基于参考应力法的海底腐蚀管道剩余强度评价

更新时间:2023-05-05 11:36:56 阅读: 评论:0

基于参考应力法的海底腐蚀管道剩余强度评价
黄坤;李沅桦;孔令圳
【摘 要】在役海底管道所处海洋环境恶劣,管道发生腐蚀后剩余强度降低.为了更加准确地计算管道的剩余强度,基于ANSYS非线性有限元模拟,采用参考应力法,研究了参考应力分别为(SMYS+ SMTS)/2,1.1SMYS,SMYS+ 69,0.8SMTS,0.9SMTS,SMTS的海底管道剩余强度,将结果与爆破实验数据作对比,提出了参考应力和流变应力取值的推荐算法.研究结果表明,在海底腐蚀管道剩余强度有限元分析中,对于X46,X60和X80管道,建议分别使用(SMYS+SMTS)/2,0.9SMTS和SMTS作为参考应力;推荐使用(SMYS+ SMTS)/2,SMYS+ 69和1.1SMYS三者中的最大值作为流变应力.%The in-rvice submarine pipeline is in the vere marine environment,so the residual strength of the pipeline decreas after corrosion.In order to calculate the residual strength of the pipeline more accurately,bad on the ANSYS nonlinear finite element simulation,the residual strength of submarine pipeline with the reference stress as (SMYS + SMTS) / 2,1.1SMYS,SMYS + 69,0.8SMTS,0.9SMTS and SMTS respectively were studied by using the reference stress method.The results were co
mpared with the data from blasting experiment,and the recommended algorithm for the valuing of reference stress and flow stress was put forward.The results showed that in the finite element analysis on the residual strength of submarine corrosion pipeline,the suggested reference stress for X46,X60 and X80 pipeline was (SMYS + SMTS)/2,0.9 SMTS and SMTS respectively.It was recommended that the maximum value of (SMYS + SMTS)/2,SMYS + 69 and 1.1 SMYS should be taken as the flow stress in the calculation.
【期刊名称】《中国安全生产科学技术》
【年(卷),期】2017(013)007
【总页数】5页(P163-167)
【关键词】海底管道;腐蚀;剩余强度;参考应力
【作 者】黄坤;李沅桦;孔令圳
【作者单位】西南石油大学石油与天然气工程学院,四川成都610500;西南石油大学石油与天然气工程学院,四川成都610500;西南石油大学石油与天然气工程学院,四川成都610500
【正文语种】中 文
【中图分类】X937
0 引言
海底管道环境载荷复杂,易受到腐蚀,腐蚀失效是海底管道失效的主要形式,所占比例高达35%[1-2]。因此,进行海底管道剩余强度评价对于海底管道的维修、更换、降低压力等决策具有重要的现实意义。国内外许多专家对含缺陷管道做了很多研究,20世纪90年代中期,Fu等采用非线性有限元分析了腐蚀的深度、长度和宽度对管道破坏机理和极限内压荷载的影响,证明了基于应力失效准则的非线性有限元分析预测得到的腐蚀管道极限内压荷载具有很高的准确性;M. G.Kirkwood提出了1个失效准则,即屈服强化阶段结束时,或者管子的最小Mis应力达到极限抗拉强度(SMTS)时,管子发生塑性失效,否则是安全的。
结构的极限承载力是指结构完全崩溃前所能承受外荷载的最大能力,极限载荷的确定方法主要有0.2%残余应变准则、2倍弹性斜率准则、2倍弹性变形法、参考应力法等。其中,参考应力法认为,不管外加载荷的形式如何复杂,结构破坏的本质都是危险截面上的等效应
力达到材料的参考应力。但是不同的准则提出了不同的参考应力,弹性极限准则认为管材的屈服强度为参考应力。塑性失效准则认为极限抗拉强度为参考应力,不同的学者对参考应力也有不同的定义,有的学者建议流变应力为参考应力,Fu等建议采用SMTS作为参考应力;Choi建议采用0.9SMTS作为参考应力[3-5]。因此,以下运用ANSYS有限元模拟,分析了参考应力分别为(SMYS+SMTS)/2,1.1SMYS,SMYS+69,0.8SMTS,0.9SMTS,SMTS的管道剩余强度[6-9],将结果与爆破实验数据作对比,得出管材的适宜参考应力。适宜参考应力能够更加准确的计算管道剩余强度,具有一定的实用价值。
1 失效准则
常用的失效准则包括应力失效准则、应变失效准则、数值失稳准则。本文采用应力失效准则,即认为腐蚀区域的应力状态达到参考应力时,管道发生失效。Von Mis表达式为[10-11]:
(1)
式中:σ为参考应力;σ1,σ2,σ3分别是x,y,z方向的主应力,MPa。
2 本构模型
由Ramberg和Osgood提出的应力-应变方程,是固体力学中描述弹塑性材料应力—应变关系的1个经典理论模型,因此常被用来对实验曲线进行修正,该模型
的准确性己得到相关试验和有限元分析的证实,是目前可供选择的最佳本构模型。Ramberg-Osgood本构方程可以对在屈服应变4%以内的实际管材的应力-应变曲线进行很好的模拟,因此选用Ramberg-Osgood本构模型来描述抗大变形钢管道的实际本构关系。Ramberg-Osgood本构方程视总应变为弹性应变和塑性应变之和,其数学表达式为:
(2)
(3)
(4)
式中:ε为实际总应变,无量纲;E0为材料初始弹性模型,MPa;σ为应力,MPa;σR为Ramber-Osgood应力,MPa;n为材料的硬化系数。
