MaterialResistivityReferenceNotes IACS Siemens/m Ohm-m See End NoteCopper and Copper Alloys by Copper Alloy Number Pure annealed
100.005.800E071.724E-08ECTMC10100
C10200101.001.710E-08MHASM2C10300-O6199.001.740E-08MHASM2C10400
C10500 C10700 O61
temper100.001.720E-08MHASM2C10800-O6192.001.870E-08MHASM2C11000-O601 00-101.51.700E-8--1.724E-8MHASM2C11000-H1497.001.780E-08MHASM2C111001 00.001.720E-08MHASM2C11300 C11400 C11500
C11600100.001.720E-08MHASM2C12500 C12700 C12800 C12900 C13000 annealed98.001.760E-08MHASM2C1430096.001.800E-08MHASM2C1431085.002.030 E-08MHASM2C1450093.001.860E-08MHASM2C14700-O6195.001.810E-08MHASM 2C1500093.001.860E-08MHASM2C15100 annealed95.001.810E-08MHASM2C15100 rolled90.001.920E-08MHASM2C15500
annealed91.001.900E-08MHASM2C1571090.001.920E-08MHASM2C1572089.001.940 E-08MHASM2C1620090.001.920E-08MHASM2C17000-TB00
strip28-335.2E-8--6.2E-8MHASM2resistivity converted from conductivityC17000-TB00 rod bar plate tubing forgings17-199.1E-8--1.0E-7MHASM2resistivity converted from conductivityC17000-TB00 billet13-189.6E-8--1.3E-7MHASM2resistivity converted from conductivityC17000-TD01 strip29-345.0E-8--5.9E-8MHASM2resistivity converted from conductivityC17000-TD02 strip32-384.5E-8--5.4E-8MHASM2resistivity converted from conductivityC17000-TD04 strip35-394.4E-8--4.9E-8MHASM2resistivity converted from conductivityC17000-TD04 rod bar plate
tubing15-171.0E-7--1.1E-7MHASM2resistivity converted from
conductivityC17000-TF00 strip35-394.8E-8--4.8E-8MHASM2resistivity converted from conductivityC17000-TF00 rod bar plate tubing
forgings22-256.9E-8--7.8E-8MHASM2resistivity converted from
conductivityC17000-TF00 billet18-256.9E-8--9.6E-8MHASM2resistivity converted from conductivityC17000-TH01 strip36-414.1E-8--4.8E-8MHASM2resistivity converted from conductivityC17000-TH02 strip36-423.8E-8--4.5E-8MHASM2resistivity converted from conductivityC17000-TH04 strip38-454.7E-8--5.2E-8MHASM2resistivity converted from conductivityC17000-TH04 rod bar plate tubing22-256.9E-8--7.8E-8MHASM2resistivity converted fro
m conductivityC17000-TM00
strip33-374.5E-8--5.1E-8MHASM2resistivity converted from
conductivityC17000-TM01 strip34-384.4E-8--4.9E-8MHASM2resistivity converted from conductivityC17000-TM02 strip35-394.3E-8--4.8E-8MHASM2resistivity converted from conductivityC17000-TM04
strip36-404.1E-8--4.7E-8MHASM2resistivity converted from
conductivityC17000-TM06 strip37-424.1E-8--4.7E-8MHASM2resistivity converted from conductivityC17000-TM08 strip33-453.8E-8--5.2E-8MHASM2resistivity converted from conductivityC17000 as-cast
billet16-227.8E-8--1.1E-7MHASM2resistivity converted from conductivityConductivityConductivity and Resistivity Values for Copper AlloysCompiled by the Collaboration for NDT EducationC17000 cast and aged
billet18-237.5E-8--9.6E-8MHASM2resistivity converted from conductivityC17200
C17300-TB0017-199.1E-8--1.0E-7MHASM2resistivity converted from conductivityC17200 C17300-TB00 billets25-453.8E-8--6.9E-8MHASM2resistivity
converted from conductivityC17200
C17300-TD0116-189.6E-8--1.1E-7MHASM2resistivity converted from conductivityC17200 C17300-TD0215-171.0E-7--1.1E-7MHASM2resistivity converted from conductivityC17200 C17300-TD0415-171.0E-7--1.1E-7MHASM2resistivity converted from conductivityC17200
C17300-TF0022-256.9E-8--7.8E-8MHASM2resistivity converted from conductivityC17200 C17300-TF00 billets1.0-3.05.7E-7--1.7E-6MHASM2resistivity converted from conductivityC17200
