TRIBON肘板建模总结

更新时间:2023-06-10 16:20:20 阅读: 评论:0

标准肘板
是否用系统标准做
普通板架
非标准肘板(用板架做)
肘板板架
肘板的分类
2臂
臂的个数
3臂
销售攻心术搭接
是否搭接
不搭接
板-板(板:面板在特殊情况下也属于板,
肘板连接面板与面板(线)时,面板
就属于板了。线,包括直线,船体曲
线也可属于板的范畴)
连接构件的种类板-型材
型材-型材
1.板-型材:有一臂与当前板架型材相交(终止
与型材,不一定是第一根),另一臂连接外部
的型材。
语法1~8)
2.板-型材:材包括S,L,F
3.板-板(同上)
4.型材-型材
七月的天山5.板-型材搭接
6.型材-型材搭接
7.自由边(FREE SIDE)
8.三点
以K结尾-折边
以R结尾-自由边为圆弧
以肘板类型结尾的字母分以L结尾-自由边为直线
以P结尾-自由边为带焊接的面板NOTE:1.肘板不能开孔(HOLE),但可以开CUTOUT.
感恩节在几月几日
2.肘板类型以字母开始,最好以字母结尾,一般4个字符,不超过8个。
3.带加强筋的肘板用板架做,自由边做边界。
语法1
1.Note that the side B always connects to an "external
profile" and the side A always ends at a profile on the current panel.
2.The references before the slash (if any) concern the
adjoining panel and bars on it (or in the shell),
references after the slash concerns bars on the current panel.
3.Normally the A-measure is calculated automatically from the distance between the overlapped profile and the intercting profile. In the Extended Bracket Handling the details about the connection of the bracket to the intercting profile are controlled by the customer t-up. However, a clearance can be introduced between the bracket and the intercting profile (e M1 below).
A, C, CK:
The brackets stop against the flange of the panel, unless a stiffener on the panel is explicitly given.
Cutouts will be made automatically for all stiffeners, pasd by the bracket.
捐躯赴国难视死忽如归是谁写的
For C and CK, the A-measure can be given in input provided it gives an overlap in the range 50-150 mm.
L:
This bracket stops against the clost intercting stiffener irrespective of side. For details about the "connection", e below
All other brackets will go against the clost intercting profile and this is found automatically.
4.
生龙活虎的意思
defines the length of the B-arm.
<length_B>::= <number>
父亲的脚印For built-in brackets the following rules apply:
∙It can be given for all brackets and it must be given for all brackets except A, C and CK for which the
default is (-) 0.4 * A (cf the figure below).suv哪款车最好
∙For L, a given value must be in the interval (0.4 * A, 0.6 * A).
∙When given for A, C and CK, the measure is interpreted in a different way if it is positive or negative, cf the figure below
Figure 18:8. Interpretation of B for brackets A, C and C
5.
The bracket parameter C is always calculated automatically (when relevant) according to the Design Standards or as t-up by the customer in the Extended Bracket Handling.  <length_C>::= <number>
If given, C must be smaller than the automatically calculated value.
Remark:
For the bracket types A, C and CK, Hull Modelling will automatically switch to a bracket alternative with a notch R75 at edge c if C > 180 (i.e. COR=2->3 and 3->6, respectively).
6.
M1 C learance between the intercted profile and the bracket (cf. the comment on A above).
Special error signals:
什么是奇数和偶数
640  A given A-measure does not give an overlap in the

本文发布于:2023-06-10 16:20:20,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/82/920537.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:肘板   型材   面板   结尾
相关文章
留言与评论(共有 0 条评论)
   
验证码:
推荐文章
排行榜
Copyright ©2019-2022 Comsenz Inc.Powered by © 专利检索| 网站地图