3 爆破试验数据
共收集了16组爆破试验数据,如表1,模拟了5种失效应力状态下对应的失效内压。
表1 管道爆破实验数据Table 1 Pipeline blasting experiment data编号钢级屈服强度SMYS/MPa拉伸强度SMTS/MPa外径/mm壁厚/mm缺陷深度/mm缺陷长度/mm试验爆破压力/MPa12345X46317.2469.29323.348.462.1663.524.37323.098.592.97203.223.11323.098.642.6960.9625.2863.69.473185.4210.56863.69.374.6291.449.17678910X60452542323.99.87.08255.614.4323.99.666.76305.614.07323.99.726.9335013.58323.99.726.91394.512.84323.99.917.31433.412.13111213141516X80641740121919.8915.41605.727.6121919.897.44605.7217.7121919.891.77607.7423.3121913.7910.78588.374.7121913.795.45589.412121913.791.54586.4216.1
4 实例分析
4.1 有限元求解
4.1.1 单元类型的选择和边界条件的设定
以表1中编号6的管道为例,采用非线性分析[12],选择SOLID95网格划分。
4.1.2 加载求解计算
模拟的是管道两端密封的爆破实验,为了消除边界效应,根据圣维南原理,有限元模型的长度取管道直径的3倍,管段不存在轴向位移[13]。同时为计算收敛,直接在管道的一端取固定支撑,在管道对称面取对称支撑。管道爆破时受到的是均布内压。缺陷形状为矩形[14],模型网格的划分如图1,腐蚀区域局部网格划分如图2,应力云图如图3。
图1 模型网格划分Fig.1 Mesh model
图2 局部网格划分Fig.2 Local grid partition
图3 编号6的管道应力云图Fig.3 VonMis stress of No.6 pipeline
4.2 有限元的计算结果与分析
表2为X46管道在不同的参考应力下失效应力的有限元计算结果与爆破实验数据的对比。通过表2可以看出,X46管道的最佳参考应力为(SMYS+SMTS)/2,其次为SMYS+69。当使用0.9SMTS,SMTS作为参考应力时,有限元的计算结果超过了爆破压力,因此,不建议低强度钢材的参考应力使用SMTS。
表2 在6种参考应力下X46管道的失效应力与爆破实验数据对比Table 2 X46 in 6 kinds of reference under the stress offailure stress compared with blasting experiment data MPa编号(SMYS+SMTS)/2SMYS+691.1×SMYS0.8×SMTS0.9×SMTSSMTS爆破压力124.3123.922.0223.1224.4225.224.37223.222.521.922.223.5723.7923.11325.1424.923.9824.2125.6425.8325.2410.6110.219.5610.1310.7311.0210.5659.048.898.238.819.199.539.17
表3为不同的参考应力下X60管道失效应力的有限元计算结果与爆破实验数据的对比。通过表3可以看出,X60管道的最佳参考应力为0.9SMTS,其次为(SMYS+SMTS)/2和1.1SMYS,在这里(SMYS+SMTS)/2值为497MPa,1.1SMYS值为497.2MPa。而使用SMTS模拟得到的失效压力超过了实验的爆破压力。因此,推荐X60管道使用0.9SMTS作为参考应力。
表3 X60在6种参考应力下的失效应力与爆破实验数据对比Table 3 X60 in 6 kinds of reference under the stress offailure stress compared with blasting experiment data MPa编号(SMYS+SMTS)/2SMYS+691.1×SMYS0.8×SMTS0.9×SMTSSMTS爆破压力114.715.114.7012.7614.3315.3214.4214.1314.7314.1312.2314.0215.0314.07313.6214.2313.6211.8513.3314.8113.58413.4714.1213.4711.7612.7314.6912.84512.9313.5512.9311.2812.0914.1012.13
表4为不同参考应力下X80管道的失效应力有限元计算结果与爆破实验数据对比,通过表4可以看出,X80管道的最佳参考应力值为SMTS,其次为SMYS+69。因此,建议中高强度管材的参考应力选择SMTS。
表4 X80在6种参考应力下的失效应力与爆破实验数据对比Table 4 X80 in 6 kinds of reference under the stress offailure stress compared with blasting experiment data MPa编号(SMYS+SMTS)/2SMYS+691.1SMYS0.8SMTS0.9SMTSSMTS爆破压力15.615.875.804.265.496.737.6216.8417.2916.4214.3316.6318.4017.7
322.6423.0623.1919.9022.4623.4023.343.083.292.792.072.974.174.7510.8811.1711.099.4010.7512.1012

本文发布于:2023-05-05 11:36:56,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/89/857568.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:应力   管道   参考   爆破
相关文章
留言与评论(共有 0 条评论)
   
验证码:
推荐文章
排行榜
Copyright ©2019-2022 Comsenz Inc.Powered by © 专利检索| 网站地图