11 | PCIRsrConfig | High | PCI rirs are not configured correctly; some invalid configurations prevent system power on. | Failing device is reated/replaced/repaired. | Yes | Pre-Post | |
E1A12 | PCIRsrMissing | High | One or all of the PCI rirs is missing. This prevents system power on. | Failing device is reated/replaced/repaired. | Yes | Pre-Post | |
E1A14 | SAS Cable A | Low | SAS cable A is missing or bad. | Failing device is reated/replaced/repaired. | Yes | Any | |
E1A15 | SAS Cable B | Low | SAS cable B is missing or bad. | Failing device is reated/replaced/repaired. | Yes | Any | |
E1A16 | SAS Cable FB | Low | Flex bay SAS cable is missing or bad. | Failing device is reated/replaced/repaired. | Yes | Any | |
E1A17 | PwrCable FB | Low | Flex bay power cable is missing or bad. | Failing device is reated/replaced/repaired. | Yes | Any | |
E1A18 | PDBCtrl Cable | High | PDB control cable to the planar is missing or bad and system will not power on. | Failing device is reated/replaced/repaired. | Yes | Any | |
Temperature - Message Code: "x11xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E1114 | Temp Ambient | Med | Ambient temperature has a reached a point outside of the allowed range. 翻译在线 | Temperature returns to allowable range. | Yes | Any | |
E1116 | Temp Memory | High | Memory has exceeded allowable temperature and has been disabled to prevent damage to the components. | AC Cycle or SEL clear | Yes | Any | |
Voltages - Message Code: "x12xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E1210 | CMOSBatt | Low | CMOS battery is missing or the voltage is outside of the allowable range. | Failing device is reated/replaced/repaired. | Yes | Any | |
E1211 | ROMBBatt | Low | PERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly becau of high temperatures), or the battery is bad. | Failing device is reated/replaced/repaired. | Yes | Any | |
W1228 | ROMBBatt< 24 hr | Low | This is a predictive failure warning message telling the ur that the PERC5I RAID battery has less then 24 hours of charge left init. Wee provide this message as a warning message to the customer. | Battery charges to > 24 hours of sustained charge. | Yes | Any | |
E1214 | 1.5VPwrGd | High | 1.5 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1215 | 1.8VPwrGd | High | 1.8 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1216 | 3.3VPwrGd | High | 3.3V voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1217 | 5VPwrGd | High | 5V voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1218 | PCIRsr5VPwrGd | High | PCI Rir 5V voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1219 | BackplanePwrGd | High | Backplane voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1221 | Flex BayPwrGd | High | Flex Bay voltage regulator power good has failed. | AC Cycle or SEL clear | Yes | Any | |
E1222 | VCACHE #PwrGd | High | VCACHE # voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1223 | VRM #PwrGd | High | VRM # voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1225 | ESB 1.5VPwrGd | High | ESB1.5 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1226 | PCIRsr1.5VPwrGd | High | PCI Rir 1.5 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1227 | LinearPwrGd | High | Linear voltage regulator(s) has failed. Reprents status of multiple voltage regulators ud in the video and LOM circuitry. | AC Cycle or SEL clear | Yes | Any | |
