Cable and Board Prence - Message Code: "x1Axx" | ||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? |
E1A10 | PDBPwrCable | High | PDB power cable to the planar is missing or bad and system will not power on. | Failing device is reated/replaced/repaired. | Yes | Pre-Post |
E1A11 | PCIRsrConfig | High | PCI rirs are not configured correctly; some invalid configurations prevent system power on. | Failing device is reated/replaced/repaired. | Yes | Pre-Post |
E1A12 | PCIRsrMissing | High | One or all of the PCI rirs is missing. This prevents system power on. | Failing device is reated/replaced/repaired. | Yes | Pre-Post |
E1A14 | SAS Cable A | Low | SAS cable A is missing or bad. | Failing device is reated/replaced/repaired. | Yes | Any |
E1A15 | SAS Cable B | Low | SAS cable B is missing or bad. | Failing device is reated/replaced/repaired. | Yes | Any |
E1A16 | SAS Cable FB | Low | Flex bay SAS cable is missing or bad. | Failing device is reated/replaced/repaired. | Yes | Any |
E1A17 | PwrCable FB | Low | Flex bay power cable is missing or bad. | Failing device is reated/replaced/repaired. | Yes | Any |
E1A18 | PDBCtrl Cable | aircargoHigh | PDB control cable to the planar is missing or bad and system will not power on. | Failing device is reated/replaced/repaired. | Yes | Any |
Temperature - Message Code: "x11xx" | ||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? |
E1114 | Temp Ambient | Med | Ambient temperature has a reached a point outside of the allowed range. | Temperature returns to allowable range. | Yes | Any |
E1116 | Temp Memory | High | Memory has exceeded allowable temperature and has been disabled to prevent damage to the components. | AC Cycle or SEL clear | Yes | Any |
glow |
Voltages - Message Code: "x12xx" | ||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? |
E1210 | CMOSBatt | Low | CMOS battery is missing or the voltage is outside of the allowable range. | Failing device is reated/replaced/repaired. | Yes | Any |
E1211 | ROMBBatt | Low | PERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly becau of high temperatures), or the battery is bad. | Failing device is reated/replaced/repaired. | Yes | Any |
W1228 | ROMBBatt< 24 hr | Low | This is a predictive failure warning message telling the ur that the PERC5I RAID battery has less then 24 hours of charge left init. We provide this message as a warning message to the customer. | Battery charges to > 24 hours of sustained charge. | Yes | Any |
E1214 | 1.5VPwrGd | High | 1.5 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1215 | 1.8VPwrGd | High | 1.8 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1216 | 3.3VPwrGd | High | 3.3 V voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1217 | 5VPwrGd | High | 5 V voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1218 | PCIRsr5VPwrGd | High | PCI Rir 5 V voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1219 | BackplanePwrGd | High | Backplane voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1221 | Flex BayPwrGd | High | Flex Bay voltage regulator power good has failed. | AC Cycle or SEL clear | Yes | Any |
E1222 | VCACHE #PwrGd | High | VCACHE # voltage regulator has failed. | AC Cycle or SEL clear | chimesYes | Any |
值此之际 E1223 | VRM #PwrGd | High | VRM # voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1225 | ESB 1.5VPwrGd | High | ESB 1.5 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Anywww tingclass com |
E1226 | PCIRsr1.5VPwrGd | High | PCI Rir 1.5 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1227 | LinearPwrGd | High | Linear voltage regulator(s) has failed. Reprents status of multiple voltage regulators ud in the video and LOM circuitry. | AC Cycle or SEL clear | Yes | Any |
E1228 | 0.9VPwrGd | High | Memory VTT voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1229 | CPU # VCORE | High | Processor # VCORE voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E122A | CPU VTTPwrGd | High | Processor VTT voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E122B | 0.9 V Over Voltage | High | 0.9 V regulator voltage has exceeded the allowable voltage range. | AC Cycle or SEL clear | Yes | Any |
E122C | CPU Power Fault | High | A voltage regulator failure was detected when the processor regulator(s) was enabled. | AC Cycle or SEL clear | Yes | Any |
Fans - Message Code: "x13xx" | ||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? |
