港口 | 莫比乌斯圈代码 | Nature of Deficiency | 处理 |
NEW ORLEANS | 07120 | Self closing mechanism on the engine room bottom level emergency escape fire door was broken and prevented the door from closing complete. (ISM)机舱应急逃生通道底层,防火门自闭器损坏(门损坏、自闭器损坏缺陷常见) | 60 |
SINGAPORE | 07120 | SOLAS IMO Symbol for engine room emergency escape trunk door at lower platform was not available during inspection.逃生通道符号未张贴(客船要求张贴,货船不要求) | 17 |
GIBRALTAR | 07120 | E/R escape room trunk found with no lighting. (ISM)机舱应急逃生通道应急灯故障 | 17 |
英语建议信格式ROTTERDAM | 07120 | Emergency escape hatch E/G room was not able to be opened from inside. Beside that not all curing devices operational of that hatch. (ISM)机舱应急逃生通道盖门无法打开。 | 梦见生孩子10 |
SHANGHAI | 07120 | Fire door and door frame for escape enclosure space in engine room deformed and transmittance, not insulated to the A-60.机舱环围内防火门和门框变形、透光,没隔热至A60(门A60的问题要参考船舶建造年限,02年以前无要求) | 30 |
HUMEN | 07120 | One part internal dimensions of engine room escape way only 600mm x 600mm. (ISM)机舱应急逃生通道尺寸为600*600mm(同上一条缺陷,02.7.1之前机舱逃生通道无尺寸要求) | 30 |
GUANGZHOU | 07120 | Hand rail for the escape route nearby drying room and officer`s laundry & locker room in C deck not be provided.逃生通道没安装扶手(广州PSCO缺陷,同KR通告) | 17 |
AUGHINISH | 07120 | Escape route in board of E/R work shop found to be obstructed with ship's spare parts. (ISM)逃生通道被船舶备件阻挡 | 17 |
HAMBURG | 07120 | Emergency exit from vehicle deck to open deck blocked and not openable, neither from inside nor from outside. (ISM) | 30 |
HAMBURG | 07120 | The emergency ladders in the car decks can not get reached becau of the cars are stored clo to superstructure, not as requested in C.S.M. Min. 50 cm so not possible to pass by. (ISM)car deck通道被车堵住,不符合系固手册上50cm通道的要求 群友提的通道中是否可以装货物,同这个缺陷一样的道理,查看系固手册的要求。群友提问照片如下: | 30 |