DKD/DAkkS Calibration Certificate
5色吧
The calibration laboratory D-K-15141-01-00 at burster praezisionsmesstechnik gmbh & co kg is supervid by DAkkS (Deutsche Akkreditierungsstelle GmbH) according to ISO 17025.
吊顶材料哪种好It can prove its status by a certificate and is authorized to issue calibration certificates with the DAkkS logo and with the DKD logo (Deutscher Kalibrierdienst).
The calibration certificates are internationally approved by multilateral contracts.
Manufacturer Calibration Certificate
Plea refer to DKD/DAkkS Calibration Certificate but with reduced accuracy. The calibration resistors can also be deliv-ered with a manufacturer calibration certificate. It confirms the traceability of the ud condary voltage and resistance stan-dards to the national standards according to DIN ISO 9000ff and is guaranteed by our certified calibration laboratory (D-K-15141-01-00)
Application
The 0.02 class calibration resistors excel in their modern design and small mechanical dimensions. Their ruggedness also ensures a long life.
Calibration resistors of the 1240 ries are ud wherever very constant operating standards are required. Typical main areas of application therefore include:
► When normal resistors prove to be too large scale ► For test and calibration of resistance measurement devices
► For tests on electrical temperature measuring equipment ► For laboratory tup of a Wheatstone bridge
► As shunt resistor for accurate current measurement ► As part of standard equipment in rearch laboratories ► For a large part of measurements in calibration laboratory A test certificate according to ISO 9000 with detailed technical data is included in the scope of delivery of the high-quality
calibration resistors.
Calibration Resistor
情感问题
Model 1240
c u r r e
n t t e r
m i n a l
s
n
Low capacitance and low inductance design
捕捉拼音>福字最漂亮写法
n Suitable for direct current and technical frequencies n High stability < ± 0.01 % over years
最大的蛋
910-001240EN-5072-021514
1240 EN - 2
Technical Data
Resistance material: 25 µΩ ... 100 m Ω MANGANIN ®s heet 200 m Ω ... 100 k Ω ZERANIN ® wire Temperature coefficient: approx. ± 10 ppm/K MANGANIN ®s heet approx. ± 2 ppm/K ZERANIN ® wire Calibration temperature: 23 °C ± 3 K (< 0.5 W load)Surface temperature: max. 85 °C Thermal resistance: 11 K/W Test voltage: 2900 VDC (resistance element-housing)Nominal insulation voltage: 650 VDC (insulated mounting required)Insulation resistance: > 100 M ΩSpecifications: according IEC 60477Dimensions 100 µΩ ... 100 K Ω: (H x W x D) 97 x 38 x 61 [mm] 25 µΩ: (H x W x D) 97 x 38 x 81 [mm]Weight 100 µΩ ... 100 K Ω: 250 g 25 µΩ: 400 g
小区规划图Order Information
Calibration Resistor 100 m Ω
Order code 1240-0.1DKD/DAkkS Calibration Certificate Order code 12DKD-1240Manufacturer Calibration Certificate
Order code 12WKS-1240
Adapter model 2394
for the check-up and calibration of our resistance measurement devices models 2304 and 2316-V000X
voltage tap