C17300-TH0122-256.9E-8--7.8E-8MHASM2resistivity converted from conductivityC17200 C17300-TH0222-256.9E-8--7.8E-8MHASM2resistivity converted from conductivityC17200 C17300-TH0422-256.9E-8--7.8E-8MHASM2resistivity converted from conductivityC17200
C17300-TM0020-286.2E-8--8.6E-8MHASM2resistivity converted from conductivityC17200 C17300-TM0120-286.2E-8--8.6E-9MHASM2resistivity converted from conductivityC17200 C17300-TM0220-286.2E-8--8.6E-10MHASM2resistivity converted from conductivityC17200
C17300-TM0420-286.2E-8--8.6E-11MHASM2resistivity converted from conductivityC17200 C17300-TM0620-286.2E-8--8.6E-12MHASM2resistivity converted from conductivityC17200 C17300-TM0820-286.2E-8--8.6E-13MHASM2resistivity converted from conductivityC17200 C17300 as-cast
billet15-305.7E-8--1.1E-7MHASM2resistivity converted from conductivityC17200
C17300 cast and aged billet10.0-208.6E-8--1.7E-7MHASM2resistivity converted from conductivityC1741045.003.800E-08MHASM2C17500-TB0020-305.7E-8--8.6E-8MHAS M2resistivity converted from
conductivityC17500-H0420-305.7E-8--8.6E-9MHASM2resistivity converted from conductivityC17500-TF0045-602.9E-8--3.8E-8MHASM2resistivity converted from conductivityC17500-TH0450-602.9E-8--3.4E-8MHASM2resistivity converted from conductivityC17500-HTR45-602.9E-8--3.8E-8MHASM2resistivity converted from conductivityC17500-HTC60 min2.9E-8 maxMHASM2resistivity converted from conductivityCompiled by the Collaboration for NDT
EducationC17600-TB0020-305.7E-8--8.6E-9MHASM2resistivity converted from conductivityC17600-TB00 billet22-286.2E-8--7.8E-8MHASM2resistivity converted from conductivityC17600-H0420-305.7
E-8--8.6E-9MHASM2resistivity converted from conductivityC17600-TF0045-602.9E-8--3.8E-8MHASM2resistivity converted from conductivityC17600-TF00 billet forged
products50-602.9E-8--3.4E-8MHASM2resistivity converted from
conductivityC17600-TH0450-602.9E-8--3.4E-8MHASM2resistivity converted from conductivityC17600 as-cast billet32-374.7E-8--5.4E-8MHASM2resistivity converted from conductivityC17600 cast and aged billet40-503.4E-8--4.3E-8MHASM2resistivity converted from conductivityC18100 annealed80.002.170E-08MHASM2C18200 C18400 C18500-TB0040.004.310E-08MHASM2resistivity converted from conductivityC18200 C18400
C18500-TH0480.002.163E-08MHASM2C1870096.007.790E-08MHASM2C19200 strip60.002.880E-08MHASM2C19200
tubing50.003.450E-08MHASM2C1921080.002.160E-08MHASM2C19400-O6040.004.3 10E-08MHASM2C19400-H1450.003.450E-08MHASM2C19400 all other tempers65
nominal2.26e-8
nominalMHASM2C1950050.003.440E-08MHASM2C1952040.004.930E-08MHASM2 C1970080.002.
160E-08MHASM2C21000 annealed56.003.100E-08MHASM2C22000 annealed44.003.910E-08MHASM2C22600 annealed40.004.300E-08MHASM2C23000 annealed37.004.700E-08MHASM2C24000-O61
32.005.400E-08MHASM2C26000-O6128.006.200E-08MHASM2C26800 C27000 annealed27.006.400E-08MHASM2C2800028.006.160E-08MHASM2C3140042.004.100 E-08MHASM2C3160032.005.400E-08MHASM2C3300026.006.600E-08MHASM2C33 200-O6126.006.600E-08MHASM2C3350026.006.600E-08MHASM2C34000-O6126.00 6.600E-08MHASM2C34200
C35300-O6126.006.600E-08MHASM2C3490026.006.600E-08MHASM2C3500026.006. 600E-08MHASM2C35600-O6126.006.600E-08MHASM2C36000-O6126.006.600E-08 MHASM2C36500 C36600 C36700
C36800-O6128.006.200E-08MHASM2C37000-O6127.006.390E-08MHASM2C377002 7.006.400E-08MHASM2C38500-O6128.006.200E-08MHASM2Compiled by the Collaboration for NDT
EducationC3604C3602C4050041.004.200E-08MHASM2C4080037.004.660E-08MHAS M2C4110032.005.400E-08MHASM2C4150028.006.200E-08MHASM2C4190022.007.8 00E-08MHA
