Quick Installation Guide
V200 INPUT MONITOR INTERFACE
PROPRIETARY INFORMATION. This document contains proprietary information which may not be duplicated, published or disclod to others, or ud for any purpo without written permission from HID Corporation. 2004 © HID Corporation. All rights rerved.
Document Version 1.1
August 4, 2005
Document Number 6080-908B
9292 Jeronimo Road
Irvine, CA 92618-1905
Contents
Introduction (3)
Parts List (3)
Product Specifications (3)美丽校园作文
Cable Specifications (3)
Overview (4)英雄联盟昵称
Step 1Preparations (4)
1.1What you need before getting started (4)
俄罗斯翻译
1.2V200 (4)
Step 2Hardware Installation (5)
2.1Mounting Instructions (5)
2.2Wiring VertX (5)
Contact Information (8)
Introduction
VertX™ CS is the first family of access controllers designed specifically for alarm dealers for direct connection to central stations. Becau it was designed with central station in mind, VertX CS works with software from leading central station automation providers, including Bold Technologies, DICE and GE MAS.
The V200 is designed to be controlled by a VertX V1000 Access Controller that will also manage communications with the central station automated software. The V200 Input Monitor Interface panel monitors as many as 16 input points.
Parts List
Parts List (included) Quantity
呼兰河传好词VertX™ V200 Input Monitor Interface
Note: The V200 panel has a plastic ba
and is covered with a Plastic or Mylar cover.
1
Mounting screws 4
2.2K EOL resistors 4
Quick Installation Guide 1
Installation Wiring Diagram Example 1
Note: A VertX V1000 Access Controller is required.
Product Specifications
Description Specification
Power Supply 12-16VDC骆驼刺
企业承担社会责任
Maximum current at 12VDC per V200 1 Amp
Average operating current at 12VDC 60mA
Operating temperature range 32°-122°F (0°-50°C)
Humidity 5% to 95% non-condensing
盘中诗Cable Specifications
Cable Type Length Specification
RS-485 * 4000 feet (1220 m) to V1000 Belden 3105A, 22AWG twisted pair, shielded 100Ωcable, or equivalent.
Input Circuits * 500 feet (150 m) 2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C (18AWG), or equivalent.
Output Circuits * 500 feet (150 m) 2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG), or equivalent.
Power Supply
+12 VDC IN
---- Refer to your Power Supply Installation Guide. * Minimum wire gauge depends on cable length and current requirements.
Terminating Jumper
Overview
The following outlines what is required to install the V200 Input Monitor Interface panel.
Step 1 Preparations
1.1 What you need before getting started
Prior to starting the installation, plea completely read through this guide.
CAUTION: The V200 is nsitive to Electrostatic Discharges (ESD). Obrve precautions while
handling the circuit board asmbly by using proper grounding straps and handling precautions at all times.
1.2 V200
1. If the V200 will be attached to the end of the RS-485 bus, install a
terminating jumper on the termination resistor pins P8 on the cover (P10 on the PCB) of the V200.
2. If the V200 is being installed as part of an array, or in a third party
enclosure, follow the directions provided by the Integrator or Dealer.
Pin # P7
1 +12VDC
2 Ground
3
Bat Fail -
4
Bat Fail +
5 AC Fail -
6 AC Fail +
7 Tamper
-
8 Tamper
+
Step 2 Hardware Installation
2.1 Mounting Instructions
1. The V200 should always be mounted in a cure area.
2. Mount the V200 using the four mounting screws (provided) or other appropriate fasteners. Place the
fasteners in the corner holes of the ba.
护士个人年度工作总结3. The V200 panel can be stacked with or without the cover. Do not remove the plastic ba. Make sure
to position in such a way as to provide room for wiring, air-flow and cable runs.
2.2 Wiring VertX
1. Power and Alarm input connections: Connect power by providing 12VDC to the P7 connector.
+12VDC goes to Pin 1 and Ground on Pin 2. The Bat Fail, AC Fail, and Tamper switch inputs are
wired as shown in the table. Connect the Bat Fail and AC Fail inputs to battery low/failure and AC
failure contacts provided on the power supply. Connect the Tamper input to a tamper switch on the
enclosure.
2. RS-485 Connections: Connect the V200 to the V1000 through the RS-485 cable. See the V1000
Quick Install Guide for further information.
CAUTION: Connectors on the V200 sides are positioned to be mirror images and are not interchangeable once the installation is complete. Therefore, you cannot unplug the connector from
one side of the board and plug it into the corresponding connector on the other side.