Dell服务器常见故障代码说明

更新时间:2023-05-20 14:27:21 阅读: 评论:0

Dell的服务器错误代码
 
aircargo
Cable and Board Prence - Message Code: "x1Axx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1A10
PDBPwrCable
High
PDB power cable to the planar is missing or bad and system will not power on.
Failing device is reated/replaced/repaired.
Yes
Pre-Post
E1A11
PCIRsrConfig
High
PCI rirs are not configured correctly; some invalid configurations prevent system power on.
Failing device is reated/replaced/repaired.
Yes
Pre-Post
E1A12
PCIRsrMissing
High
One or all of the PCI rirs is missing. This prevents system power on.
Failing device is reated/replaced/repaired.
Yes
Pre-Post
E1A14
SAS Cable A
Low
SAS cable A is missing or bad.
Failing device is reated/replaced/repaired.
Yes
Any
E1A15
SAS Cable B
Low
SAS cable B is missing or bad.
Failing device is reated/replaced/repaired.
Yes
Any
E1A16
SAS Cable FB
Low
Flex bay SAS cable is missing or bad.
Failing device is reated/replaced/repaired.
Yes
Any
E1A17
PwrCable FB
Low
Flex bay power cable is missing or bad.
Failing device is reated/replaced/repaired.
Yes
Any
E1A18
PDBCtrl Cable
High
PDB control cable to the planar is missing or bad and system will not power on.
Failing device is reated/replaced/repaired.
Yes
Any
glow
Temperature - Message Code: "x11xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1114
Temp Ambient
Med
Ambient temperature has a reached a point outside of the allowed range.
Temperature returns to allowable range.
Yes
Any
E1116
Temp Memory
High
Memory has exceeded allowable temperature and has been disabled to prevent damage to the components.
AC Cycle or SEL clear
Yes
Any
chimes
Voltages - Message Code: "x12xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1210
CMOSBatt
Low
CMOS battery is missing or the voltage is outside of the allowable range.
Failing device is reated/replaced/repaired.
Yes
Any
E1211
ROMBBatt
Low
PERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly becau of high temperatures), or the battery is bad.
Failing device is reated/replaced/repaired.
Yes
Any
W1228
ROMBBatt< 24 hr
Low
This is a predictive failure warning message telling the ur that the PERC5I RAID battery has less then 24 hours of charge left init. We provide this message as a warning message to the customer.
Battery charges to > 24 hours of sustained charge.
Yes
Any
E1214
1.5VPwrGd
High
1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1215
1.8VPwrGd
High
1.8 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1216
3.3VPwrGd
High
3.3 V voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1217
5VPwrGd
High
5 V voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1218
PCIRsr5VPwrGd
High
PCI Rir 5 V voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1219
BackplanePwrGd
High
Backplane voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1221
Flex BayPwrGd
High
Flex Bay voltage regulator power good has failed.
AC Cycle or SEL clear
Yes
Any
E1222
VCACHE #PwrGd
High
VCACHE # voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
值此之际
E1223
VRM #PwrGd
High
VRM # voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1225
ESB 1.5VPwrGd
High
ESB 1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Anywww tingclass com
E1226
PCIRsr1.5VPwrGd
High
PCI Rir 1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1227
LinearPwrGd
High
Linear voltage regulator(s) has failed. Reprents status of multiple voltage regulators ud in the video and LOM circuitry.
AC Cycle or SEL clear
Yes
Any
E1228
0.9VPwrGd
High
Memory VTT voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1229
CPU # VCORE
High
Processor # VCORE voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E122A
CPU VTTPwrGd
High
Processor VTT voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E122B
0.9 V Over Voltage
High
0.9 V regulator voltage has exceeded the allowable voltage range.
AC Cycle or SEL clear
Yes
Any
E122C
CPU Power Fault
High
A voltage regulator failure was detected when the processor regulator(s) was enabled.
AC Cycle or SEL clear
Yes
Any
