China Toll-Free: 800 999 1338
TEST REPORT
NUMBER: SHAH00282680
PREPARED AND CHECKED BY: AUTHORIZED BY: FOR INTERTEK TESTING SERVICES FOR INTERTEK TESTING SERVICES LTD., SHANGHAI LTD., SHANGHAI
MYRA LV STEPHEN TSANG CHEMICAL LAB SENIOR MANAGER GENERAL MANAGER
APPLICANT: TAIXING JINJI DYESTUFF CO., LTD. DATE: OCT 13, 2011 NO.10 XINGANG ROAD, ECONOMICAL & DEVELOPMENT ZONE, TAIXING, JIANGSU, CHINA.
ATTN: HUANG HONG YING
SAMPLE DESCRIPTION:
ELEVEN(11)SUBMITTED SAMPLES SAID TO BE :
(1)BLACK POWDER(REACTIVE BLACK 5 (REACTIVE BLACK KN-B));
(2)BLACK POWDER(REACTIVE BLUE 21 (REACTIVE TURQ. BLUE GX 、REACTIVE TUEQ. BLUE KN-G));
(3)BLACK POWDER(REACTIVE CADET BLUE G(REACTIVE NAVVY BLUE G 、REACTIVE BLUE 250))
(4)RED POWDER(REACTIVE RED 195(REACTIVE RED 3BS));
(5)BLACK POWDER(REACTIVE YELLOW 145(REACTIVE YELLOW 3RS ));
(6)YELLOW POWDER(REACTIVE Brilliant YELLOW 3GL(REACTIVE BRILLIANT YELLOW B-4GLN));
(7)BLACK POWDER(REACTIVE BLUE 203(REACTIVE NAVY BLUE GG));
(8)DARK RED POWDER(REACTIVE YELLOW 131(REACTIVE ORANGE C-3R)); (9)RED POWDER(REACTIVE DEEP RED WNN(REACTIVE SCARLET SNE)); (10)RED POWDER(REACTIVE ORANGR107(REACTIVE GOLDEN YELLOW RNL); (11)BROWN POWDER(REACTIVE RED 198(REACTIVE RED BRN)).
*********************************************************************** TESTS CONDUCTED:
AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S) ***********************************************************************
TO BE CONTINUED
China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00282680 TESTS CONDUCTED
1 TOTAL IRON (Fe) CONTENT
AS PER CLIENT’S REQUEST, ACID DIGESTION METHOD WAS USED AND TOTAL IRON CONTENT WAS DETERMINED BY INDUCTIVELY COUPLED ARGON PLASMA SPECTROMETRY.
TESTED SAMPLE RESULT IN ppm
(1) 44
(2) 94
(3) 69
(4) 218
(5) 104
(6) 568
(7) 207
(8) 35
写新年的作文(9) 134
(10) 80
(11) 152
ppm = PARTS PER MILLION = mg/kg
2 TOTAL COPPER (Cu) CONTENT
AS PER CLIENT’S REQUEST, ACID DIGESTION METHOD WAS USED AND TOTAL COPPER CONTENT WAS DETERMINED BY INDUCTIVELY COUPLED ARGON PLASMA SPECTROMETRY.
TESTED SAMPLE RESULT IN ppm
(1) <5
(2) 14800
(3) <5
(4) <5
(5) <5
(6) <5
(7) <5
(8) <5
(9) <5
(10) <5
(11) 13
ppm = PARTS PER MILLION = mg/kg
< = LESS THAN
***********************************************************************
TO BE CONTINUED
China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00282680 TESTS CONDUCTED
3 TOTAL ZINC (Zn) CONTENT
AS PER CLIENT’S REQUEST, ACID DIGESTION METHOD WAS USED AND TOTAL ZINC CONTENT WAS DETERMINED BY INDUCTIVELY COUPLED ARGON PLASMA SPECTROMETRY.
TESTED SAMPLE RESULT IN ppm
(1) <5
(2) 102
(3) <5
(4) <5
(5) <5
(6) 10
(7) <5
(8) <5
哭泣的情人
(9) <5
(10) <5
(11) 21
ppm = PARTS PER MILLION = mg/kg
< = LESS THAN
4 TOTAL CHROMIUM (Cr) CONTENT
AS PER CLIENT’S REQUEST, ACID DIGESTION METHOD WAS USED AND TOTAL CHROMIUM CONTENT WAS DETERMINED BY INDUCTIVELY COUPLED ARGON PLASMA SPECTROMETRY.
TESTED SAMPLE RESULT IN ppm
(1) 16
(2) <5
(3) <5
(4) <5
(5) <5
(6) <5
(7) <5
(8) <5
(9) <5
(10) <5
(11) <5
ppm = PARTS PER MILLION = mg/kg
< = LESS THAN
***********************************************************************
TO BE CONTINUED
China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00282680 TESTS CONDUCTED
5 TOTAL LEAD (Pb) CONTENT
AS PER CLIENT’S REQUEST, ACID DIGESTION METHOD WAS USED AND TOTAL LEAD CONTENT WAS DETERMINED BY INDUCTIVELY COUPLED ARGON PLASMA SPECTROMETRY.
TESTED SAMPLE RESULT IN ppm
(1) <5
(2) <5
(3) <5
(4) <5
(5) <5
(6) <5
(7) <5
(8) <5
(9) <5
(10) <5
(11) <5
做梦梦到兔子ppm = PARTS PER MILLION = mg/kg
< = LESS THAN
6 TOTAL CADMIUM (Cd) CONTENT
AS PER CLIENT’S REQUEST, ACID DIGESTION METHOD WAS USED AND TOTAL CADMIUM CONTENT WAS DETERMINED BY INDUCTIVELY COUPLED ARGON PLASMA SPECTROMETRY.
TESTED SAMPLE RESULT IN ppm
(1) <5
(2) <5
(3) <5
(4) <5
(5) <5
(6) <5
(7) <5
为什么放鞭炮
(8) <5
(9) <5
(10) <5
(11) <5
ppm = PARTS PER MILLION = mg/kg
< = LESS THAN
**********************************************************************
TO BE CONTINUED中学优秀作文
China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00282680 TESTS CONDUCTED
7 TOTAL MERCURY (Hg) CONTENT
AS PER CLIENT’S REQUEST, ACID DIGESTION METHOD WAS USED AND TOTAL MERCURY CONTENT WAS DETERMINED BY INDUCTIVELY COUPLED ARGON PLASMA SPECTROMETRY.
TESTED SAMPLE RESULT IN ppm
(1) <1
(2) <1
(3) <1
(4) <1
(5) <1
(6) <1
(7) <1
恩典
(8) <1
(9) <1
(10) <1
(11) <1
ppm = PARTS PER MILLION = mg/kg
< = LESS THAN
8 TOTAL ARSENIC (As) CONTENT
AS PER CLIENT’S REQUEST, ACID DIGESTION METHOD WAS USED AND TOTAL ARSENIC CONTENT WAS DETERMINED BY INDUCTIVELY COUPLED ARGON PLASMA SPECTROMETRY.
圣诞节几月几号
TESTED SAMPLE RESULT IN ppm
(1) <5
(2) <5
(3) <5
(4) <5
(5) <5
(6) <5
(7) <5
(8) <5
手机刷机怎么刷
(9) <5
(10) <5
(11) <5
ppm = PARTS PER MILLION = mg/kg
< = LESS THAN
**********************************************************************
TO BE CONTINUED