盐雾测试报告 中英文对照全面

更新时间:2023-05-09 04:05:06 阅读: 评论:0

1. Test diagram & test method  测试图示和方法
2. Test  result 测试结果
5PCS
/
2014-9-21
Salt spray test machine  DJS-EN61盐雾试验机:DJS-GU-358Test environment 测试环境Drawing NO.
工程图号HDMI M/M Ni Plated 30AWG OD:5.0 L=1.5/2.0M  Black
/Sample Q'ty 样品数量
Part/No.产品料号Test machine 测试设备温度:28℃/湿度:75%
SHENZHEN EAST-TOPTECH ELECTRONIC TECHNOLOGY CO.,LTD
深圳市东景盛电子技术有限公司
Salt spray Test Report  盐 雾 测 试 报 告
Product name 产品名称
Product spec.
产品规格
HDMI AM TO AM 30AWG 1.4REV. OD :5.0mm  Length :1.5/2.0M
Customer 客户名称/
Test date 测试日期
Note 备注
According to GB/T10125-1997OK Sample No.
OK Test result description 结果描述
Judgement 综合判定
2#3#4#Test Item 测试项目
Salt spray test 盐水喷雾试验
Result of measurement 测 试 结 果
Test  Requirement  测 试 要 求
6.8Reference 参考
6.5~
7.235±2℃35±2℃1.0-2.0ml(80cm 2
/H)
5#■ PASS 合格                      □ NG 不合格
After ( 24 ) hours, test surface has no  red phenomenon such as corrosion, bubble, crack After ( 24 ) hours, test surface has no  red phenomenon such as corrosion, bubble, crack After ( 24 ) hours, test surface has no  red phenomenon such as corrosion, bubble, crack
OK OK OK
Judgement 判定
35℃35℃1.00KG/CM 2
25°GB/T10125-1997
1.5ml 24H
After the test, take out the sample on the interior, natural drying 0.5 1 h, and then u clean flow of temperature is not higher than 35 ℃ water gently cleaning to remove the sample surface residual salt spray solution, then blow dry.试验结束后,取出试样放在室内,自然干燥0.5-1H,然后用温度不高于35℃的清洁流动水轻轻清洗以除去试样表面残留的盐雾溶液,再用吹风机吹干。
To 20 times a magnifying glass to obrve, the surface has no red
phenomenon such as corrosion, bubble, crack, Judged to be qualified 。以20倍放大镜观察,表面无红色腐蚀物、气泡、裂纹等现象,即判定合格.After ( 24 ) hours, test surface has no  red phenomenon such as corrosion, bubble, crack After ( 24 ) hours, test surface has no  red phenomenon such as corrosion, bubble, crack Actual record 实际记录值
5%1#47℃85﹪RH
Collected volume of salt spray  盐雾收集量Test time  试验时间
2014-9-21 : 8:00
~2014-9-22 :8:00
Saturated air barrel temperature 饱和压力桶温度Test room relative humidity  试验室相对湿度Pressure of compresd air 压缩空气压力Sample place angle 样品放置角度47±1℃85±2%RH 1.00±0.01KG/CM
2
15~30°Salt solution barrel temperature 盐水桶温度Setting 设置5±1%Condition items 条件项目
Concentration of salt solution 盐水浓度PH of salt solution  PH 值
Test room Temperature 试验室温度 表单编号:DJS-QR-045