38.3 Lithium metal and lithium ion batteries
38.3.1 Purpo电饭煲蒸饭
This ction prents the procedures to be followed for the classification of lithium metal and lithium ion cells and batteries (e UN Nos. 3090, 3091, 3480 and 3481, and the applicable special provisions of Chapter 3.3 of the Model Regulations).
38.3.2 Scope
38.3.2.1 Lithium metal and lithium ion cells and batteries shall be subjected to the tests, as required by special provisions 188 and 230 of Chapter 3.3 of the Model Regulations prior to the transport of a particular cell or battery type. Cells or batteries which differ from a tested type by:
(a) For primary cells and batteries, a change of more than 0.1 g or 20% by mass,
whichever is greater, to the cathode, to the anode, or to the electrolyte;
(b) For rechargeable cells and batteries, a change in Watt-hours of more than 20% or an
increa in voltage of more than 20%; or
(c) A change that would materially affect the test results,
shall be considered a new type and shall be subjected to the required tests.
In the event that a cell or battery type does not meet one or more of the test requirements, steps shall be taken to correct the deficiency or deficiencies that caud the failure before such cell or battery type is retested.
38.3.2.2 For the purpos of classification, the following definitions apply:
Aggregate lithium content means the sum of the grams of lithium content contained by the cells comprising a battery.
Battery means one or more cells which are electrically connected together by permanent means, including ca, terminals, and markings.
NOTE: Units that are commonly referred to as "battery packs", "modules" or "battery asmblies" having the primary function of providing a source of power to another piece of equipment are for the purpos of the Model Regulations and this Manual treated as batteries.
Button cell or battery means a round small cell or battery when the overall height is less than the diameter.
Cell means a single encad electrochemical unit (one positive and one negative electrode) which exhibits a voltage differential across its two terminals. Under the Model Regulations and this Manual, to the extent the encad electrochemical unit meets the definition of "cell" herein, it is a "cell", not a "battery", regardless of whether the unit is termed a "battery" or a "single cell battery" outside of the Model Regulations and this Manual.
Component cell means a cell contained in a battery.
Cycle means one quence of fully charging and fully discharging a rechargeable cell or battery.
Disasmbly means a vent or rupture where solid matter from any part of a cell or battery penetrates a wire mesh screen (annealed aluminium wire with a diameter of 0.25 mm and grid density of 6 to 7 wires per cm) placed 25 cm away from the cell or battery.
Effluent means a liquid or gas relead when a cell or battery vents or leaks.
First cycle means the initial cycle following completion of all manufacturing process.
Fully charged means a rechargeable cell or battery which has been electrically charged to its design rated capacity.
Fully discharged means either:
a primary cell or battery which has been electrically discharged to remove 100% of its rated
capacity; or
a rechargeable cell or battery which has been electrically discharged to its endpoint voltage as
specified by the manufacturer.
Large battery means a lithium metal battery or lithium ion battery with a gross mass of more than 12 kg.
Large cell means a lithium metal cell in which the lithium content of the anode, when fully charged, is more than 12 g, or in the ca of a lithium ion cell, means a cell with a Watt-hour rating of more than 150 Wh.
Leakage means the escape of material from a cell or battery.
Lithium content is applied to lithium metal and lithium alloy cells and batteries, and for a cell means the mass of lithium in the anode of a lithium metal or lithium alloy cell, which for a primary cell is measured when the cell is in an undischarged state and for a rechargeable cell is measured when the cell is fully charged. The lithium content of a battery equals the sum of the grams of lithium content contained in the component cells of the battery.
Lithium ion cell or battery means a rechargeable electrochemical cell or battery in which the positive and negative electrodes are both intercalation compounds (intercalated lithium exists in an ionic or quasi-atomic form with the lattice of the electrode material) constructed with no metallic lithium in either electrode.
A lithium polymer cell or battery that us lithium ion chemistries, as described herein, is regulated as a lithium ion cell or battery.
Mass loss means a loss of mass that exceeds the values in Table 38.3.2.2 below. In order to quantify the mass loss, the following procedure is provided:
()100M M M (%) loss Mass 1
21×−=
where M 1 is the mass before the test and M 2 is the mass after the test. When mass loss does not exceed the values in Table 38.3.2.2, it shall be considered as "no mass loss".
Table 38.3.2.2: Mass loss limit
Mass M of cell or battery Mass loss limit
上班使我快乐图片非洲疣猪M < 1 g 0.5%
1 g < M < 5 g 0.2%
M ≥ 5 g
0.1%
Primary means a cell or battery which is not designed to be electrically charged or recharged.
Prismatic cell or battery means a cell or battery who ends are similar, equal and parallel rectilinear figures, and who sides are parallelograms.
Protective devices means devices such as fus, diodes and current limiters which interrupt the curr
ent flow, block the current flow in one direction or limit the current flow in an electrical circuit.
Rated capacity means the capacity, in ampere-hours, of a cell or battery as measured by subjecting it to a load, temperature and voltage cut-off point specified by the manufacturer.
Rechargeable means a cell or battery which is designed to be electrically recharged.
Rupture means the mechanical failure of a cell container or battery ca induced by an internal or external cau, resulting in exposure or spillage but not ejection of solid materials.
Short circuit means a direct connection between positive and negative terminals of a cell or battery that provides a virtual zero resistance path for current flow.
Small battery means a lithium metal battery or lithium ion battery with a gross mass of not more than 12 kg.
Small cell means a lithium metal cell in which the lithium content of the anode, when fully charged, is not more than 12 g, or in the ca of a lithium ion cell, means a cell with a Watt-hour rating of not more than 150 Wh.
Type means a particular electrochemical system and physical design of cells or batteries.
Undischarged means a primary cell or battery that has not been wholly or partly discharged.
