jedec 高压蒸煮PCT

更新时间:2023-06-03 04:16:47 阅读: 评论:0

JEDEC
STANDARD Accelerated Moisture Resistance - Unbiad Autoclave
JESD22-A102-C
(Revision of JESD22-A102-B)
DECEMBER 2000
JEDEC SOLID STATE TECHNOLOGY ASSOCIATION
5年级下册英语
JEDEC Standard No. 22-A102-C
Page 1 ACCELERATED MOISTURE RESISTANCE - UNBIASED AUTOCLAVE
(From JEDEC Board Ballot JCB-00-55, formulated under the cognizance of the JC-14.1 Subcommittee
on Reliability Test Methods for Packaged Devices.)
1  Purpo
The " Unbiad Autoclave Test" is performed to evaluate the moisture resistance integrity of non-hermetic packaged solid state devices using moisture condensing or moisture saturated steam envir
onments. It is a highly accelerated test which employs conditions of pressure, humidity and temperature under condensing conditions to accelerate  moisture penetration through the external protective material (encapsulant or al) or along the interface between the external protective material and the metallic conductors passing through it.  This test is ud to identify failure mechanisms internal to the package and is destructive.
2  Scope
This test method applies primarily to moisture resistance evaluations and robustness testing.  Samples are subjected to a condensing, highly humid atmosphere under pressure to force moisture into the package to uncover weakness such as delamination and metallization corrosion.  This test is ud to evaluate new packages or packages that have undergone changes in materials (e.g. mold compound, die passivation) or design (e.g. die/paddle sizes).  However, this test should not be applied on laminate or tape bad FR4 material, polyimide tape or equivalent.
Some cautions should be considered when performing  this test and evaluating test results. Failure mechanisms, both internal (e.g., due to plastic package swelling from saturation) and external (e.g. dendritic growth of conducting material between leads), may be produced which are not applicable t
o the  intended application u conditions. Most miconductor components are not rated for field applications conditions exceeding 95% RH, including condensing moisture such as rain or fog. The combination of high humidity, high temperature (>T g) and high pressure may produce unrealistic material failures becau absorbed moisture typically decreas the glass transition temperature for most polymeric materials.  Extrapolation of autoclave test results to arrive at an application life should be accomplished with care.
3  Apparatus
The test requires a pressure chamber capable of maintaining a specified temperature, and relative humidity.小屁孩日记4
3.1  Records
A permanent record of the temperature profile for each test cycle is recommended, so the stress conditions can be verified.
Test Method A102-C
(Revision of Test Method A102-B)
JEDEC Standard No. 22-A102-C
Page 2
仓鼠吃什么
Test Method A102-C
(Revision of Test Method A102-B)
3  Apparatus (cont'd)
3.2  Devices under stress
Devices under stress shall be no clor than 3 cm from the internal chamber surface, and must not be subjected to direct radiant heat.
3.3  Ionic contamination
Ionic contamination of the test apparatus and storage chamber shall be controlled to avoid test artifacts.
3.4  Distilled or deionized water
Distilled or deionized water with a minimum resistivity of 1 megaohm-cm at room temperature shall be ud.
kg是什么意思4  Test conditions求职信的格式
Test conditions consist of a temperature, relative humidity, vapor pressure and duration.
Table 1 — Temperature, relative humidity and pressure 2,3
Temperature 1 (dry bulb °C) Relative humidity 1 (%)
Vapor pressure (psia/kPa) 121 ± 2
100% 29.7/205
怎样学好地理NOTES
1  Tolerances apply to the entire usable test area.
2  The test conditions are to be applied continuously except during any interim readouts. For interim readouts, devices should be returned to stress within the time specified in 5.2
3  Previous revisions of this document specified the following test conditions:
Condition    Duration
A  24 hours (-0,+2)
B 48 hours (-0, +2)
C 96 hours (-0, +5)
D  168 hours (-0, +5)
E  240 hours (-0, +8)
F  336 hours (-0, +8).
The stress duration is specified by internal qualification requirements, JESD47 or the applicable procurement document.  96 hours duration is typical for this test.
JEDEC Standard No. 22-A102-C
Page 3
脸发热
4  Test conditions (cont’d)
CAUTION:  For plastic-encapsulated microcircuits, it is known that moisture reduces the effective glass transition temperature of the molding compound.  Stress temperatures above the effective glass transition temperature may lead to failure mechanisms unrelated to operational u.
5  Procedure
The test devices shall be mounted in a manner which expos them to the specified temperature and humidity conditions.  Exposure of devices to ambient environments greater than 100 o C and less than 10% R.H. shall be avoided, particularly during stress ramp-up, ramp-down and the pre-readout drying period. Care should be taken through equipment control or cool down procedures to prevent destructive depressurization of the parts under test.  Frequent cleaning of the test chamber is necessary to ensure elimination of contamination.
5.1  Test clock张大千简介
The test clock starts when the temperature and relative humidity reach the t points specified in clau
4.0 and stops at the beginning of ramp-down.
5.2  Readout
ramp-down with room temperature testing done first in the quence of testing.  Note:  For intermediate readouts, devices shall be returned to stress within 96 hours of the end of ramp-down.  The rate of moisture loss from devices after removal from the chamber can be reduced by placing the devices in aled moisture barrier bags, the bags should be non-vacuum aled without a N2 purge and without dessicant.  When devices are placed in aled bags, the "test window clock" runs at 1/3 of the rate of devices expod to the laboratory ambient.  Thus the test window can be extended to as much as 144 hours, and the time to return to stress to as much as 288 hours by enclosing the devices in aled moisture barrier bags.  Devices that exceed the test window clock or extension shall be removed from test and shall have new samples submitted for testing.
Condend moisture on the exterior surface of the device package may be removed through contact with an absorbing medium or isopropyl alcohol.  Becau the purpo of this test is to identify failure mechanisms internal to the package, cleaning of the packaged device or leads is permitted, providin
g it doesn’t induce anomalous failures or obscure valid failures.
5.3  Handling
Hand-coverings which eliminate any source of ancillary contamination or ESD damage shall be ud to handle devices and test fixtures.  Contamination control is important in the application of this test method and any highly-accelerated moisture stress test.
Test Method A102-C
(Revision of Test Method A102-B)
JEDEC Standard No. 22-A102-C
Page 4
Test Method A102-C
(Revision of Test Method A102-B) A device under accelerated moisture resistance shall be defined a failure if its parametric limits are exceeded, or its functionality cannot be demonstrated under nominal and worst-ca conditions as specified in the applicable procurement document or data sheet.  Electrical failures due to external package damage which are an artifact of the test method shall be excluded from the failure classification.
7  Safety
Follow equipment manufacturer's recommendation and local safety regulations.
8  Summary
The following details shall be specified in the applicable procurement document:
(a) Test duration.
(b)
Measurements after test.