E1228 | 0.9VPwrGd | High | Memory VTT voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E1229 | CPU # VCORE | High | Processor # VCORE voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E122A | CPU VTTPwrGd | High | Processor VTT voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any | |
E122B | 0.9 V Over Voltage | High | 0.9 V regulator voltage has exceeded the allowable voltage range. | AC Cycle or SEL clear | Yes | Any | |
E122C | CPU Power Fault | High | A voltage regulator failure was detected when the processor regulator(s) was enabled. | AC Cycle or SEL clear | Yes | Any | |
Fans - Message Code: "x13xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E1310 | RPM Fan ## | Low | RPM of fan ## is outside of the intended operating range. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any | |
E1311 | RPM Fan Mod #A | Low | RPM of fan A in the # module is outside of the intended operating range. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any | |
E1311 | RPM Fan Mod #B | Low | Same as above except for fan B of module #. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any | |
E1311 | RPM Fan Mod #C | Low | Same as above except for fan C of module #. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any | |
E1311 | RPM Fan Mod #D | Low | Same as above except for fan D of module #. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any | |
E1313 | Fan Redundancy | Low | The system is no longer fan redundant. Another fan failure would put the system at risk of over-heating. | Fan redundancy is regained, which requires all fans to be operating within the intended operating range. | Yes | Any | |
Processors - Message Code: "x14xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E1410 | CPU # IERR | High | Processor # has had an internal error (IERR), but this doesn’t always mean that CPU is the problem .There are a large variety of issues that cau an IERR. | AC Cycle or SEL clear | Yes | Any | |
E1414 | CPU #Thermtrip | High | Processor # has encountered a Thermtrip(over-temperature) event. | street是什么意思AC Cycle or SEL clear | Yes | Any | |
E1418 | CPU # Prence | High | Processor # is missing/bad and the system is in an unsupported configuration. | AC Cycle or SEL clear | Yes | Pre-POST | |
E141C | CPU Mismatch | High | Processors are not compatible as defined by Dell .System is in an unsupported configuration. | AC Cycle or SEL clear | Yes | Pre-POST | |
E141F | CPU Protocol | High | BIOS has reported a processor protocol error. | AC Cycle or SEL clear | Yes | POST, After POST | |
E1420 | CPU Bus PERR | High | BIOS has reported a processor bus PERR (parity error). | AC Cycle or SEL clear | Yes | POST, After POST | |
E1421 | CPU Init | High | BIOS has reported a processor initialization error. | AC Cycle or SEL clear | Yes | POST, After POST | |
E1422 | CPU MachineChk | High | BIOS has reported a machine check error. | AC Cycle or SEL clear | Yes | POST, After POST | |
System Memory - Message Code: "x21xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E2110 | MBECrdx DIMM ## & ## | High | One of the DIMMM's in the t implicated by "## & ##" has had a multi-bit error (MBE).If no memory rir is prent the “Crdx” string is left out of the message.“x” is the memory rir, A-Z. | AC Cycle or SEL clear | Yes | POST, After POST | |