Venting means the relea of excessive internal pressure from a cell or battery in a manner intended by design to preclude rupture or disasmbly.
Watt-hour rating, expresd in Watt-hours, is calculated by multiplying a cell’s or battery’s rated capacity, in ampere-hours, by its nominal voltage.
38.3.3 When a cell or battery type is to be tested under this sub-ction, the number and condition of cells and batteries of each type to be tested are as follows:
(a) When testing primary cells and batteries under tests 1 to 5 the following shall be tested
in the quantity indicated:
(i) ten cells in undischarged states;
(ii) ten cells in fully discharged states;
(iii) four small batteries in undischarged states;
穿越明朝的小说
(iv) four small batteries in fully discharged states;
(v) four large batteries in undischarged states; and
(vi) four large batteries in fully discharged states.
(b) When testing rechargeable cells and batteries under tests 1 to 5 the following shall be
tested in the quantity indicated:
(i) ten cells at first cycle, in fully charged states;
(ii) four small batteries at first cycle, in fully charged states;
(iii) four small batteries after 50 cycles ending in fully charged states;
(iv) two large batteries at first cycle, in fully charged states; and
(v) two large batteries after 25 cycles ending in fully charged states.
(c) When testing primary and rechargeable cells under test 6, the following shall be tested
in the quantity indicated:
(i) for primary cells, five cells in undischarged states and five cells in fully
discharged states;
(ii) for component cells of primary batteries, five cells in undischarged states and
five cells in fully discharged states;
(iii) for rechargeable cells, five cells at first cycle at 50% of the design rated
capacity; and
(iv) for component cells of rechargeable batteries, five cells at first cycle at 50% of
the design rated capacity.
For prismatic cells, ten test cells are required instead of the five described above, so
that the procedure can be carried out on five cells along the longitudinal axes and,
屈原的诗有哪些
parately, five cells along the other axes. In every ca, the test cell is only subjected
to one impact.
(d) When testing rechargeable batteries under test 7, the following shall be tested in the
quantity indicated:
(i) four small batteries at first cycle, in fully charged states;
(ii) four small batteries after 50 cycles ending in fully charged states;
唯美的古诗
(iii) two large batteries at first cycle, in fully charged states; and
(iv) two large batteries after 25 cycles ending in fully charged states.
Batteries not equipped with overcharge protection that are designed for u only in a
battery asmbly, which affords such protection, are not subject to the requirements of
this test.
(e) When testing primary and rechargeable cells under test 8, the following shall be tested
in the quantity indicated:
(i) ten primary cells in fully discharged states;
(ii) ten rechargeable cells, at first cycle in fully discharged states; and
(iii) ten rechargeable cells after 50 cycles ending in fully discharged states.
(f) When testing a battery asmbly in which the aggregate lithium content of all anodes,
when fully charged, is not more than 500 g, or in the ca of a lithium ion battery, with
a Watt-hour rating of not more than 6 200 Watt-hours, that is asmbled from cells or
batteries that have pasd all applicable tests, one battery asmbly in a fully charged
state shall be tested under tests 3, 4 and 5, and, in addition, test 7 in the ca of a
rechargeable battery asmbly. For a rechargeable battery asmbly, the asmbly
qq好友批量删除
shall have been cycled at least 25 cycles.
When batteries that have pasd all applicable tests are electrically connected to form a battery asmbly in which the aggregate lithium content of all anodes, when fully charged, is more than 500 g, or in the ca of a lithium ion battery, with a Watt-hour rating of more than 6 200 Watt-hours, that battery asmbly does not need to be tested if it is equipped with a system capable of monitoring the battery asmbly and preventing short circuits, or over discharge between the batteries in the asmbly and any overheat or overcharge of the battery asmbly.
38.3.4 Procedure
Each cell and battery type shall be subjected to tests 1 to 8. Tests 1 to 5 shall be conducted in quence on the same cell or battery. Tests 6 and 8 shall be conducted using not otherwi tested cells or batteries.Test 7 may be conducted using undamaged batteries previously ud in Tests 1 to 5 for purpos of testing on cycled batteries.
38.3.4.1 Test T.1: Altitude simulation
管理类的书籍38.3.4.1.1Purpo
This test simulates air transport under low-pressure conditions.
38.3.4.1.2Test procedure
Test cells and batteries shall be stored at a pressure of 11.6 kPa or less for at least six hours at ambient temperature (20 ± 5 °C).
38.3.4.1.3 Requirement
Cells and batteries meet this requirement if there is no mass loss, no leakage, no venting, no disasmbly, no rupture and no fire and if the open circuit voltage of each test cell or battery after testing is not less than 90% of its voltage immediately prior to this procedure. The requirement relating to voltage is not applicable to test cells and batteries at fully discharged states.
38.3.4.2 Test T.2: Thermal test
38.3.4.2.1 Purpo
This test asss cell and battery al integrity and internal electrical connections. The test is conducted using rapid and extreme temperature changes.
38.3.4.2.2 Test procedure
Test cells and batteries are to be stored for at least six hours at a test temperature equal to 75 ± 2 °C, followed by storage for at least six hours at a test temperature equal to - 40 ± 2 °C. The maximum time interval between test temperature extremes is 30 minutes. This procedure is to be repeated 10 times, after which all test cells and batteries are to be stored for 24 hours at ambient temperature (20 ± 5 °C). For large cells and batteries the duration of exposure to the test temperature extremes should be at least 12 hours.
38.3.4.2.3Requirement
Cells and batteries meet this requirement if there is no mass loss, no leakage, no venting, no disasmbly, no rupture and no fire and if the open circuit voltage of each test cell or battery after testing is not less than 90% of its voltage immediately prior to this procedure. The requirement relating to voltage is not applicable to test cells and batteries at fully discharged states.