SM2C4220031.005.500E-08MHASM2C4250028.006.200E-08MHASM2C 4300027.006.400E-08MHASM2C4340031.005.600E-08MHASM2C4350028.006.200E-08MHASM2C44300 C44400 C4450025.006.900E-08MHASM2C46400 C45600
C46600 C46700
annealed26.006.630E-08MHASM2C4820026.006.630E-08MHASM2C4850026.006.630 E-08MHASM2C5050048.003.600E-08MHASM2C5071030.005.740E-08MHASM2C51 00020.008.700E-08MHASM2C5110020.008.700E-08MHASM2C5210013.001.330E-07 MHASM2C5240011.001.570E-07MHASM2C5440019.009.100E-08MHASM2C606001 7.001.000E-07MHASM2C6080017.001.000E-07MHASM2C6100015.001.150E-08MH ASM2C6130012.001.440E-07MHASM2C6140014.001.230E-07MHASM2C6150012.60 1.370E-07MHASM2C6230012.001.440E-07MHASM2C6240012.001.440E-07MHASM 2C6250010.001.720E-07MHASM2C630009.001.920E-06MHASM2C632007.002.460E-08MHASM2C6360012.001.430E-07MHASM2C63800
10.001.740E-07MHASM2C6510012.001.440E-07MHASM2C654007.002.460E-07MH ASM2C655007.002.460E-07MHASM2C66400-O6130.005.750E-08MHASM2C68800-O6118.009.60
0E-08MHASM2C68800-H0816.601.040E-07MHASM2C69000-O6118.00 9.600E-08MHASM2C694006.202.800E-07MHASM2C7025035-404.31E-8--4.93E-8M HASM2C7040014.001.200E-07MHASM2C706009.101.900E-07MHASM2C71000-O61 6.502.650E-07MHASM2C71500-O614.603.750E-07MHASM2C719004.403.950E-07M HASM2C722006.532.640E-07MHASM2C7250011.001.570E-07MHASM2C745009.00 1.920E-07MHASM2C752006.002.870E-07MHASM2C754007.002.460E-07MHASM2C 757008.002.160E-07MHASM2C770005.503.140E-07MHASM2Compiled by the Collaboration for NDT
EducationC7820010.901.600E-07MHASM2C8110092.001.874E-08MHASM2resistivity converted from conductivityC8130060.002.874E-08MHASM2resistivity converted from conductivityC81500 solution heat treated40-503.830E-08MHASM2C81500 precipitation hardened80-902.100E-08MHASM2C8180048.003.590E-08MHASM2C8200048.003.59 0E-08MHASM2C8220048.003.590E-08MHASM2C8240025.006.900E-08MHASM2C8
250020.008.620E-08MHASM2C8260019.009.070E-08MHASM2C8280018.009.580E-0 8MHASM2C8330032.005.388E-08MHASM2resistivity converted from conductivityC8360015.001.149E-07MHASM2resistivity converted from conductivityC8380015.001.149E-07MHASM2resistivity converted from conductivityC8440016.401.0
51E-07MHASM2resistivity converted from conductivityC8480016.401.051E-07MHASM2resistivity converted from conductivityC8520018.609.269E-08MHASM2resistivity converted from conductivityC8540019.608.796E-08MHASM2resistivity converted from conductivityC85700 C8580022.007.837E-08MHASM2resistivity converted from conductivityC86100 C862007.502.299E-07MHASM2resistivity converted from conductivityC863009.001.916E-07MHASM2resistivity converted from conductivityC8640022.007.837E-08MHASM2resistivity converted from conductivityC8650020.508.410E-08MHASM2resistivity converted from conductivityC8670032.005.388E-08MHASM2resistivity converted from conductivityC868009.001.916E-07MHASM2resistivity converted from conductivityC87300 formerly C872006.702.573E-07MHASM2resistivity converted from conductivityC876006.002.874E-07MHASM2resistivity converted from conductivityC87500
C878006.702.840E-07MHASM2C8790015.001.149E-07MHASM2resistivity converted from conductivityCompiled by the Collaboration for NDT
EducationC9030012.001.437E-07MHASM2resistivity converted from
conductivityC9050011.001.567E-07MHASM2resistivity converted from conductivityC907009.601.50
0E-08MHASM2C9170010.001.724E-07MHASM2resistivit y converted from
