PHILIPS TOPFET high side switch BUK224-50Y 数据手册

更新时间:2023-06-04 23:57:50 阅读: 评论:0

Philips Semiconductors
Product specification
TOPFET high side switch BUK224-50Y
SMD version of BUK223-50Y
DESCRIPTION
QUICK REFERENCE DATA
Monolithic single channel high side SYMBOL PARAMETER
MIN.UNIT protected power switch in
TOPFET2 technology asmbled in I L
Nominal load current (ISO)12A a 5 pin plastic surface mount package.
SYMBOL PARAMETER
MAX.UNIT APPLICATIONS
V BG Continuous off-state supply voltage 50
V General controller for driving
I L Continuous load current
25A lamps, motors, solenoids, heaters.
T j Continuous junction temperature 150˚C R ON
On-state resistance T j  = 25˚C
30
m Ω
FEATURES
Vertical power TrenchMOS Low on-state resistance CMOS logic compatible Very low quiescent current Overtemperature protection Load current limiting Latched overload and short circuit protection
Overvoltage and undervoltage shutdown with hysteresis On-state open circuit load detection
Diagnostic status indication Voltage clamping for turn off of inductive loads
ESD protection on all pins Rever battery, overvoltage and transient protection
PINNING - SOT426
PIN CONFIGURATION
春节团拜会
SYMBOL
查询BUK224-50Y供应商
LIMITING VALUES
Limiting values in accordance with the Absolute Maximum System (IEC 134)SYMBOL PARAMETER
CONDITIONS
MIN.MAX.UNIT V BG Continuous supply voltage 050V I L Continuous load current T mb ≤ 100˚C -25A P D Total power dissipation T mb ≤ 25˚C -80W T stg Storage temperature轮状病毒
-55175˚C T j Continuous junction temperature 1-150˚C T sold Mounting ba temperature during soldering -
260˚C Rever battery voltages 2-V BG Continuous rever voltage -16V -V BG Peak rever voltage -32
V
Application information R I , R S
External resistors 3to limit input, status currents
室雅兰香3.2-k Ω
Input and status
农谚拼音
I I , I S Continuous currents -55mA I I , I S
Repetitive peak currents δ ≤ 0.1, tp = 300 µs -50
50
mA
Inductive load clamping
I L  = 10 A, V BG  = 16 V E BL
Non-repetitive clamping energy
T j  = 150˚C prior to turn-off
-270mJ
ESD LIMITING VALUE
SYMBOL PARAMETER
CONDITIONS
MIN.MAX.UNIT V C
Electrostatic discharge capacitor Human body model;-2
kV
voltage
C = 250 pF; R = 1.5 k Ω
THERMAL CHARACTERISTICS
SYMBOL PARAMETER CONDITIONS
MIN.
TYP.
MAX.
UNIT
Thermal resistance 4R th j-mb
Junction to mounting ba
--  1.25
1.56
关于月亮的谜语K/W
1 For normal continuous operation.  A higher T j  is allowed as an overload condition but at the threshold T j(TO) the over temperature trip operates
to protect the switch.
2 Rever battery voltage is allowed only with external resistors to limit the input and status currents to a safe value.  The connected load must
limit the rever load current.  The internal ground resistor limits the rever battery ground current. 
Power is dissipated and the T j rating must be obrved.
3 To limit currents during rever battery and transient overvoltages (positive or negative).
4 Of the output power MOS transistor.
STATIC CHARACTERISTICS
Limits are at -40˚C ≤ T
mb ≤ 150˚C and typicals at T
mb
= 25 ˚C unless otherwi stated.
SYMBOL PARAMETER CONDITIONS MIN.TYP.MAX.UNIT Clamping voltages
V
BG Battery to ground I
G
网易云网易云= 1 mA505565V
V
BL Battery to load I
L
= I
G
= 1 mA505565V
-V
LG Negative load to ground I
L
= 10 mA182328V
-V
LG Negative load voltage1I
L
= 10 A; t
p
= 300 µs202530V Supply voltage battery to ground
V
BG
Operating range2-  5.5-35V
Currents9 V ≤ V
BG
≤ 16 V
I B Quiescent current3V
LG
= 0 V--20µA
T
犬冠状病毒mb
= 25˚C-0.12µA
I L Off-state load current4V
BL
= V
BG
--20µA
T
mb
= 25˚C-0.11µA
I G Operating current5I
L
= 0 A-24mA
I L Nominal load current6V
BL
= 0.5 V12--A
Resistances V
BG
I
L
t
p
T
mb
R
ON
On-state resistance79 to 35 V10 A300 µs25˚C-2230mΩ
150˚C--55mΩ
R
ON
On-state resistance  6 V10 A300 µs25˚C-2838mΩ
150˚C--70mΩ
R
G Internal ground resistance I
G
= 10 mA95150190Ω
