Surface Mounting DPDT Relay
■Long terminals for ideal for soldering and mount-ing reliability.
■Space-saving inside-L terminal.
■
High dielectric strength between coil and contacts (2,000 VAC), and between contacts of different polarity (1,500 VAC).
■
狼站
High impul withstand voltages between coil and contacts, and between contacts of different polar-ity (2,500 V, 2 × 10 μs: Bellcore requirements).■Low power consumption (140 mW).
■Bifurcated crossbar contact (Au-clad) and Fully aled construction for high reliability.■Applicable to IRS.
■High alability after IRS.
■Ultra-miniature at 15 × 7.5 × 9.4 mm (L × W × H).■Through-hole terminal is available
■
EN60950/EN41003 Supplementary Insulation-certified type is available.Model Number Legend
1.Relay Function
狗为什么吃草None:Single-side stable U:Single-winding latching K:Double-winding latching 2.Contact Form 2:DPDT 3.Terminal Shape
None:PCB terminal G:Inside-L surface mounting terminal F:Outside-L surface mounting terminal
4.Approved Standards None:UL/CSA
Y:EN60950/EN410035.Rated Coil Voltage
3, 4.5, 5, 12, 24 VDC
RoHS Compliant
Classification
Single-side stable Single-winding latching Double-winding latching Single-side stable
EN60950/EN41003DPDT
Fully aled
PCB terminal G6S-2G6SU-2G6SK-2G6S-2-Y Surface mount-ing terminal
Inside-L G6S-2G G6SU-2G G6SK-2G
G6S-2G-Y Outside-L
G6S-2F
G6SU-2F
G6SK-2F
G6S-2F-Y
■
Single-side Stable Type (G6S-2, G6S-2F, G6S-2G)
形容幸福的词语Note:
1.The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.Operating characteristics are measured at a coil temperature of 23°C.
3.The maximum voltage is the highest voltage that can be impod on the relay coil.
Single-winding Latching Type (G6SU-2, G6SU-2F, G6SU-2G)
Note:
1.The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.Operating characteristics are measured at a coil temperature of 23°C.
3.The maximum voltage is the highest voltage that can be impod on the relay coil.
Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G)
Note:
1.The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.Operating characteristics are measured at a coil temperature of 23°C.
3.The maximum voltage is the highest voltage that can be impod on the relay coil.
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current 46.7 mA 31.0 mA 28.1 mA 11.7 mA 8.3 mA Coil resistance 64.3Ω
145 Ω
178Ω
1,028Ω
2,880 Ω
Must operate voltage 75% max. of rated voltage Must relea voltage 10% min. of rated voltage Max. voltage 200% of rated voltage at 23°C 170% of rated voltage at 23°C Power consumption Approx. 140 mW
Approx. 200 mW
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current 33.3 mA 22.2 mA 20 mA 8.3 mA 6.3 mA Coil resistance 90Ω203 Ω250Ω1,440Ω3,840 ΩCoil inductance (H) (ref. value)Armature OFF 0.1080.270.36 2.12 5.80Armature ON
0.069
0.14
外贸出口公司
0.18
1.14
3.79
Must t voltage 75% max. of rated voltage Must ret voltage 75% max. of rated voltage Max. voltage 180% of rated voltage at 23°C Power consumption Approx. 100 mW
Approx. 150 mW
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current 66.6 mA 44.4 mA 40 mA 16.7 mA 12.5 mA Coil resistance 45Ω101 Ω125Ω720Ω1,920 ΩCoil induc-tance (H) (ref. value)
Set Armature OFF 0.0450.120.140.60 1.98Armature ON 0.0350.0740.0880.41 1.23Ret
Armature OFF 0.0320.0820.0980.46 1.34Armature ON
0.045
0.14
0.16
0.54
2.23
Must t voltage 75% max. of rated voltage Must ret voltage 75% max. of rated voltage Max. voltage 170% of rated voltage at 23°C 140% of rated voltage at 23°C Power consumption Approx. 200 mW
Approx. 300 mW
Single-side Stable EN60950/EN41003 Approved Type (G6S-2-Y, G6S-2F-Y, G6S-2G-Y)
Note:
1.The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.Operating characteristics are measured at a coil temperature of 23°C.
