The OFFand the EMERGENCY STOP buttons are connected in ries between terminals S11 and S12/S22 (Category 3) the auxiliary supply is connected to terminals A1(+) A2(–).The circuits to be tripped may be connected to terminals13-14, 23–24 and 33–34. If remote signalling is required then terminals 41-42 may be ud. When the EMERGENCY STOP button is activated power is removed from terminals S12/S22, relays K2, K3 are de-energid and contacts 13–14, 23–24 and 33–34 open.
The relay is equipped with three green LEDs. When illuminated they indicate the healthy condition of the auxiliary supply and circuits K2 – K3.
•Category 3 or 4 switch programmable,  SIL CL3•Contacts 3 N/O, 1 N/C (5  m gold plated)
•Removable terminal strips for fast replacement •Compact 45 mm wide ca
•Internal auxiliary power supply protection with automatic ret •
AC or 24V DC auxiliary power supply options
•Switch programmable single or dual channel operation,
auto or manual ret with short circuit/link monitoring of
E-stop and ret push-buttons.
Emergency stop relay BD 5935 complies fully with the requirements of the standard specifications referred to on page X. The unit is houd  in a compact 45 mm wide ca suitable for DIN rail mounting and is available in a wide range of auxiliary voltages. It differs from the  BN 5983described previously in that it employs fail-safe electronic circuitry for the lf checking and short circuit/link monitoring features  and has two switches under the front plate to enable the lection of:
Switch 1 -  Cross fault monitoring of E-Stop circuits (Category  4).Switch 2 -  Auto or manual ret
It is recommended that redundancy is carried through to the EMERGENCY STOP button by using a dual contact button as shown.If a single contact button is ud then terminals S12 and S22 should be bridged (Category 2 applications only).
To lect required function remove front cover with screwdriver (e diagram page X) and t switches to the desired position.
CANADA USA
of Electrical Engineer-ing
Model BD 5935.48
CFM
OFF
ON AUTO
MANUAL
(Cross Fault monitoring)
Weight 0.45 Kg
2
3
Nominal Voltage (Vn)
24, 48,110,127, 230V ac or 24V dc (To Be Specified)
Burden <5VA ac/3W 24V dc
Voltage Tolerance 0·8 –1·1 Vn ac, 0·8–1·2 Vn dc
Frequency 50 to 60Hz ±5%Control Voltage 24V dc (S11)
Min. Return Voltage 18·5V dc (S12/S22)
Contacts Gold plated 5 microns
3 N/O, 1 N/C
Max Switching Capacity 10A ac (cos ø 1 - 0·7)
10A dc  See  page  xx
Continuous  Current  Rating See  page  xx
Contact  Life  Mechanical 30  x 106  operations Contact  Life  Electrical See  page  xx
Derated Capacity AC15, 6A, 250V ac
(for Heavy Inductive Loads)DC13, 6A, 24V dc Min Switching Voltage & Current 0·1 – 60V, 1–300mA
Max Switching Voltage 250V ac, 250V dc
Max Switching Power 2500VA (AC1)/240W dc Max Switching Frequency 6000 operations/hour
Max Loop Resistance 110Ω
S11/S12–S22
Dual Channel Operation
Reaction Times Manual Ret 100ms
Auto Ret 900ms E-STOP<20ms
Operating T
emperature –15°C...+55°C at 90% RH
Protection Class Ca IP40 T erminals IP20
Test Voltage 2·5KV 1 minute Shock Loading Amplitude 0·35mm
Frequency 10–55Hz (5g @ 50Hz)
Enclosure Material Thermoplastic VO Rating UL94
T erminations    1 x 4mm 2 solid
2 x 2·5mm 2 solid
1 x 2·5mm
2 stranded ferruled 1 x 1·5mm 2 stranded
Information Required With Order • Model type • Auxiliary supply
Example: Emergency Stop Relay Type BD 5935.48Auxiliary Supply 230V 50Hz