•Installation
•Commissioning
•Owners (warranty) FOR ADVICE, REPAIRS AND SERVICE:
CALL
1300 365 115 (AUSTRALIA)
0800 729 389 (NZ)
Effective for Airoheat Hot Water Heaters manufactured and sold after 1st June 2006.
Specifications and materials may change without notice
Part No: H3023
CONTENTS
WELCOME TO DUX HOT (3)
1.0INSTALLATION DETAILS (4)
LOCATION (4)
PREFERRED LOCATION (5)
NOISE CONSIDERATIONS (6)
AIR FLOW (6)
TRANSPORTATION (6)
PLUMBING CONNECTIONS (7)
STORAGE TANK INSTALLATION (7)
PRESSURE & TEMPERATURE RELIEF  VALVE (7)
COLD WATER CONNECTION (7)
HOT WATER CONNECTION (8)
FILLING THE SYSTEM WITH WATER (8)
ELECTRICAL CONNECTION (8)
WATER QUALITY (9)
INSTALLATION CHECK POINTS (10)
车窗外
2.0COMMISSIONING THE SYSTEM (11)
OPERATIONAL DIAGRAM (12)
COMMISSIONING CHECK POINTS (13)
3.0 OWNERS INSTRUCTIONS (14)
敬业乐群
HOW DOES THE HEAT PUMP MODULE WORK? (14)
HOW DO I OPERATE THE SYSTEM? (14)
HOW LONG WILL THE HEAT PUMP RUN EACH DAY? (15)
WHY IS THERE CONDENSATION COMING FROM THE AIROHEAT? (15)
DOES THE HEAT PUMP NEED SUNLIGHT TO OPERATE? (15)
WHAT SHOULD I DO DURING HOLIDAYS? (16)
WHAT SHOULD I CHECK BEFORE MAKING A SERVICE CALL? (16)
FAULT FINDING (16)
SYSTEM MAINTENANCE (17)
SAFETY INFORMATION (18)
SERVICE INFORMATION (19)
SIX MONTHLY SERVICE-BY OWNER (19)
FIVE YEAR SERVICE - BY AUTHORISED PERSONNEL ONLY (19)
WARRANTY (20)
SCOPE OF WARRANTY AND GUARANTEE (20)
WARRANTY CARD (22)
APPLIANCE DETAILS (22)
INSTALLER’S DETAILS (22)
SERVICE DETAILS (22)
WELCOME TO DUX HOT
Your decision to purcha a Dux Hot Water system will reward you for many years to come.
Since 1915, the Dux range has en continuous rearch and development, resulting in many breakthroughs in the efficiency, reliability and longevity of hot water systems.
Dux water heaters are manufactured in Australia in a state-of-the-art facility, using a Quality Endord Company production system.
This is your assurance that you have purchad the highest quality water heater available, one that will provide continuous hot water for all your needs - safely, economically, and for many years to come.
To be upfront about it, we want Dux to be your brand of choice. So you can depend on us to provide more than just a hot water system.
You can rely on Dux products and choo them with confidence. We’ll make sure you have the information, the quality and the innovation you’re looking for, including the latest energy-saving alternatives. If you should ever have a problem – and we’ll bet you won’t – you’ll find that we’re easy to get hold of, friendly to talk to and quick to act. Our rvice is all about providing anything you need as soon as you need it.
Go with Dux and you’ll have a dependable, economical, efficient hot water system designed to perform well, year after year. And that’s a promi.
1.0 INSTALLATION DETAILS
This water heater must be installed by a licend tradesperson, and in accordance with:
• AS/NZS3500.4.2 “National Plumbing and Drainage Code Hot Water Supply Systems – Acceptable Solutions” .
•Local authority regulations.
•Outside Australia and New Zealand, plea refer to local plumbing and building codes and regulations.
• Notice to Victorian customers from the Victorian Plumbing Industry Commission – this water heater must be installed by a licend person as required by the Victorian Building Act 1993. Only a licend person will give you a compliance certificate, showing that the work complies with all the relevant Standards and only a licend person will have insurance protecting their workmanship for 6 years.
NOTE:  This water heater and heat pump components are not suitable
for pool heating.
夜空上最亮的星
All warranty is voided if the unit is laid on its side for storage or
transport.  It must be stored and transported in a near vertical position
at all times, there are no exceptions.
This water heater is designed for direct connection to water supply pressures of no greater than:
•250 Litre Model  - 1000kPa
Where the mains pressure can exceed or fluctuate beyond the pressure shown above a pressure limiting device (complying with AS1357) must be fitted in the cold water inlet supply.  This device must be installed after the isolating valve and t at or below the pressure shown above. Note during periods of lower demand water pressure may increa.
CAUTION:  This water heater delivers hot water at temperatures
荣联合
exceeding 50o C.  Refer to AS/NZS3500 and local regulations regarding
the need for additional temperature control of hot water delivery.
黄庭坚简介
LOCATION
The water heater should be located as clo as possible to the most frequently ud hot water outlet.  Ensure that the data plate is clearly visible and provide adequate access for rvice to the element, thermostat, relief valve and anode.
NOTE:  All models are equipped with a sacrificial anode, accessible
through the top cover.  Allow 50% of the height of the water heater for
clearance above to replace the anode.
The water heater has a plastic ba which is resistant to water damage but it is recommended that a concrete plinth be installed under the water heater to protect the heater when subjected to wet conditions. A properly drained overflow tray must be ud where property damage could occur from water spillage.  (See AS/NZS3500.4.2 for further details.)
NOTE:The warranty does not cover conquential damage due to leakage of the water heater.
PREFERRED LOCATION
If possible the location lected for the
heat pump should be on the warm side of
the home.
The lected location must have free
ambient air flow to prevent cooler
discharged air being drawn back into the
heat pump.
Allow sufficient clear space so as not to
impede this air flow. Allow 700 mm
clearance above the Airoheat and allow
150mm clearance to either side of the
Airoheat as a general rule.北海侨港
NOISE CONSIDERATIONS
The lected location must consider noi impact on living areas, especially bedrooms, inside the hou. Although the running noi level is very low (50
dB(A)) it can be expected that the heat pump will run during the night.
The installer can assist in choosing the appropriate location for the Airoheat.
.
美国大学排名一览表AIR FLOW
Ensure the unit is placed in an area were debris
地球为什么是圆的
such as leaves and paper etc, will not collect and
block the air outlet on the top of the unit.
IMPORTANT! Do not put any objects on top of
the Airoheat unit.
TRANSPORTATION
Ensure the Airoheat is always stored and
transported in an upright position.
NOTE: All warranty is voided if the unit is laid on
its side for storage or transport.  It must be stored
and transported in a near vertical position at all
times, there are no exceptions.

本文发布于:2023-05-27 02:17:02,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/89/935210.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:美国   一览表
相关文章
留言与评论(共有 0 条评论)
   
验证码:
推荐文章
排行榜
Copyright ©2019-2022 Comsenz Inc.Powered by © 专利检索| 网站地图