E1310 | RPM Fan ## | Low | RPM of fan ## is outside of the intended operating range. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any |
E1311 | RPM Fan Mod #A | Low | RPM of fan A in the # module is outside of the intended operating range. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any |
E1311 | RPM Fan Mod #B | Low | Same as above except for fan B of module #. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any |
E1311 | RPM Fan Mod #C | Low | Same as above except for fan C of module #. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | 宽宥Any |
E1311 | RPM Fan Mod #D | Low | Same as above except for fan D of module #. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any |
E1313 | Fan Redundancy | Low | The system is no longer fan redundant. Another fan failure would put the system at risk of over-heating. | Fan redundancy is regained, which requires all fans to be operating within the intended operating range. | Yes | Any |
Processors - Message Code: "x14xx" | ||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? |
E1410 | CPU # IERR | High | Processor # has had an internal error (IERR), but this does not always mean that CPU is the problem .There are a large variety of issues that cau an IERR. | AC Cycle or SEL clear | Yes | Any |
E1414 | CPU #Thermtrip | High | Processor # has encountered a Thermtrip(over-temperature) event. | AC Cycle or SEL clear | Yes | Any |
E1418 | CPU # Prence | High | Processor # is missing/bad and the system is in an unsupported configuration. | AC Cycle or SEL clear | Yes | Pre-POST |
E141C | CPU Mismatch | High | Processors are not compatible as defined by Dell .System is in an unsupported configuration. | AC Cycle or SEL clear | 初学者怎样化妆Yes | Pre-POST |
E141F | CPU Protocol | High | BIOS has reported a processor protocol error. | AC Cycle or SEL clear | 槽道Yes | POST, After POST |
E1420 | CPU Bus PERR | High | BIOS has reported a processor bus PERR (parity error). | AC Cycle or SEL clear | Yes | POST, After POST |
E1421 | CPU Init | High | BIOS has reported a processor initialization error. | AC Cycle or SEL clear | Yes | POST, After POST |
E1422 | CPU MachineChk | High | BIOS has reported a machine check error. | AC Cycle or SEL clear | Yes | POST, After POST |
System Memory - Message Code: "x21xx" | ||||||
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Pha When Event Can Occur? |
E2110 | MBECrdx DIMM ## & ## | High | One of the DIMMs in the t implicated by "## & ##" has had a multi-bit error (MBE).If no memory rir is prent the “Crdx” string is left out of the message.“x” is the memory rir, A-Z. | AC Cycle or SEL clear | Yes | POST, After POST |
E2111 | SBE Log DisableCrdx DIMM ## | High | BIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEE's until the system is rebooted.## reprents DIMM implicated by BIOS .If no memory rir is prent the “Crd x” string is left out of the message.“x” is the memory rir, A-Z. | System ret | Yes | POST, After POST |
E2112 | MemSpareCrdx DIMM ## | High | BIOS has spared the memory becau it has determined the memory had too many errors.## reprents DIMM implicated by BIOS. If no memory rir is prent the “Crdx” string is left out of the message.“x” is the memory rir, A-Z. | System ret | Yes | POST, After POST |
E2113 | Mem Mirror Crd x DIMM ## & ## | High | BIOS has disabled memory mirroring becau it has determined one half of the mirror has had too many errors. ## & ## reprents DIMM pair implicated by BIOS. If no memory rir is prent the “Crdx” string is left out of the message.“x” is the memory rir, A-Z. | System ret | Yes | 紫色配什么色好看POST, After POST |
I2114 | MemRaid | Low | BIOS Memory RAID Bank | Ur action, nsor return to normal 低碳生活从我做起 | Yes | Any |
I2115 | MemAdded Card x | Low | Memory has been added while the system is running. | AC Cycle or SEL clear | Yes | Any |
I2116 | MemRemoved | Low | Memory has been removed while the system is running. | AC Cycle or SEL clear | Yes | Any |
E2117 | MemHot Plug | Low | Memory hot-plug operation has failed. | AC Cycle or SEL clear | Yes | Any |
E2118 | Fatal NBMemCRC | High | Northbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row. | AC Cycle or SEL clear | Yes | POST, After POST |
E2119 | Fatal SBMemCRC | High | FBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMB'son the FBDIMM's) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row. | AC Cycle or SEL clear | Yes | POST, After POST |