Remove the specimen,cover,and cool in a desiccator for 1h.
Weigh the cooled specimen to the nearest 0.1mg.
12.Calculation
12.1The volatile material is given by the following equa-
tion:
V 5~S o !2~S h !/S o 3100(1)
where:V 5volatiles,%,S o 5original specimen mass,and
S h 5heated specimen mass.
13.Report
13.1Report results obtained from two individual determi-
nations and their average to the nearest 0.01%.
14.Precision and Bias 3
14.1This precision and bias ction has been prepared in
accordance with Practice D 4483.Refer to Practice D 4483for
terminology and other statistical details.
14.2The precision results in this precision and bias ction
give an estimate of the precision of this test method with the
materials (rubbers)ud in the particular interlaboratory pro-
grams as described below.The precision parameters should not
be ud for acceptance/rejection testing of any group of
materials without documentation that they are applicable to
tho particular materials and the specific testing protocols that
include this test method.
14.3A Type 1(interlaboratory)precision was evaluated in
1986.Both repeatability and reproducibility are short term.A
period of a few days parates replicate test results.A test result
is the mean value,as specified by this test method,obtained on
two determinations or measurements of the property or param-
eter in question.
14.4Three different materials were ud in the interlabora-
写事作文500tory program.The were tested in ven laboratories on two
different days.
14.5The results of the precision calculations for repeatabil-
ity and reproducibility are given in Table 1,in ascending order
of material average or level,for each of the materials evalu-
ated.
彰显的近义词
14.6The precision of this test method may be expresd in the format of the following statements which u an “appro-priate value”of r,R ,(r )or (R ),that is,that value to be ud in decisions about test results (obtained with the test method).The appropriate value is that value of r or R associated with a mean level in Table 1clost to the mean level under consideration at any given time,for any given material in routine testing operations.14.7Repeatability —The repeatability,r ,of this test method has been established as the appropriate value tabulated in Table 1.Two single test results,ob
tained under normal test method procedures,that differ by more than this tabulated r (for any given level)must be considered as derived from different sample populations.14.8Reproducibility —The reproducibility,R ,of this test method has been established as the appropriate value tabulated in Table 1.Two single test results obtained in two different laboratories,under normal test method procedures,that differ by more than the tabulated R (for any given level)must be considered to have come from different or nonidentical sample populations.N OTE 1—The values of r and R are relatively large,whereas the average or mean test level is small (clo to zero).This is typical for this type of precision measurement process.This should be kept in mind whenever u is made of r and R .14.9The relative repeatability (r )and reproducibility (R )have been omitted from Table 1since the level of values tested was extremely low and approached the limits of nsitivity of the test method.Under the circumstances the relative values become trivial.14.10Bias —In test method terminology,bias is the differ-ence between an average test value and the reference (or true)test property value.Reference values have not been evaluated for this test method.Bias,therefore,cannot be determined.p -PHENYLENEDIAMINE ANTIDEGRADANT 15.Scope 15.1This test method describes the determination of vola-tile materials in p -phenylenediamine antidegradants and is bad on the mass loss upon heating at 70°C.15.2The measured loss on heating reprents volatile or-ganics plus moisture.16.Summary of Test Method 16.1The p -phenylenediamine test unit is weigh
ed before and after heating for 3h at 70°C.The measured difference in mass is the volatile material.17.Significance and U 17.1The quantity of volatile material in p -phenylenediamines can affect performance of the anti-degradants in rubber if they exceed critical levels.17.2Since the loss on heating is an empirical and nonspe-cific method,it is esntial that the prescribed analysis condi-tions (sample container,oven temperature,oven air flow,cooling conditions,etc.)be controlled so that results are meaningful.17.3Prolonged heating or overheating of the sample or the
3Supporting data are available from ASTM Headquarters.Request RR:D11-
1047.TABLE 1Type 1Precision Results—Volatile Materials,Percent
Material Aver-age Within Laboratory A Between Laboratory A
S r r S R R
General Purpo Ground Sulfur
0.070.0180.0530.0450.127
Oil Treated,90%Insolule Sulfur—A
0.260.0250.0730.1300.368
Oil Treated,90%Insoluble Sulfur—B
0.320.0420.1190.1510.427
Pooled Values B 0.220.0300.0870.1190.338
A S r 5repeatability standard deviation.
r 5repeatability 52.833the square root of the repeatability variance.
S R 5reproducibility standard deviation.
R 5reproducibility 52.833the square root of the reproducibility variance.
B No values
omitted.
test unit can result in high heat loss values due to oxidative generation of volatile degradation products.
18.Apparatus
18.1See Section6.
19.Sampling
19.1To ensure homogeneity,at least250g of the“lot”sample should be well blended prior to removing the test unit.