conductivityC9220014.301.200E-07MHASM2C9230012.001.437E-07MHASM2resistivi ty converted from conductivityC926009.001.916E-07MHASM2resistivity converted from conductivityC9270011.001.567E-07MHASM2resistivity converted from conductivityC929009.201.874E-07MHASM2resistivity converted from conductivityC9320012.001.437E-07MHASM2resistivity converted from conductivityC9340012.001.437E-07MHASM2resistivity converted from conductivityC9350015.001.149E-07MHASM2resistivity converted from conductivityC9370010.141.700E-07MHASM2conductivity converted from resistivityC9380011.501.499E-07MHASM2resistivity converted from
conductivityC9390011.501.499E-07MHASM2resistivity converted from conductivityC943009.001.916E-07MHASM2resistivity converted from conductivityC9450010.001.724E-07MHASM2resistivity converted from conductivityC9520012.001.440E-07MHASM2C9530013.001.330E-07MHASM2C95400 13.001.330E-07MHASM2C955008.502.030E-07MHASM2C956008.502.028E-07MHA SM2resistivity converted from
conductivityC957003.105.560E-07MHASM2C958007.102.430E-07MHASM2C9620011 .001.567E-07MHASM2resistivity converted from
conductivityC964005.003.448E-07MHASM2resistivity converted from conductivityC966004.304.000E-09MHASM2C97300
as-cast5.703.025E-07MHASM2resistivity converted from conductivityC97600
as-cast5.003.448E-07MHASM2resistivity converted from conductivityC97800
as-cast4.503.831E-07MHASM2resistivity converted from
conductivityC99400-TF0016.801.026E-07MHASM2resistivity converted from conductivityC9950013.701.258E-07MHASM2resistivity converted from conductivityC997003.005.747E-07MHASM2resistivity converted from conductivityC997502.008.621E-07MHASM2resistivity converted from conductivityDeoxidized Annealed85.004.930E072.028E-08CSNDTElectrolytic Tough Pitch Annealed101.005.858E071.707E-08CSNDTCopper 70 Nickel
304.502.610E063.831E-07ECTMCopper 90 Nickel
109.745.647E061.771E-07ECTCupro - Nickel
304.602.668E063.748E-07CSNDTCompiled by the Collaboration for NDT EducationBeryllium CopperBeryllium Copper Cond.
A17.009.860E061.014E-07CSNDTBeryllium Copper Cond.
At21.001.218E078.210E-08CSNDTBeryllium Copper
21C20.008.620E-04MHASM2Beryllium Copper Nickel
72C43.004.000E-03MHASM2BrassAdmiralty
Brass24.001.392E077.184E-08ECTMAdmiralty Metal
Annealed24.601.427E077.009E-08CSNDTAluminum Brass
Annealed23.001.334E077.496E-08CSNDTCartridge
Annealed28.001.624E076.158E-08CSNDTHigh Strength
Yellow12.006.960E061.437E-07CSNDTLeaded Naval
Annealed26.001.508E076.631E-08CSNDTLeaded Semi
Red18.001.044E079.579E-08CSNDTLeaded
Yellow25.001.450E076.897E-08CSNDTLow
Annealed32.001.856E075.388E-08CSNDTLow Leaded
Annealed26.001.508E076.631E-08CSNDTNaval
Annealed26.001.508E076.631E-08CSNDTRed
Annealed37.002.146E074.660E-08CSNDTYellow
Annealed27.001.566E076.386E-08CSNDTAluminum Brass
Annealed23.001.334E077.496E-08CSNDTBronzeCommercial
Annealed44.002.552E073.918E-08CSNDTCommercial
Leaded42.002.436E074.105E-08CSNDTLeaded
Tin14.008.120E061.232E-07CSNDTLeaded Tin
Bearing11.006.380E061.567E-07CSNDTMangane Bronze
Annealed24.001.392E077.184E-08CSNDT1.25 Phos. Grade
E48.002.784E073.592E-08CSNDT5 Phos. Grade A18.001.044E079.579E-08CSNDT8 Phos. Grade C13.007.540E061.326E-07CSNDT10 Phos. Grade
D11.006.380E061.567E-07CSNDTAluminum BronzeAluminum -
Bronze14.008.120E061.232E-07CSNDT5 Aluminum
Annealed17.501.015E079.852E-08CSNDT10 Aluminum
Annealed12.607.308E061.368E-07CSNDTSilicon BronzeSilicon Bronze Type A Annealed7.004.060E062.463E-07CSNDTSilicon Bronze Type B
Annealed12.006.960E061.437E-07CSNDTCSNDTCSNDT compiled by Eddy Current Technology IncorporatedECTEddy Current Technology IncorporatedECTMEddy Current Testing Manual on Eddy
Current Method compiled by Eddy Current Technology IncorporatedMHASM2ASM Metals Handbook--Volume 2 Tenth EditionCompiled by the Collaboration for NDT Education