Ferrogard GS1 & GS2
Description
除夕守岁
The Ferrogard range of magnetically actuated safety switches offers Non contact reliability together with tolerance to misalignment. They are designed to be installed so that when a guard door is
opened, the action of the magnetic actuator being removed from the switch opens the N.C. safety contacts which are intended for the isolation of control power to a machine primary control element.The GS1 and GS2 are designed for heavy duty applications. The GS1 is houd in a stainless steel or brass housing. The GS2 offers the same characteristic as the GS1, but in an Ex housing for hazardous locations.
Unlike some magnetic switches the Ferrogards have protected safety contacts to help ensure that they do not fail to danger.
All Ferrogards have internal non-rettable overload protection on the safety contact. They should be protected by an external fu rated as shown in the specifications table.
See the Explosion Proof ction on page 16-1 for more information on the EX version of the Ferrogard GS2.
Features
•Non contact actuation
•High tolerance to misalignment •High switching current (2A AC)•Metal housings (IP 68)•
固体酸奶Ex version available
Specifications
Standards
EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1
Category
Cat. 1 Device per EN954-1
Dual channel interlocks suitable for Cat. 3 or 4 systems
好词好段摘抄大全Approvals
GS1 and GS2 GS2 Ex CE marked for all applicable directives
and cULus
EExd IIC T6 Baefa
Operating Distance – Make
GS1
GS212mm (0.47in)
苏格拉底的名言
15mm (0.59in)
Operating Distance – Break
GS1
GS223mm (0.91in)
26mm (1.02in)Closing Time 3.0ms Dropout Time 2.1ms Bounce Time
0.7ms Initial Contact Resistance 15mW Initial Capacitance, T erminal to T erminal
0.65pF Initial Insulation Resistance, T erminal to T erminal 1 x 106 ΩSafety Contact Switching Capability
250V AC 2A max Safety Contact External Fusing
< 1.6A quick blow Min Initial Breakdown Voltage
600V AC
Operating T emperature -25°C to +125°C (-13° to +257°F)Enclosure Protection IP68 (NEMA 6P)
Cable
GS1 Brass Stainless Steel
GS20.75 mm 2 (18AWG) 2 wire
Grey PVC Jacket OD 6mm (0.24in)
0.75 mm 2 (18AWG) 2 wire
White PVC Jacket OD 7mm (0.28in)
1.34 mm 2 (16AWG) 2 wire Braided Polyolefin Jacket OD (0.32in)
Ca Material Stainless Steel or Brass
Mounting
Any Position
M3 mounting curity screws included.
Weight (not including cable)
GS1 Brass GS1 Steel Actuator
381g (0.84lbs)388g (0.86lbs)
116g (0.26lbs)Electrical Life 1 X 106 at rated load Mechanical Life 10 X 106
Vibration 15g, 20 to 1000Hz Shock 50g
Ex Version
See Explosion Proof Section
榨菜鸡蛋汤Ferrogard GS1 & GS2
Product Selection
Accessories
Approximate Dimensions—mm (inches)
Dimensions are not intended to be ud for installation purpos.水瓶座性格男
Typical Wiring Diagrams
Note:
Application Details
See page 3-54 for operating principles and mounting examples.
Safety Contact Switching Capability
Safety Contacts
Auxiliary Contacts
Connection Housing T ype Catalogue Number 250V AC, 2A
1 N.C.
None
2m Cable
Brass GS 1
440N-G02048Stainless Steel
440N-G020493m Cable
Brass GS 2 Ex
440N-H02046Stainless Steel
早上犯困
440N-H02047
Description
Ud with Page Number
Catalogue Number Actuator, Alnico Brass Switch —440N-A02056Actuator, Epoxy-painted
烟斗Stainless Steel
—
440N-A02057
Cable
QD
Safety N.C.Fu Externally
Ferrogard Applications
Application Details
Encapsulated in the Ferrogard is a unique high power industrial reed, capable of switching up to 15A. The need switch is de-rated by a non rettable overload protection fu. On prenting the actuator to the switch, the high intensity magnetic field from the actuator caus the contacts to clo. On removing the actuator (opening the door), the safety contacts open.
Mounting Example 1
Door Clod, Machine RUN
Door Opened, Machine STOP , Door Covering Switch
Note: Whenever possible, the units should be mounted so that no access can be obtained to the switch when the guard door is open, thus preventing attempts to defeat the safety system.
Operating Principle
Ferrogard Applications
Application Details
Typical Applications
Note: Under the requirements of the Machinery Directive all machinery must undergo risk
asssment to determine the necessary level (or category) of the safety related control system or ha
zard avoidance measures. While the Ferrogard complies with the requirements of EN1088 it may not be suitable for all types of machinery or environments. Where magnetic materials are prent or if it is foreeable that through machine function or u. Ferrogard operation by magnates other than the supplied actuator is possible, then u of an alternative Allen-Bradley Guardmaster switch is recommended. Other Non contact options include: Ferrocode (which utilizes additional coding techniques preventing them from being overridden by simple means). Alternatively additional measures may be taken to prevent the Ferrogard being easily bypasd. Consideration should be given to the recommended installation example given in the instructions and tho in EN1088.
Note: Removable guards using Non contact switches may require two switches, one at either side of the guard, or the u of a flap to prevent initial lifting of the non-interlocked edge.
Sliding Guard
Hinged Guard
Removable Guard