Corning® ClearCurve® Multimode Optical Fiber
Product Information
Bend Performance and Compatibility
Corning ® ClearCurve ® ultra-bendable lar–optimized™ multimode optical fiber delivers the best macrobending performance in the industry while maintaining compatibility with current optical fibers, equipment, practices and procedures. ClearCurve OM 2, OM 3 and OM 4 multimode fiber is designed to withstand tight bends and challenging cabling routes with substantially less signal loss than conventi
onal multimode fiber. This new multimode optical fiber allows designers, installers and operators of enterpri networks (including local area networks, data centers and industrial networks) to u multimode optical fiber in a package that is easier to handle and install. With greater signal protection when subjected to tight bending, ClearCurve offers greater system curity and reliability meaning maximized network up-time and lower associated maintenance costs.Building on the proven bandwidth capability of Corning’s InfiniCor ® fibers, the world’s first lar-optimized™ multimode fibers, ClearCurve multimode fibers increa your capacity to succeed:
• Industry leading macrobending performance below 10 mm radius
• High performance minEMBc certified bandwidth to support 850 nm transmission at data rates up to 100 Gb/s
• Higher data aggregation in the backbone, rir and high-speed parallel interconnects (HSPIs)• Fully backwards-compatible and ideally suited to current and future broad range of lar-bad protocols and applications
• Superior measurement technology and manufacturing control
• Industry-leading CPC ® coatings for superior microbend and environmental performance
PI1468 | ISSUED: JANUARY 2011 | SUPERSEDES: DECEMBER 2010 | TL9000/ISO 9001 REGISTERED
ClearCurve ® OM 4 fiber
ClearCurve ® OM 3 fiber ClearCurve ® OM 2 fiber Optimized Data Rate over Distance 40/100 Gb/s over 170 m*10 Gb/s over 550 m 1 Gb/s over 1100 m
40/100 Gb/s over 140 m* 10 Gb/s over 300 m 1 Gb/s over 1000 m
Not included in the standard 10 Gb/s over 150 m 1 Gb/s over 750 m
Standards Compliance ISO/IEC 11801type OM 4 fiber type OM 3 fiber type OM 2 fiber IEC 60793-2-10type A 1a.3 fiber type A 1a.2 fiber type A 1a.1 fiber TIA/EIA 492AAAD 492AAAC-B 492AAAB-A ITU
ITU G 651.1
ITU G 651.1爱在心底口难开
ITU G 651.1
* D istances specified in the 40G/100G per IEEE 802.3ba standard are 150m on OM 4 and 100m on OM 3; Corning fibers are manufactured
to tighter dispersion specifications and thereby support the extended distances shown in the table (assuming cable attenuation ≤3.0 dB/km and same 1.0 dB of connector loss for OM 3 that the standard requires for OM 4).
The Smart, Reliable, Cost-Effective Network Choice
No one can match Corning’s superior measurement technology and manufacturing control of the refractive index profile. Conquently, ClearCurve multimode optical fibers deliver exceptional high bandwidth and superior transmission performance for the most demanding applications, while allowing the u of low-cost, high-speed 850 nm vertical cavity surface-emitting lars (VCSELs).
High Bandwidth Performance You Can Rely On
Corning is a world leader in developing and using the most advanced measurement techniques for lar-optimized multimode fibers. Corning us direct manufacturing process control and integrated measurement techniques for all ClearCurve fibers to ensure robust performance in lar-bad systems.
和风细雨造句
We ensure EMB via calculated effective modal bandwidth (minEMBc) for all our ClearCurve multimode optical fibers. minEMBc is a differential mode delay (DMD) - 100% measured bandwidth method that best predicts multimode performance in high-bandwidth lar-bad systems up to and including 100 Gb/s. Corning was the first optical fiber manufacture to provide customers with minEMBc measured bandwidth values for individual lar-optimized multimode fibers.
Optical Specifications
Numerical Aperture 0.200 ± 0.015
Mandrel Number of Induced Attenuation (dB)Radius (mm)
Turns
850 nm 1300 nm 37.5100≤ 0.05≤ 0.15152≤ 0.1≤ 0.37.5
2
≤ 0.2
≤ 0.5
Macrobend Loss
Wavelength (nm)
Maximum Value (dB/km)
850≤ 2.31300
≤ 0.6
No point discontinuity greater than 0.2 dB. Attenuation at 1380 nm does
not exceed the attenuation at 1300 nm by more than 3.0 dB/km.