E2111发型设计培训学校 | SBE Log DisableCrdx DIMM ## | High | BIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEE's until the system is rebooted.## reprents DIMM implicated by BIOS .If no memory rir is prent the “Crd x” string is left out of the message.“x” is the memory rir, A-Z. | System ret | Yes | POST, After POST | |
E2112 | MemSpareCrdx DIMM ## | High | BIOS has spared the memory becau it has determined the memory had too many errors.## reprents DIMM implicated by BIOS. If no memory rir is prent the “Crdx” string is left out of the message.暑期辅导班“x” is the memory rir, A-Z. | System ret | Yes | POST, After POST | |
E2113 | Mem Mirror Crd x DIMM ## & ## | High | BIOS has disabled memory mirroring becau it has determined one half of the mirror has had too many errors. ## & ## reprents DIMM pair implicated by BIOS. If no memory rir is prent the “Crdx” string is left out of the message.“x” is the memory rir, A-Z. | System ret | Yes | POST, After POST | |
I2114 | MemRaid | Low | BIOS Memory RAID Bank | Ur action, nsor return to normal | Yes | Any | |
I2115 | MemAdded Card x | Low | Memory has been added while the system is running. | AC Cycle or SEL clear | Yes | Any | |
I2116 | MemRemoved | Low | Memory has been removed while the system is running. | AC Cycle or SEL clear | Yes | Any | |
E2117 | MemHot Plug | Low | Memory hot-plug operation has failed. | AC Cycle or SEL clear | Yes | Any | |
E2118 | Fatal NBMemCRC | High | Northbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row. | AC Cycle or SEL clear | Yes | POST, After POST | |
E2119 | Fatal SBMemCRC | High | FBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMB'son the FBDIMM's) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row. | AC Cycle or SEL clear | Yes | POST, After POST | |
Power Supplies - Message Code: "x16xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E1610 | PS # Missing | Low | Power supply # was removed or is missing from the system. | Failing device is reated/replaced/repaired. | Yes | Any | |
E1614 | PS # Status | Low | Power supply # has failed. | Failing device is reated/replaced/repaired. | Yes | Any | |
E1618 | PS # Predictive | Low | Power supply # has a failure that predicts a power down event in this supply (i.e. power supply fan failure or power supply over-temp). | Failing device is reated/replaced/repaired. | Yes | Any | |
E161C | PS # Input Lost | Low | Power supply # is attached to the system but has lost its AC/DC input. | Failing device is reated/replaced/repaired. | Yes | Any | |
E1620 | PS #Input Range | Low | Power supply #'s AC/DC input is outside of the allowable range. | Failing device is reated/replaced/repaired. | Yes | Any | |
E1624 | PS Redundancy | Low | The power supply subsystem is no longer redundant. If the last supply fails the system will go down. | Failing device is reated/replaced/repaired. | Yes | Any | |
E1625 | PS AC Current | Low | The power supply input power is above the allowed amount for the power supply. | Failing device is reated/replaced/repaired. | Yes | Any | |
BIOS - Message Code: "x17xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E1710 | I/O ChannelChk | High | BIOS has reported an I/O channel check. | AC Cycle or SEL clear | Yes | POST, After POST | |
E1711 | PCI PERR B## D## F## | High | turistas BIOS has reported PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##. | AC Cycle or SEL clear | Yes | POST, After POST | |