20.Procedure
20.1Dry a clean weighing bottle and stopper(stopper removed)for30min in the specified oven t at70°C.Place the bottle and stopper in the desiccator and allow them to cool to room temperature.Weigh the bottle with a stopper to the nearest0.1mg.
20.2Weigh a nominal20-g test unit into the weighing bottle to the nearest0.1mg.
20.3Place the weighing bottle containing the test unit and the stopper(with the stopper removed)in the specified oven, which has equilibrated at70°C,for3h.
20.4After the heating period,replace the stopper and transfer the bottle to the desiccator for a period of time sufficient for the asmbly to equilibrate at room temperature. Reweigh the bottle to the nearest0.1mg.
20.5Repeat the procedure on a cond test unit.
21.Calculation
21.1Calculate the percent heating loss to the nearest0.1% as follows:
H5@~B2C!/~B2A!#3100(2) where:
H5heating loss,%,
A5mass of weighing bottle and stopper,g,
B5mass of weighing bottle,stopper,and test unit before heating,g,and世界上人口最多的国家是哪个国家
C5mass of weighing bottle,stopper,and test unit after heating,g.
22.Report
孕酮低是什么原因造成的
22.1Report the following information:
22.1.1Proper identification of the sample,and
22.1.2Results obtained from two individual determinations and their average,reported to the nearest0.01%.
23.Precision and Bias3
23.1This precision and bias ction has been prepared in accordance with Practice D4483.Refer to Practice D4483for terminology and other statistical details.
锱铢必较
23.2A Type1(interlaboratory)precision was evaluated in 1987.Both repeatability and reproducibility are short term.A period of a few days parates replicate test results.A test result is the mean value,as specified by this test method,obtained on two determinations or measurements of the property or param-eter in question.
23.3Four different materials were ud in the interlabora-tory program.The were tested in six laboratories on two different days.
23.4The results of the precision calculations for repeatabil-ity and reproducibility are given in Table2,in ascending order of material average or level,for each of the materials evalu-ated.
23.5The precision of this test method may be expresd in the format of the following statements which u an“appro-priate value”of r,R,(r),or(R),that is,that value to be ud in decisions about test results(obtained with the test method). The appropriate value is that value of r or R associated with a mean level in Table2clost to the mean level under consideration at any given time,for any given material in routine testing operations.
23.6Repeatability—The repeatability,r,of this test method has been established as the appropriate value tabulated in Table2.Two single test results,obtained under normal test method procedures,that differ by more than this tabulated r (for any given level)must be considered as derived from different or nonidentical sample populations.
23.7Reproducibility—The reproducibility,R,of this test method has been established as the appropriate value tabulated in Table2.Two single test results obtained in two different laboratories,under normal test method procedures,that differ by more than the tabulated R(for any given level)must be considered to have come from different or nonidentical sample populations.
23.8The relative repeatability(r)and reproducibility(R) have been omitted from Table2since the level of values tested was extremely low and approached the limits of nsitivity of the test method.Under the circumstances the relative values become trivial.
23.9Bias—In test method terminology,bias is the differ-ence between an average test value and the reference(or true) test property value.Reference values have not been evaluated for this test method.Bias,therefore,cannot be determined.
24.Keywords
24.1antidegradants;rubber chemicals;sulfur;volatile con-tent
TABLE2Volatile Materials of p-Phenylenediamine,Percent
Material
Aver-
age
晋武帝司马炎Within Laboratory A Between Laboratory A
S r r S R R
M1-6PPD0.060.0220.0620.0290.083
M2-IPPD0.080.0040.0110.0260.075
M3-BMPPD0.190.0340.0980.0730.026
烧烤配方M4-DTPD0.040.0020.0050.0190.055 Pooled Values B0.090.0210.0610.0450.129
A S
r
5repeatability standard deviation.
r5repeatability52.833the square root of the repeatability variance.河南省考报名时间
S R5reproducibility standard deviation.
R5reproducibility52.833the square root of the reproducibility variance.
B No values
omitted.
The American Society for Testing and Materials takes no position respecting the validity of any patent rights asrted in connection with any item mentioned in this standard.Urs of this standard are expressly advid that determination of the validity of any such patent rights,and the risk of infringement of such rights,are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed everyfive years and if not revid,either reapproved or withdrawn.Your comments are invited either for revision of this standard or for additional standards and should be addresd to ASTM Headquarters.Your comments will receive careful consideration at a meeting of the responsibl
e technical committee,which you may attend.If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards,100Barr Harbor Drive,West Conshohocken,PA19428.

本文发布于:2023-06-19 04:12:20,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/89/1045035.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:国家   河南省   近义词   造成   配方   时间
相关文章
留言与评论(共有 0 条评论)
   
验证码:
推荐文章
排行榜
Copyright ©2019-2022 Comsenz Inc.Powered by © 专利检索| 网站地图