Attenuation
High Performance EMB*
(MHz.km)
Legacy Performance EMB**
(MHz.km)Corning Optical Fiber 850 nm only
850 nm 1300 nm ClearCurve ® OM 4 fiber 47003500500ClearCurve ® OM 3 fiber 20001500500ClearCurve ® OM 2 fiber
950
700
500
*Ensured via minEMBc, per TIA/EIA 455-220A and IEC 60793-1-49, for high performance lar-bad systems (up to 100 Gb/s).**OFL BW, per TIA/EIA 455-204 and IEC 60793-1-41, for legacy and LED-bad systems (typically up to 100 Mb/s).
Bandwidth
Coating Diameter
242 ± 5 μm Coating-Cladding Concentricity
书香校园标语
< 12 μm
Coating Geometry
后台应用
Core Diameter 50.0 ± 2.5 μm Cladding Diameter 125.0 ± 1.0 μm Core-Clad Concentricity ≤ 1.5 μm Cladding Non-Circularity ≤ 1.0%Core Non-Circularity
≤ 5%
Glass Geometry
Dimensional Specifications
Environmental Test
Test Condition Induced Attenuation 850 nm
& 1300 nm (dB/km)
Temperature Dependence -60°C to +85°C
≤ 0.10Temperature Humidity Cycling -10°C to +85°C and 4% to 98% RH
≤ 0.10Water Immersion 23°C ± 2°C ≤ 0.20Heat Aging 85°C ± 2°C ≤ 0.20Damp Heat
85°C at 85% RH
≤ 0.20
Operating Temperature Range: -60°C to + 85°C
Environmental
Mechanical Specifications
Proof Test
The entire fiber length is subjected to a tensile stress ≥ 100 kpsi (0.7 GN/m 2)*.
* Higher proof test levels available.
Length
Fiber lengths available up to 17.6 km/spool.
Performance Characterizations
Characterized parameters are typical values.System Link Length
* OM 2 is not included in the IEEE 802.3ba Standard for 40/100 Gb/s systems.
** L ink lengths as characterized in IEEE 802.ae (10 Gigabit Ethernet) and IEEE 802.3ba (40 and 100 Gigabit
Ethernet) for ClearCurve multimode fiber-specific bandwidth metrics and standards compliant components.*** 40 Gb/s and 100 Gb/s link lengths shown for ClearCurve OM 3 and ClearCurve OM 4 fiber systems require cable attenuation ≤ 3.0 dB/km and total connector loss ≤ 1.0 dB.† OM 4 requires 1.0 dB of connector loss.†† OM 3 allows for 1.0 dB of connector loss.
冉姓10 Gb/s Link Lengths @ 850 nm Bad on IEEE 802.3ae
若字开头的成语
A dditional system reach capable with ClearCurve OM 2/OM 3/OM 4 fiber reel-specific bandwidth metric and values as provided by Corning (subject to availability)
10 Gb/s link length show for ClearCurve OM 4 fiber require cable attenuation ≤ 3.0
dB/km and total
connector loss ≤ 1.0 dB.
#*40/100 Gb/s Link Lengths @ 850 nm Bad on IEEE 802.3ba
A dditional system reach capable with ClearCurve OM 3/OM 4 fiber reel-specific bandwidth metric and values as provided by Corning (subject to availability).
#
新鲜罗汉果Refractive Index Difference 1%
Effective Group Index of Refraction (N eff ) 850 nm: 1.480 1300 nm: 1.479N eff was empirically derived to the third decimal place using a specific commercially available OTDR
Fatigue Resistance Parameter (n d ) 20
Coating Strip Force
Dry: 0.6 lbs (2.7N)
Wet, 14 days in 23ºC water soak: 0.6 lbs (2.7N)
Chromatic Dispersion
Zero Dispersion Wavelength (λ0): 1295 nm ≤ λ0 ≤ 1315 nm Zero Dispersion Slope (S 0): ≤ 0.101 ps/(nm 2·km )Corning Incorporated One Riverfront Plaza Corning, NY 14831 U.S.A.Ph: 607-248-2000
Email:
Corning and ClearCurve are registered trademarks of Corning Incorporated, Corning, NY.
© 2011 Corning Incorporated
Spectral Attenuation (Typical Fiber)
Wavelength (nm)
A t t e n u a t i o n (d
B /k m )
800
1000
亲爱的女孩
12001400
1600
0.00.51.01.52.02.53.0