E1711 | PCI PERR Slot # | High | BIOS has reported PCI parity error on a component that resides in slot #. | Same as above. | Same as above. | Same as above. | |
E1712 | PCI SERR B## D## F## | High | BIOS has reported a PCI system error on a component that resides in PCI configuration space at bus ##, device ##, function ##. | AC Cycle or SEL clear | Yes | POST, After POST | |
E1712 | PCI SERR Slot # | High | BIOS has reported a PCI system error on a component that resides in slot #. | Same as above. | Same as above. | Same as above. | |
E1714 | Unknown Err | Low | BIOS has determined there has been an error in the system but is unable to determine its origin. | AC Cycle or SEL clear | Yes | POST, After POST | |
E171F | PCIE Fatal Err B## D## F## | High | BIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##. | AC Cycle or SEL clear | Yes | POST, After POST | |
E171F | PCIE Fatal Slot # | High | BIOS has reported a PCIe fatal error on a component that resides in slot #. | Same as above. | Same as above. | Same as above. | |
Hard Drives - Message Code: "x18xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E1810 | HDD ## Fault | Low | Hard drive ## has had a fault as determined by the SAS subsystem. | AC Cycle or SEL clear | Yes | POST, After POST | |
E1811 | HDD ##RbldAbrt | Low | Drive ## has had its rebuild aborted. | AC Cycle or SEL clear | Yes | POST, After POST | |
E1812 | HDD ## Removed | Low | Drive ## has been removed from the system. | System ret or device is reated/replaced/repaired. | Yes | POST, After POST | |
Miscellaneous- Message Code: "x19xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
I1910 | Intrusion | Low | The chassis lid has been removed. | Chassis lid is returned to the system. | Yes | Any | |
I1911 | >3ERRsChkLog | N/A | Ur must check the system event log (SEL) for the rest of the errors on the system .Thee LCD is limited to three error, warning, and/or informational messages at a time bad on priority level. | Less than 3 events to display on the LCD. | No | Any | |
I1912 | SEL Full | Med | System Event Log is full of events and becau of this is unable to log anymore. You must clear the log in order for the Server Management controller to log any more events. | AC Cycle or SEL clear | Yes | Any | |
E1913 | CPU & Firmware Mismatch | Med | Current version of BMC firmware is incompatible with the Woodcrest processor. | AC Cycle or SEL clear | Yes | POST | |
BIOS Progress Codes - Message Code: N/A | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
N/A | POWER | N/A | 0x01 -- System power-on. | N/A | No | Any | |
N/A | MCODE | N/A | 0x02 -- CPU Microcode load. | N/A | No | Any | |
N/A | CINIT | N/A | 0x03 -- Chipt Initialization. | N/A | No | Any | |
N/A | MEMC | N/A | 0x04 -- Memory Configuration. | N/A | No | Any | |
N/A | SBIOS | N/A | 0x05 -- BIOS shadow into memory. | N/A | No | Any | |
N/A | PINIT struct | N/A | 0x06 -- Multiprocessor Initialization. | N/A | No | Any | |
N/A | START | N/A | 0x07 -- POST processing start. | N/A | No | Any | |
N/A | SMM | N/A | 0x08 -- System management interrupt (SMI) initialization. | N/A | No | Any | |
N/A | PCIEN | N/A | 0x09 -- PCI Bus Enumeration & Video initialization. | N/A | No | Any | |
N/A | VIDEO | N/A | 0x40 -- Display sign-on. | N/A | No | Any | |
