The latest addition to a whole new generation of alternators, this range benefits from the experience of the leading manufacturer worldwide, using advanced technology and incorporating strict quality control. SAFETY MEASURES
Before using your machine for the first time, it is important to read the whole of this installation and maintenance manual.
All necessary operations and interventions on this machine must be performed by a qualified technician.
Our technical support rvice will be plead to provide any additional information you may require.
The various operations described in this manual are accompanied by recommendations or symbols to alert the ur to potential risks of accidents. It is vital that you understand and take notice of the following warning symbols. Warning symbol for an operation capable of damaging or destroying the machine or surrounding equipment.
Warning symbol for general danger to personnel. Warning symbol for electrical danger to personnel. Note : LEROY-SOMER rerves the right to modify the characteristics of its products at any time in order to incorporate the latest technological developments. The information contained in this document may therefore be changed without notice.We wish to draw your attention to the contents of this maintenance manual. By following certain important points during installation, u and rvicing of your alternator, you can look forward to many years of trouble-free operation.
WARNING SYMBOLS
A t of lf-adhesive stickers depicting the various warning
symbols is included with this maintenance manual. They
should be positioned as shown in the drawing below once the
machine has been fully installed.
Copyright 2004 : MOTEURS LEROY-SOMER
This document is the property of :
MOTEURS LEROY-SOMER
It may not be reproduced in any form without prior
authorization.
All brands and models have been registered and patents
applied for.
2
1 - RECEIPT
古代日本1.1 - Standards and safety measures (4)
1.2 - Checks (4)
1.3 - Identification (4)
1.4 - Storage (4)
2 - TECHNICAL CHARACTERISTICS
2.1 - Electrical characteristics (5)
2.2 - Mechanical characteristics (5)
3 - INSTALLATION - COMMISSIONING
3.1 - Asmbly (6)
中药菟丝子3.2 - Inspection prior to first u (6)
3.3 - Electrical diagram (7)
3.4 - Commissioning (9)
3.5 - 94 - SERVICING - MAINTENANCE
4.1 - Safety measures (10)
4.2 - Regular maintenance (10)
4.3 - Fault detection (10)
4.4 - Mechanical defects (11)
4.5 - Electrical faults (11)
4.6 - Dismantling, reasmbly (13)
4.7 - Characteristics table (15)
5 - SPARE PARTS
5.1 - First maintenance parts (16)
5.2 - Description of bearings (16)
家长帮社区论坛
5.3 - Technical support rvice (16)
5.4 - Exploded view, parts list (17)
3
1 - RECEIPT
1.1 - Standards and safety measures Our alternators comply with most international standards and are compatible with :
- the recommendations of the
International Electrotechnical Commission
IEC 34-1, (EN 60034).
- the recommendations of the
International Standards Organisation ISO 8528.
梦随心动- the European Community directive 89/336/EEC on Electromagnetic Compatibility (EMC).
- the European Community directives 73/23/EEC and
93/68/EEC (Low Voltage Directive).
They are CE marked with regard to the LVD (Low Voltage Directive) in their role as a machine component. A declaration of incorporation can be supplied on request.
Before using your generator for the first time, read carefully the contents of this installation and maintenance manual, supplied with the machine. All operations performed on the generator should be undertaken by qualified personnel with specialist training in the commissioning, rvicing and maintenance of electrical and mechanical machinery. This maintenance manual should be retained for the whole of the machine’s life and be handed over with the contractual file. The various operations described in this manual are accompanied by recommendations or symbols to alert the ur to potential risks of accidents. It is vital that you understand and take notice of the different warning symbols.
1.2 - Inspection
On receipt of your alternator, check that it has not suffered any damage in transit. If there are obviou
s signs of knocks, contact the transporter (you may able to claim on their insurance) and after a visual check, turn the machine by hand to detect any malfunction. 1.3 - Identification
The alternator is identified by means of a nameplate fixed on the frame.
Make sure that the nameplate on the machine conforms to your order.
The machine name is defined according to various criteria (e below).
Example of description for : LSA 42.2 S4 J6/4 -
• LSA : name ud in the PARTNER range
M : Marine / C : Cogeneration / T  : Telecommunications.• 42.2 : machine type
• S4 : model
• J :field excitation system
(C:AREP / J:SHUNT /  E:COMPOUND)
• 6/4 :  winding number / number of poles.
1.3.1 - Nameplate
So that you can identify your machine quickly and accurately, we suggest you fill in its specifications on the nameplate below.
1.4 -  Storage
Prior to commissioning, machines should be stored :
- Away from humidity : in conditions of relative humidity of more than 90%, the machine insulation can drop very rapidly, to just above zero at around 100%; monitor the state of the anti-rust protection on unpainted parts.
For storage over an extended period, the machine can be placed in a aled enclosure (heatshrunk plastic for example) with dehydrating sachets inside, away from significant and frequent variations in temperature to avoid the risk of condensation during storage.
- If the area is affected by vibration, try to reduce the effect of the vibrations by placing the generator on a damper support (rubber disc or similar) and turn the rotor a fraction of a turn once a fortnight to avoid marking the bearing rings.
4
LSA 42.2 - 2 & 4 POLE
ALTERNATORS
TECHNICAL CHARACTERISTICS
2 - TECHNICAL CHARACTERISTICS
2.1 -  Electrical characteristics
The PARTNER LSA 42.2 alternator is a machine without认认真真的近义词
sliprings and revolving field brushes, wound as "2/3 pitch";
12-wire, with class H insulation and a field excitation system
available in either "SHUNT" or "AREP" version (e ctions
2.3, 2.4). Interference suppression conforms with standard
EN 55011, group 1, class B.
三年级上册数学日记2.1.1 - Options
- Stator temperature detection probes.
- Space heaters.
2.2 - Mechanical characteristics
-
  Steel frame
-  End shields in cast iron
-  Greasable ball bearings
-  Mounting arrangement
MD 35 :
single bearing with standard feet and SAE flanges/coupling discs.
B 34 :
two-bearing with SAE flange and standard cylindrical shaft extension.
- Drip-proof machine, lf-cooled - Degree of protection : IP 23
2.2.1 - Options
- Protection against harsh environmentsh.
-
Air input filter, air output labyrinth cowling.
Alternators fitted with air inlet filters should be derated by 5% (power)
To prevent excessive temperature ri caud by clogged filters, it is advisable to fit the stator winding with thermal nsors (PTC or PT100).
.