B-400继电器完整资料

更新时间:2023-07-21 16:25:48 阅读: 评论:0

MORS SMITT RELAIS
INSTANTANEOUS RELAYS - B
FEATURES: q Conforms with French Railway Standard CF 62-002 and NFF 62-002. q Compact space saving package size. q Plug-in design with cure locking feature for maximum ea of maintenance - i. e. - no wires need to be disconnected or other hardware removed for relay inspection or replacement. q Resistance to impact and vibration conform to standards in force for Railway Transported Equipment. q Positive mechanical keying of relay to socket is accomplished by keystuds supplied for relay and socket. q Weld no transfer safety contacts are standard.
INSULATION MATERIALS
Note: The materials have been tested
for fire propagation and smoke emission according to Standards NFF16101 and NFF16102 and have been approved to go on the English/French Train Channel Shuttle.
COVER BASE
Polycarbonate Polyester Melamine
GENERAL SPECIFICATIONS - ELECTRICAL DESCRIPTION Relay has 4 changeover double break contacts (Form Z). Nominal load current: 12 Amps (10 Amps according to CF 62-002). Instantaneous contact changeover with contact wiping action in both positions. (Socket Nominal Load Current: 12 Amps) Hard silver overlay laminated to copper. Initial: 10 milliohms max. at 10 Amps. End of life: 40 milliohms max. at 10 Amps. 2000 VAC for 1 minute between contacts. 2600 VAC for 1 minute between contacts, coil and frame. ≥ 1000 Megohms at 500 VDC At 24 VDC contacts will withstand making 200 Amps at L/R = 0 for 10 ms duration for 10 operations at the rate of 1 operation per minute. To reduce or eliminate spurious EMI interference, an optional double zener diode (Transil) can be supplied connected to the coil.
Page - 43
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
ACTION
CONTACT MATERIAL CONTACT RESISTANCE
DIELECTRIC STRENGTH
INSULATION RESISTANCE CONTACT OVERLOAD WITHSTAND
COIL OVERVOLTAGE PROTECTION
MORS SMITT RELAIS
INSTANTANEOUS RELAYS - B
GENERAL SPECIFICATIONS - - MECHANICAL & ENVIRONMENTAL OPERATING TEMPERATURE RANGE OPERATING POSITION CONTACT LIFE (MECHANICAL) WEIGHT VIBRATION -40°C TO 80°C. May be mounted in any attitude. 100 million cycles. Relay: 450 grams (15.87 ounces). The Tests are conducted in the X, Y & Z planes at frequency between 10 & 150 cycles (sinusoidal) at 2 g. Tests are applied in both directions in the X, Y & Z planes. Three successive shocks are administered consisting of the positive component of sinusoidal with a value of 30 g, 18 milliconds. 93% RH, 40° C for 4 days. 5% NaCl, 35° C for 4 days.
SHOCK
HUMIDITY SALT MIST
MECHANICAL OUTLINE & MOUNTING HOLE LAYOUTS DYNAMIC RELAY SELECTION CURVES CONTACT DESIGN
REFERENCE "LB" REFERENCE "CB"
CHANGE OVER DOUBLE BREAK CONTACTS WITH WELD NO TRANSFER FEATURE
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Page - 44
MORS SMITT RELAIS
INSTANTANEOUS RELAYS - B
STANDARD MODELS WITH COIL DATA & CONTACT DATA
KEYING NOMINAL VOLTAGE OP. VOLTAGE RANGE COIL DATA NOMINAL POWER HOLD SPECIFIED DROPOUT SPECIFIED RESISTANCE (OHMS)† TIME CONSTANT (L/R)‡ NOMINAL CURRENT SPECIFIED BREAKING CONTACT DATA CAPACITY & LIFE CONTACT CLOSURE TIM
E CONTACT OPENING TIME MINIMUM CONTACT CONTINUITY NO. OF CONTACTS CONTACT MATERIAL * with P option: less than 95 ms 3 Amps at 72 VDC 1 Amp at 72 VDC 3 Amp at 220 VAC, 50 Hz. ME
12VDC 8/16
AG
24 VDC 16/33
FL
36 VDC 25/45
DG
48 VDC 33/60
BG
72 VDC 48/90
手脱皮缺维生素什么
US
96VDC 65/120
EG
115 VDC 77/144
FG
550VDC 400/660 4 Watts 300 50 75500 40 ms
UT
EM
监视者们CG
220 VAC 176/242 3 VA 129 21 14350 40ms
700VDC 127 VAC 450/900 4.2 Watts 380 60 115000 40 ms 88/143 4 VA 71.5 12 4000 40ms
3.5 Watts 3.5 Watts 3.5 Watts 3.5 Watts 3.5 Watts 3.8 Watts 3.5 Watts 6.25 1.25 40 40 ms 13.5 2.5 170 40 ms 21 3.5 390 40 ms 28.5 4.5 625 40 ms 40.5 6.5 1600 40 ms 50 9 2400 40 ms 60 11.5 4000 40 ms
12 Amps (Resistive) Time constant: 0 ms Time constant: 30 ms Power factor=1 Electrical life: 5,000,000 operations Electrical life: 2,500,000 operations Electrical life: 2,500,000 operations Electrical life: 500,000 operations