N/A | PCIC | N/A | 0x41 -- PCI Configuration. | N/A | No | Any | |
N/A | OS | N/A | 0x7F -- Give control to OS. | N/A | No | Any | |
N/A | E2010 | N/A | 0x80 -- No memory installed in the system. | N/A | No | Any | |
N/A | E2011 | N/A | 0x81 -- Memory detected but is not configurable .Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket. | N/A | No | Any | |
N/A | E2012 | N/A | 0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory. | N/A | No | Any | |
N/A | E2013 | N/A | 0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory. | N/A | No | Any | |
N/A | E2014 | N/A | 0x84 -- CMOS failure. CMOS'S RAM not working. | N/A | No | Any | |
N/A | E1215 | N/A | 0x05 -- DMA controller failure. | N/A | No | Any | |
N/A | E1116 | N/A | 0x80 -- Interrupt controller failure. | N/A suggest的名词 | No | Any | |
N/A | E1217 | N/A | 0x07 -- Timer refresh failure. | N/A | No | Any | |
N/A | E1218 | N/A | 0x28 -- Programmable interval timer error. | N/A | No | Any | |
N/A | E0119 | N/A | 0x29 -- Parity error. | N/A | No | Any | |
N/A | E122A | N/A | 0x2a -- SIO failure. | N/A | No | Any | |
N/A | E122B | N/A | 0x00b0 -- Keyboard controller failure. | N/A | No | Any | |
N/A | E141C | N/A | 0x3c -- System management interrupt (SMI) initialization failure. | N/A | No | Any | |
N/A | E.11 | N/A | 0xC4 -- BIOS shutdown test failure. | N/A | No | Any | |
N/A | E.11 | N/A | 0xC4 -- BIOS POST memory test failure. Could be the result of bad memory. | N/A | No | Any | |
N/A | E141F | N/A | 0xC4 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message. | N/A | No | Any | |
N/A | E0000 | N/A | 0xC4 -- CPU configuration failure. Check screen for the actual error message. | N/A | No | Any | |
N/A | E1221 | N/A | 0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the ur guide. | N/A | No | Any | |
N/A | E1222 | N/A | 22x -- General failure after video. Check screen for the actual error message. | N/A | No | Any | |
BIOS Fatal Error Codes - Message Code: "x20xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E2010 | No Memory | High | 0x80 -- No memory installed in the system. | System ret | Yes | POST | |
E2011 | MemConfigErr | High | 0x81 -- Memory detected but is not configurable. Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket. | System ret | Yes | POST | |
E2012 | Unusable Memory | High | 0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory. | System ret | Yes | POST | |
E2013 | Shadow BIOS Fail | High | 0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory. | System ret | Yes | POST | |
E2014 | CMOS Fail | High | 0x84 -- CMOS failure. CMOS'S RAM not working. | System ret | Yes | POST | |
E2015 | DMA Controller | High | 0x85 -- DMA controller failure. | System ret | Yes | POST | |
E2016 | IntController | High | 0x86 -- Interrupt controller failure. | System ret | Yes | POST | |
E2017 | Timer Fail | High | 0x87 -- Timer refresh failure. | System ret | Yes | POST | |
E2018 | ProgTimer | High | 0x88 -- Programmable interval timer error. | System ret | Yes | POST | |
E2019 | Parity Error | High | 0x89 -- Parity error. | System ret | Yes | POST | |
E201A | SIO Err | High | 0x8A -- SIO failure. | System ret | Yes | POST | |
E201B | KybdController | High | 0x8B -- Keyboard controller failure. | System ret | Yes | POST | |
E201C | SMI Init | High | 0x8C -- System management interrupt (SMI) initialization failure. | System ret | Yes | POST | |
