Functional Symbols and Application Notes
n See Application Note B, and in Model Code on next page.Model Types KHDG5V Shown
梦见前男友是什么意思Simplified symbol Model Types KAHDG5V Shown K(A)FDG5V symbols identical, but omit
pilot-stage LVDT s
过年的音乐
Simplified symbol
Detailed symbol Detailed symbol
Spool Types Application Notes
A. Main-Spool Options
Spools shown are meter-in/meter-out
types. Center-condition options are
types 2 and 33.
B. Internally Piloted Models Differ from detailed symbols above by omission of plug n and the blocking of port X by the mating surface.
Type 5
Type 33Type 2
Series type designator
儿童节的英文A =Integral amplifier
Omit for non-integral amplifier Feedback arrangement
曼谷时间
F =From main stage only
H =From pilot and main stages
Mounting size code (ISO 4401)5
=057
=078=08Spool type, flow rating and metering See “Functional Symbols ” on previous page ∆p = 5 bar (72 psi) per metering flow path, e.g. B to T Symmetric spools For K*DG5V-5 valves:2C100N =100 L/min (26 US gpm)33C80N =80 L/min (21 US gpm)5C85N =85 L/min (22 US gpm)For K*DG5V-7 valves:2C200N =200 L/min (52 US gpm)33C160N =160 L/min (42 US gpm)5C200N =200 L/min (52 US gpm)For K*DG5V-8 valves:2C300N =300 L/min (79 US gpm)33C270N =270 L/min (71 US gpm)5C300N =300 L/min (79 US gpm)Asymmetric spools First figure (***N) is flow rating P-A, or A-T (“A ” port flow); last figure (N***) is
flow rating P-B, or B-T (“B ” port flow)
For K*DG5V-5 valves:2C70N45=70 L/min (18.5 US gpm), “A ” port flow 45 L/min (11.9 US gpm), “B ”
port flow 33C65N40=65 L/min (17.2 US gpm), “A ” port flow 40 L/min (10.6 US gpm), “B ” port flow For K*DG5V-7 valves:2C150N85=150 L/min (40 US gpm),“A ” port flow
85 L/min (22.4 US
gpm), “B ” port flow
33C130N65=130 L/min (33.3 US
gpm), “A ” port flow
65 L/min (17.2 US
gpm), “B ” port flow
For K*DG5V-8 valves:
2C280N200=280 L/min (74 US gpm),
“A ” port flow
200 L/min (52 US gpm),
“B ” port flow
33C250N170=250 L/min (66 US gpm),
“A ” port flow
170 L/min (45 US gpm),
“B ” port flow
Pilot supply
EX =External through integral reducer
X =Internal through integral reducer
Solenoid electrical connector
U1=ISO 4400/DIN 43650, non-integral
amplifier type only
F =Flying lead, integral amplifier type
only Electrical connection (KAF valves only)PD7=7-pin connector with plastic plug.See Warning note below.Design number 10 ries for K(A)FDG5V-7/8 models 20 ries for K(A)H models 30 ries for K(A)FDG5V-5models Subject to change. Installation dimensions unaltered for design numbers *0 to *9 inclusive.Solenoid and LVDT Plugs Supplied with valve.2Model Code
51** - C - *******K **
***- * -- ** -34678
(A)(E)DG5V *-X - VM - H1 -123
45678Warning
To conform to the EC Electromagnetic Compatibility directive (EMC) this KA valve must be fitted with a metal 7-pin plug. The screen of the cable must be curely connected to the shell of the metal connector. A suitable IP67 rated connector is available from Vickers, part no. 934939. Alternatively a non IP67 rated connector is available from ITT-Cannon, part no.CA 02 COM-E 14S A7 P .
Additionally the cable must be fitted with a ferrite EMC suppression core not more than 4cm from the connector referred to above. Suitable types include Farnell 535-898 or Farnell 535-904 which snap fit over the cable.大寒日
The plastic plug, part number 694534, is only suitable for u in a aled electromagnetic environment or outside of the European Community.
麦冬的副作用Operating Data
Performance data is typical with fluid at 36 cSt (168 SUS) and 50_C (122_F) while using the basic Vickers power amplifier. KF/HDG5V and KAF/HDG5V Valves
KF/HDG5V Valves
KAF/HDG5V Valves
Maximum Pressures, bar (psi)
Model Pilot Pressure
Source Ports
P, A and B T X Y
K(A)FDG5V-7/8Internal or external350 (5000) s350 (5000)350 (5000) s 4 (58) K(A)*DG5V-5External315 (4500)210 (3000)210 (3000) n 4 (58) Internal315 (4500) n100 (1450)315 (4500) n 4 (58) K(A)HDG5V-7/8Internal or external350 (5000) n350 (5000)350 (5000) n 4 (58) s25 (363) min. pressure at X for externally piloted models or at P and X for internally piloted models.
n45 (653) min. pressure at X for externally piloted models or at P and X for internally piloted models.
Minimum Recommended Flow Rates
For spool types 2C and 33C
∆p = 10 bar (145 psi) for looped flow P-A-B-T (or P-B-A-T)
Valve Size/Spool Code Min. Flow Rate
设置头像L/min in3/min
K(A)FDG5V-5-2C100N K(A)FDG5V-5-33C80N K(A)FDG5V-7-2C200N K(A)FDG5V-7-33C160N K(A)FDG5V-8-2C300N K(A)FDG5V-8-33C270N 1,0
1,0
2,0
2,0
3,0
维生素c摄入量
3,0
60
60
121
121
182
182
K(A)HDG5V-5-2C100N K(A)HDG5V-5-33C80N K(A)HDG5V-7-2C200N K(A)HDG5V-7-33C160N K(A)HDG5V-8-2C300N K(A)HDG5V-8-33C270N 0,5
0,5
1,0
1,0
1,5
1,5
30
30
60
60
91
91