3.The maximum voltage is the highest voltage that can be impod on the relay coil.
■
跳动的心Contact Ratings
Note:
P level: λ60 = 0.1 x 10-6/operation
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions.
■
Characteristics
Note:The above values are initial values.
Note:
1.The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2.Values in parenthes are actual values.蓝莓面包
3.The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as tho ud for checking the dielectric strength (except between the t and ret coil).
12月份
Rated voltage 5 VDC 12 VDC 24 VDC Rated current 40 mA 16.7 mA 9.6 mA Coil resistance 125Ω
720Ω
2,504Ω
Must operate voltage 75% max. of rated voltage Must relea voltage 10% min. of rated voltage Max. voltage 170% of rated voltage at 23°C 170% of rated voltage at 23°C
Power consumption Approx. 200 mW
Approx. 230 mW
Load Resistive load (cos φ = 1)Rated load 0.5 A at 125 VAC; 2 A at 30 VDC Contact material Ag (Au-Alloy)Rated carry current 2 A
Max. switching voltage 250 VAC, 220 VDC Max. switching current 2 A
Max. switching power 62.5 VA, 60 W Failure rate (reference value) (See note.)10μA at 10 mVDC
Contact resistance (See note 1.)75 m Ω max.
Operate (t) time (See note 2.) 4 ms max. (approx. 2.5 ms; latching type: approx. 2 ms)Relea (ret) time (See note 2.) 4 ms max. (approx. 1.5 ms; latching type: approx. 2 ms)Bounce time
Operate: Approx. 0.5 ms Relea: Approx. 0.5 ms Set/Ret: Approx. 0.5 ms
Max. operating frequency
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)Insulation resistance (See note 3.)1,000 M Ω min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between coil and contacts (double-winding latching)1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
500 VAC, 50/60 Hz for 1 min between t and ret coil (double-winding latching)Impul withstand voltage
2,500 V (2 x 10 μs) between coil and contacts
1,500 V (10 x 160 μs) between coil and contacts (double-winding latching)2,500 V (2 x 10 μs) between contacts of different polarity
1,500 V (10 x 160 μs) between contacts of same polarity (conforms to FCC Part 68)Vibration resistance Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude)Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)Shock resistance Destruction: 1,000 m/s 2 (approx. 100G)Malfunction: 750 m/s 2 (approx.
75G)
Endurance
Mechanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (2 A at 30 VDC, resistive load: 1,200 operations/hr)100,000 operations min. (0.5 A at 125 VAC, resistive load)
Ambient temperature Operating:−40°C to 85°C (with no icing), −40°C to 70°C (double-winding latching, 24 VDC)Ambient humidity Operating: 5% to 85%Weight Approx. 2 g
■
Approved Standards
UL1950 (File No. E41515)/CSA C22.2 No.950 (File No. LR31928)
EN60950/EN41003
Model
Contact form
Coil ratings
Contact ratings
G6S-2, G6S-2F, G6S-2G DPDT
1.5 to 48 VDC 2 A, 30 VDC 0.3 A, 110 VDC 0.5 A, 125 VAC
G6SU2, G6SK-2, G6SU-2F, G6SU2G, G6SK-2F, G6SK-2G
1.5 to 24 VDC
Model
Contact form
Isolation category Voltage
G6S-2-Y, G6S-2G-Y, G6S-2F-Y
DPDT
Supplementary Isolation
250 VAC
Double-winding Latching S w i t c h i n g c u r r e n t (A )
G6SU
G6SK 12 VDC max.
G6SK 24 VDC
AC resistive load
后置定语英语DC resistive load
12 VDC max.
24 VDC
(G6S-Y , 12 VDC max.)
G6SU
12 VDC max.
G6SU 24 VDC G6SK
12 VDC max.
G6SK 24 VDC
Ambient temperature (°C)
12 VDC max.
24 VDC (G6S-Y)
24 VDC
(G6S-Y , 12 VDC max.)
24 VDC (G6S-Y)(1) IRS Method (Mounting Solder: Lead)
Time (s)
Soldering Preheating
Soldering
Preheating 220 to 240180 to 200150
90 to 120
20 to 30