E201D | Shutdown Test | High | 0xC0 -- BIOS shutdown test failure. | System ret | Yes | POST | |
E201E | POSTMemTest | High | 0xC1 -- BIOS POST memory test failure. Could be the result of bad memory. | System ret | Yes | POST | |
E201F | DRACConfig | High | 0xC2 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message. | System ret | Yes | POST | |
E2020 | CPUConfig | High | 0xC3 -- CPU configuration failure. Check screen for the actual error message. | System ret | Yes | POST | |
E2021 | Memory Population | High | 0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the ur guide. | System ret | Yes | POST | |
E2022 | POST Fail | High | 0xFE -- General failure after video. Check screen for the actual error message. | System ret | Yes | POST | |
Special Exceptions - Message Code: "x10xx" | |||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? | |
E1000 | Failsafe, Call Support | Special | Check System Event Log for critical failure details. | AC Cycle or SEL clear | Yes | Any | |
警告:只有经过培训的维修技术人员才能卸下系统主机盖并拆装系统的任何内部组件。有关安全预防措施、拆装计算机内部组件和防止静电损害的完整信息,请参阅《产品信息指南》。 | |
注:如果系统无法引导,按下“系统 ID”按钮至少五秒钟,直至 LCD 上显示错误代码。记录该代码,然后请参阅获得帮助。 | |
代码 | 文本 | 原因 | 更正措施 |
N/A | SYSTEM NAME | 由 62 个字符组成的字符串,可由用户在系统设置程序中定义。 在以下情况下显示 SYSTEM NAME: ∙ 打开系统电源。 ∙ 关闭系统电源并显示活动 POST 错误。 | 此信息仅用于提供信息。 可以在系统设置程序中更改系统 ID 和系统名称。请参阅使用系统设置程序。 |
E1000 | FAILSAFE, Call Support | 请参阅获得帮助。 | |
E1114 | Temp Ambient | 系统周围环境温度超出允许范围。 | 请参阅排除系统冷却故障。 |
E1116 | Temp Memory | 内存已超过允许温度,系统已将其禁用以防止损坏组件。 | 请参阅排除系统冷却故障。 |
E12nn | xx PwrGd | 指定的稳压器出现故障。 | 请参阅获得帮助。 |
E1210 | CMOS Batt | 缺少 CMOS 电池,或电压超出允许范围。 | 请参阅排除系统电池故障。 |
E1211 | ROMB Batt | RAID 电池丢失、损坏或因温度问题而无法再充电。 | 重置 RAID 电池连接器。请参阅 RAID 电池和排除系统冷却故障。 |
E1229 | CPU # VCORE | 处理器 # VCORE 稳压器出现故障。 | 请参阅获得帮助。 |
E1310 | RPM Fan ## | 指定的冷却风扇的 RPM 超出允许的运行范围。 | 请参阅排除系统冷却故障。 |
E1313 | Fan Redundancy | 系统中的风扇不再有冗余。如果风扇再出现故障,系统将有过热危险。 | 检查控制面板 LCD 以获取其它滚动信息。请参阅排除系统冷却故障。 |
E1410 | CPU # IERR | 指定的微处理器报告内部错误。 | 请参阅系统的信息更新技术表(位于 ),以获取最新的系统信息。如果问题仍然存在,请参阅获得帮助。 |
E1414 | CPU # Thermtrip | modal指定的微处理器超出了允许的温度范围并已停止运行。 | 请参阅排除系统冷却故障。如果问题仍然存在,请确保微处理器散热器安装正确。请参阅排除微处理器故障。 注:LCD 将继续显示此信息,直到断开系统的电源线连接并将其重新连接至交流电源,或使用 Server Assistant 或 BMC 管理公用程序清除 SEL 为止。有关这些公用程序的信息,请参阅《Dell OpenManage 底板管理控制器用户指南》。 |
E1418 | CPU # Prence | 指定的处理器丢失或损坏,系统的配置不受支持。 | 请参阅排除微处理器故障。 |
E141C | CPU Mismatch | 处理器的配置不受 Dell 支持。 | 确保您的处理器与系统的《使用入门指南》概述的微处理器技术规格中介绍的型号匹配并相符。 |
E141F | CPU Protocol | 系统 BIOS 已报告处理器协议错误。 | 请参阅获得帮助。 |
E1420 | CPU Bus PERR | 系统 BIOS 已报告处理器总线奇偶校验错误。 | 请参阅获得帮助。 |
E1421 | CPU Init | 系统 BIOS 已报告处理器初始化错误。 | 请参阅获得帮助。 |
E1422 | CPU Machine Chk | 系统 BIOS 已报告机器检查错误。 | 请参阅获得帮助。 |
E1610 | PS # Missing | 指定的电源设备中没有电;指定的电源设备安装错误或出现故障。 | 请参阅排除电源设备故障。 |
E1614 | PS # Status | 指定的电源设备中没有电;指定的电源设备安装错误或出现故障。 | 请参阅排除电源设备故障。 |
E1618 | PS # Predictive | 电源设备电压超出允许范围;指定的电源设备安装错误或出现故障。 | 请参阅排除电源设备故障。 |
E161C | PS # Input Lost | 指定的电源设备的电源不可用,或超出了允许范围。 | 检查指定电源设备的交流电源。如果问题仍然存在,请参阅排除电源设备故障。 |
E1620 | PS # Input Range | 指定的电源设备的电源不可用,或超出了允许范围。 | 检查指定电源设备的交流电源。如果问题仍然存在,请参阅排除电源设备故障。 |
E1624 | PS Redundancy | 电源设备子系统不再有冗余。如果仅有的电源设备出现故障,系统将关闭。 | 请参阅排除电源设备故障。 |
E1710 | I/O Channel Chk | 系统 BIOS 已报告 I/O 通道检查。 | 请参阅获得帮助。 |
E1711 | PCI PERR B## D## F## PCI PERR Slot # | 系统 BIOS 已报告组件的 PCI 奇偶校验错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。 系统 BIOS 已报告组件的 PCI 奇偶校验错误,该组件位于指定的 PCI 插槽。 | 卸下并重置 PCI 扩充卡。如果问题仍然存在,请参阅排除扩充卡故障。 重新安装扩充卡固定框架。请参阅扩充卡固定框架。 如果问题仍然存在,则表示提升卡或系统板出现故障。请参阅获得帮助。 |