Fans - Message Code: "x13xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1310
RPM Fan ##
Low
RPM of fan ## is outside of the intended operating range.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #A
Low
RPM of fan A in the # module is outside of the intended operating range.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #B
Low
Same as above except for fan B of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #C
Low
Same as above except for fan C of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
宽宥Any
E1311
RPM Fan Mod #D
Low
Same as above except for fan D of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1313
Fan Redundancy
Low
The system is no longer fan redundant. Another fan failure would put the system at risk of over-heating.
Fan redundancy is regained, which requires all fans to be operating within the intended operating range.
Yes
Any
Processors - Message Code: "x14xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E1410
CPU # IERR
High
Processor # has had an internal error (IERR), but this does not always mean that CPU is the problem .There are a large variety of issues that cau an IERR.
AC Cycle or SEL clear
Yes
Any
E1414
CPU #Thermtrip
High
Processor # has encountered a Thermtrip(over-temperature) event.
AC Cycle or SEL clear
Yes
Any
E1418
CPU # Prence
High
Processor # is missing/bad and the system is in an unsupported configuration.
AC Cycle or SEL clear
Yes
Pre-POST
E141C
CPU Mismatch
High
Processors are not compatible as defined by Dell .System is in an unsupported configuration.
AC Cycle or SEL clear
初学者怎样化妆Yes
Pre-POST
E141F
CPU Protocol
High
BIOS has reported a processor protocol error.
AC Cycle or SEL clear
槽道Yes
POST, After POST
E1420
CPU Bus PERR
High
BIOS has reported a processor bus PERR (parity error).
AC Cycle or SEL clear
Yes
POST, After POST
E1421
CPU Init
High
BIOS has reported a processor initialization error.
AC Cycle or SEL clear
Yes
POST, After POST
E1422
CPU MachineChk
High
BIOS has reported a machine check error.
AC Cycle or SEL clear
Yes
POST, After POST
紫色配什么色好看
System Memory - Message Code: "x21xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Pha When Event Can Occur?
E2110
MBECrdx DIMM ## & ##
High
One of the DIMMs in the t implicated by "## & ##" has had a multi-bit error (MBE).If no memory rir is prent the “Crdx” string is left out of the message.“x” is the memory rir, A-Z.
AC Cycle or SEL clear
Yes
POST, After POST
E2111
SBE Log DisableCrdx DIMM ##
High
BIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEE's until the system is rebooted.## reprents DIMM implicated by BIOS .If no memory rir is prent the “Crd x” string is left out of the message.“x” is the memory rir, A-Z.
System ret
Yes
POST, After POST
E2112
MemSpareCrdx DIMM ##
High
BIOS has spared the memory becau it has determined the memory had too many errors.## reprents DIMM implicated by BIOS. If no memory rir is prent the “Crdx” string is left out of the message.“x” is the memory rir, A-Z.
System ret
Yes
POST, After POST
E2113
Mem Mirror Crd x DIMM ## & ##
High
BIOS has disabled memory mirroring becau it has determined one half of the mirror has had too many errors. ## & ## reprents DIMM pair implicated by BIOS. If no memory rir is prent the “Crdx” string is left out of the message.“x” is the memory rir, A-Z.
System ret
Yes
POST, After POST
I2114
MemRaid
Low
BIOS Memory RAID Bank
Ur action, nsor return to normal
低碳生活从我做起
Yes
Any
I2115
MemAdded Card x
Low
Memory has been added while the system is running.
AC Cycle or SEL clear
Yes
Any
I2116
MemRemoved
Low
Memory has been removed while the system is running.
AC Cycle or SEL clear
Yes
Any
E2117
MemHot Plug
Low
Memory hot-plug operation has failed.
AC Cycle or SEL clear
Yes
Any
E2118
Fatal NBMemCRC
High
Northbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.
AC Cycle or SEL clear
Yes
POST, After POST
E2119
Fatal SBMemCRC
High
FBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMB'son the FBDIMM's) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.
AC Cycle or SEL clear
Yes
POST, After POST