1 For a high side switch, the load pin voltage goes negative with respect to ground during the turn-off of an inductive load.
怎样说好普通话2 On-state resistance is incread if the supply voltage is less than 9 V.  Refer to figure 8.
3 This is the continuous current drawn from the supply when the input is low and includes leakage current to the load.
4 The measured current is in the load pin only.
5 This is the continuous current drawn from the supply with no load connected, but with the input high.
6 Defined as in ISO 10483-1.  For comparison purpos only.  This parameter will not be characterid for automotive PPAP.
7 The supply and input voltage for the R
ON  tests are continuous.  The specified pul duration t
p
refers only to the applied load current.
INPUT CHARACTERISTICS
9 V ≤ V BG  ≤ 16 V.  Limits are at -40˚C ≤ T mb  ≤ 150˚C and typicals at T mb  = 25 ˚C unless otherwi stated.SYMBOL PARAMETER CONDITIONS MIN.TYP.MAX.UNIT I I Input current
V IG  = 5 V 2090160µA V IG Input clamping voltage I I  = 200 µA
5.578.5V V IG(ON)Input turn-on threshold voltage -  2.43V V IG(OFF)Input turn-off threshold voltage    1.5  2.1-V ∆V IG Input turn-on hysteresis -0.3-V I I(ON)Input turn-on current V IG  = 3 V --100µA I I(OFF)
Input turn-off current
V IG  = 1.5 V 10
--µA
STATUS CHARACTERISTICS
The status output is an open drain transistor, and requires an external pull-up circuit to indicate a logic high.Limits are at -40˚C ≤ T mb  ≤ 150˚C and typicals at T mb  = 25 ˚C unless otherwi stated.  Refer to TRUTH TABLE .SYMBOL PARAMETER
CONDITIONS MIN.TYP.MAX.UNIT V SG Status clamping voltage I S  = 100 µA    5.578.5V V SG Status low voltage
I S  = 100 µA
--1V T mb  = 25˚C
-0.70.8V I S Status leakage current V SG  = 5 V
--15µA T mb  = 25˚C
-0.11µA I S Status saturation current 1V SG  = 5 V
2
7
12
mA
Application information R S
External pull-up resistor
-47
-k Ω
OPEN CIRCUIT DETECTION CHARACTERISTICS
An open circuit load can be detected in the on-state.  Refer to TRUTH TABLE .Limits are at -40˚C ≤ T mb  ≤ 150˚C and typical is at T mb  = 25 ˚C.SYMBOL
PARAMETER
CONDITIONS MIN.
TYP.
MAX.
UNIT
Open circuit detection
9 V ≤ V BG  ≤ 35 V
I L(TO)Low current detect threshold
0.3-2A T j  = 25˚C
0.51  1.5A ∆I L(TO)
Hysteresis
-0.2
-A
1 In a fault condition with the pull-up resistor short circuited while the status transistor is conducting.  This condition should be avoided in order to
prevent possible interference with normal operation of the device.
UNDERVOLTAGE & OVERVOLTAGE CHARACTERISTICS
Limits are at -40˚C ≤ T
mb ≤ 150˚C and typicals at T
mb
= 25 ˚C.  Refer to TRUTH TABLE.
SYMBOL PARAMETER CONDITIONS MIN.TYP.MAX.UNIT Undervoltage
V
BG(UV)
Low supply threshold voltage12  4.2  5.5V ∆V BG(UV)Hysteresis-0.5-V Overvoltage
V
BG(OV)
High supply threshold voltage2404550V ∆V BG(OV)Hysteresis-1-V TRUTH TABLE
ABNORMAL CONDITIONS
DETECTED LOAD
INPUT SUPPLY LOAD OUTPUT STATUS DESCRIPTION UV OV LC SC OT
L X X X X X OFF H off
H00000ON H on & normal
H00100ON L on & low current detect
H10X X X OFF H supply undervoltage lockout
H01X00OFF H supply overvoltage shutdown H0001X OFF L SC tripped
H00001OFF L OT shutdown3
KEY TO ABBREVIATIONS
L logic low UV undervoltage
H logic high OV overvoltage
X don’t care LC low current or open circuit load
0condition not prent SC short circuit
1condition prent OT overtemperature
1 Undervoltage nsor caus the device to switch off and ret.
2 Overvoltage nsor caus the device to switch off to protect its load.
3 The status will continue to indicate OT (even if the input goes low) until the device cools below the ret threshold.  Refer to OVERLOAD
PROTECTION CHARACTERISTICS.

本文发布于:2023-06-04 23:57:50,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/82/865811.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:拼音   谜语   说好
相关文章
留言与评论(共有 0 条评论)
   
验证码:
推荐文章
排行榜