E1712 | PCI SERR B## D## F## PCI SERR Slot # | 系统 BIOS 已报告组件的 PCI 系统错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。 系统 BIOS 已报告组件的 PCI 系统错误,该组件位于指定的插槽。 | 卸下并重置 PCI 扩充卡。如果问题仍然存在,请参阅排除扩充卡故障。 重新安装扩充卡固定框架。请参阅扩充卡固定框架。 如果问题仍然存在,则表示提升卡或系统板出现故障。请参阅获得帮助。 |
E1714 | Unknown Err | 系统 BIOS 已确定系统中存在错误,但无法确定错误来源。 | 请参阅获得帮助。 |
E171F | PCIE Fatal Err B## D## F## PCIE Fatal Err Slot # | 系统 BIOS 已报告组件的 PCIe 致命错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。 系统 BIOS 已报告组件的 PCIe 致命错误,该组件位于指定的插槽。 | 卸下并重置 PCI 扩充卡。如果问题仍然存在,请参阅排除扩充卡故障。 重新安装扩充卡固定框架。请参阅扩充卡固定框架。 如果问题仍然存在,则表示提升卡或系统板出现故障。请参阅获得帮助。 |
E1810 | HDD ## Fault | SAS 子系统已确定硬盘驱动器 ## 出现故障。 | 请参阅排除硬盘驱动器故障。 |
E1811 | HDD ## Rbld Abrt | 指定的硬盘驱动器已放弃重建。 | 请参阅排除硬盘驱动器故障。如果问题仍然存在,请参阅 RAID 说明文件。 |
E1812 | HDD ## Removed | 指定的硬盘驱动器已从系统中卸下。 | 仅提供信息。 |
E1913 | CPU & Firmware Mismatch | BMC 固件不支持 CPU。 | 更新至最新的 BMC 固件。有关设置和使用 BMC 的详细信息,请参阅《BMC 用户指南》。 |
E1A11 | PCI Rsr Config | PCI 提升板未正确配置;一些无效配置可能会阻碍系统通电。 | 请参阅扩充卡提升板。 |
E1A12 | PCI Rsr Missing | 一个或所有 PCI 提升板丢失,阻碍系统通电。 | 仅提供信息。 |
E1A14 | SAS Cable A | SAS 电缆 A 丢失或损坏。 | 重置电缆。如果问题仍然存在,请更换电缆。请参阅 SAS 控制器子卡。 |
E1A15 | SAS Cable B | SAS 电缆 B 丢失或损坏。 | 置电缆。如果问题仍然存在,请更换电缆。请参阅 SAS 控制器子卡。 |
E2010 | No Memory | 系统中没有安装内存。 | 安装内存。请参阅安装内存模块。 |
E2011 | Mem Config Err | 检测到内存,但是内存不可配置。配置内存期间检测到错误。 | 请参阅排除系统内存故障。 |
E2012 | Unusable Memory | 已配置内存,但内存不可用。内存子系统出现故障。 | 请参阅排除系统内存故障。 |
E2013 | Shadow BIOS Fail | 系统 BIOS 无法将其快擦写映像复制到内存中。 | 请参阅排除系统内存故障。 |
E2014 | CMOS Fail | CMOS 出现故障。CMOS RAM 未正常工作。 | 请参阅获得帮助。 |
E2015 | DMA Controller | DMA 控制器出现故障。 | 请参阅获得帮助。 |
E2016 | Int Controller | 中断控制器出现故障。 | 请参阅获得帮助。 |
E2017 | Timer Fail | 计时器刷新故障。 | 请参阅获得帮助。 lantis |
E2018 | Prog Timer | 可编程间隔计时器错误。 | 请参阅获得帮助。 |
E2019 | Parity Error | 奇偶校验错误。 | 请参阅获得帮助。 |
E201A | SIO Err | SIO 出现故障。 | 请参阅获得帮助。 |
E201B | Kybd Controller | 键盘控制器出现故障。 | 请参阅获得帮助。 |
E201C | SMI Init | 系统管理中断 (SMI) 初始化失败。 | 请参阅获得帮助。 |
E201D | Shutdown Test | BIOS 关闭系统检测失败。 | 请参阅获得帮助。 |
E201E | POST Mem Test | BIOS POST 内存检测失败。 | 请参阅排除系统内存故障。如果问题仍然存在,请参阅获得帮助。 |
E201F | DRAC Config | Dell 远程访问控制器 (DRAC) 配置失败。 | 请查看屏幕上的具体错误信息。 确保 DRAC 电缆和连接器已正确就位。如果问题仍然存在,请参阅 DRAC 说明文件。 |
E2020 | CPU Config | CPU 配置失败。 | 请查看屏幕上的具体错误信息。 |
E2021 | Memory Population | 内存配置不正确。内存安装顺序不正确。 | 请查看屏幕上的具体错误信息。请参阅排除系统内存故障。 |
E2022 | POST Fail | 视频后出现一般故障。 | 请查看屏幕上的具体错误信息。 |
E2110 | MBE Crd # DIMM ## & ## | “## & ##”指示的 DIMM 组中的一个 DIMM 发生内存多位错误 (MBE)。如果没有内存卡,则“Crd #”字符串将留在信息外。 | 请参阅排除系统内存故障。 |
E2111 | SBE Log Disable Crd # DIMM ## | 系统 BIOS 已禁用内存单位错误 (SBE) 记录,在重新引导系统之前,不会再记录更多的 SBE。“##”表示 BIOS 指示的 DIMM。如果没有内存提升卡,则“Crd #”字符串将留在信息外。 | 请参阅排除系统内存故障。 |
E2112 | Mem Spare Crd # DIMM ## | 系统 BIOS 确定内存中有太多错误,因此已将内存释放。“## & ##”表示 BIOS 指示的 DIMM 对。如果没有内存卡,则“Crd #”字符串将留在信息外。 | 请参阅排除系统内存故障。 |
E2113 | Mem Mirror Crd # DIMM ## & ## | 系统 BIOS 确定一半镜像中有太多错误,因此已将内存镜像禁用。“## & ##”表示 BIOS 指示的 DIMM 对。如果没有内存卡,则“Crd #”字符串将留在信息外。 | 请参阅排除系统内存故障。 |
E2118 | Fatal NB Mem CRC | 北侧的全缓冲 DIMM (FBD) 内存子系统链接中的一个连接失败。 | 请参阅排除系统内存故障。 |
E2119 | Fatal SB Mem CRC | 南侧的 FBD 内存子系统链接中的一个连接失败。 | 请参阅排除系统内存故障。 |
I1910 | Intrusion | 主机盖被卸下。 | 仅提供信息。 |
I1911 | >3 ERRs Chk Log | LCD 溢出信息。 LCD 上最多只能按顺序显示三条错误信息。第四条信息显示为标准的溢出信息。 | 查看 SEL 以获取事件详细信息。 |
I1912 | SEL Full | 系统事件日志中的事件已满,无法再记录更多事件。 | 通过删除事件条目清除日志。 |
W1228 | ROMB Batt < 24hr | 预先警告 RAID 电池只剩下不足 24 小时的电量。 | 更换 RAID 电池。请参阅 RAID 电池。 |