Drop-out* NC: less than 25 ms NO: less than 15 ms
Lamp filament circuit: 200 watts at 72 VDC
Pick-up NO: less than 55 ms NC: less than 50 ms
小海豚简笔画
20 milliamps at 24 VDC 4 changeover double break contacts (Form Z) Hard silver overlay laminated to copper † - Coil resistance tol.: ± 8% at 20° C ‡ - valid for clod relay
SCHEMATICS AND RELAY PIN CORRESPONDENCE
A1 C1 A2 C2 A3 C3 A4 C4
A1 C1 A2 C2 A3 C3 A4 C4
A1 C1 A2 C2 A3 C3 A4 C4
B1
B1
B1
B2
B2
B2
B3
B3
B3
B4 D1 D2 D3 D4
B4 D1 D2 D3 D4
B4 D1
D3 D4
VDC Models (no Transil protection)
1 a 2
S T N
VDC Models (with Transil protection)
3
K J H
VAC Models
4
L M G
Relay pin correspondence (rear view of relay shown) Example: BG keying
b c d
R P O
a b c
D C B A E F W V
X Y Z U
d
N.B.1: On 500VDC and 700VDC relays, coil is connected only to D1 and D4. D2 and D3 are not wired and transil or diode protections are not available. N.B.2: Transil not needed on VAC coil relays.
D1
Led (V) option (respect polarity)
D2
D3 D4
iphone死机
1
2
3
4 Page - 45
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
D2
MORS SMITT RELAIS
INSTANTANEOUS RELAYS - B
MODEL B - RELAY ORDER GUIDE To specify a relay, a complete part number must first be determined. The boxes below have brief descriptions of the options above and the allowable optionsuffixes beneath. Complete descriptions of the options are listed below. Simply fill in all boxes with lected option suffixes for the complete part number. Contacts
C/O
Relay Model B
Nominal Voltage Keying
中国房地产现状12 24 36 48 72 96 115 550 700 127 220 ME AG FL DG BG US EG FG UT EM CG
Coil Overvoltage Protection S P
LED Coil Voltage Indicator V
Relay Cover Language on Type Test Report F 1 2
4 0 0
-
Relay Model: - Contacts: - Nominal Voltage & Keying:
NO
NC
B 400 12VDC 24VDC 36VDC 48VDC 72VDC 96VDC 115VDC 550VDC 700VDC 127VAC 220VAC S P V F
= = = = = = = = = = =
- Coil Overvoltage protection: (surge suppressor) (controlled avalanche diode)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Specify for all part numbers. Specify for all part numbers. ME AG FL DG BG US EG FG UT EM CG (Select one from above according to operating voltage) Indicates no coil protection. Indicates Transil coil protection. Indicates controlled avalanche diode coil protection. (Select one from above and specify) Indicates no LED Indicates LED (Select one from above and specify) Indicates relay cover with lock pins Indicates relay cover for Wire Locking Spring (Select one from above according to me
chanical outline & mounting hole layout) French Example of a complete English relay part number: Spanish (Select one from B 400 24 AG S V F above & specify)
- LED Coil Voltage Indicator:
- Relay Cover Type:
- Language ud on Parameters Test Report:
1 2
SOCKETS ORDER GUIDE & PACKAGING REFERENCE "SB"
Page - 46
B 400 36 FL 1
MORS SMITT RELAIS
MECHANICAL OUTLINE & MOUNTING HOLE LAYOUT - LB
MECHANICAL OUTLINE & MOUNTING HOLE LAYOUT #1 Relay shown with SINGLE FASTON (5 X 0.8 mm) type socket EA 104 and Locking Bracket 905846.
36mm (1.417") 55mm (2.165") 48mm (1.890)
1.2mm (.047")
1.2mm (.047")
10 mm (.394") clearance required above relay to remove from socket.
Max. thickness: 4mm (0.157")
114mm (4.488")
105mm (4.134") 85mm (3.346")
6mm (.236")
EA104 Tightening torque: 0.4 Nm (0.30ft-lbs) Nut, hex M3
EA104
24mm (.945")
word组合Socket Tab
Mounting Hole Layout: 44mm (1.732") 30mm (1.181")
Bottom View
7mm (.276")
10mm = .394" 20mm = .787"
30mm (1.181")
6.5mm (.256") 4 10
5mm (.197")
1 A 62mm (2.441") B C D
2
3
八年级物理试卷= 54mm (2.126") 42mm (1.653")
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
41mm (1.617")
min. spacing 62mm (2.44")
Faston Wire: Max. 2.5mm2 (14 AWG)
=
雷雨戏剧
10 43mm (1.693") 46mm (1.811") 6.5mm (.256")
min. spacing: 52mm (2.05")
3.2mm (.126") Dia. 3 holes
Page - 229

本文发布于:2023-07-21 16:25:48,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/89/1090761.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

下一篇:指示语deixis
标签:简笔画   现状   试卷   小海豚
相关文章
留言与评论(共有 0 条评论)
   
验证码:
推荐文章
排行榜
Copyright ©2019-2022 Comsenz Inc.Powered by © 专利检索| 网站地图