DELRIN 150NC010

更新时间:2023-06-01 03:37:02 阅读: 评论:0

DuPont™ Delrin®
acetal resin
Delrin® 150 NC010
Delrin® 150 NC010 is a  high viscosity acetal homopolymer for extrusion process.  It has excellent thermal stability, low die deposit, and enhanced crystallization for low porosity.
Property Test Method Units Value
Identification
Resin Identification ISO 1043POM
Part Marking Code ISO 11469>POM< Mechanical
Yield Stress ISO 527MPa  (kpsi)72  (10.4)
Yield Strain ISO 527%21
Nominal Strain at Break ISO 527%40
Tensile Modulus ISO 527MPa  (kpsi)3100  (450)
Flexural Modulus ISO 178MPa  (kpsi)2900  (420)
Notched Charpy Impact Strength ISO 179/1eA kJ/m2
-30°C (-22°F)9
23°C (73°F)12
炮简笔画Thermal
Deflection Temperature ISO 75-1/-2 °C  (°F)
0.45MPa166  (331)
1.80MPa97  (207)
Melting Temperature ISO 11357-1/-3 °C  (°F)
10°C/min178  (350)
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm.
Test temperatures are 23°C unless otherwi stated.
The DuPont Oval Logo, DuPont™, The miracles of science™ and Delrin® are trademarks or registered trademarks of DuPont Company. Copyright© 2006.
061010/061010 The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; the
data may not be valid for such material ud in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwi.
The data provided should not be ud to establish specification limits or ud alone as the basis of d
esign; they are not intended to substitute for any testing you may
need to conduct to determine for yourlf the suitability of a specific material for your particular purpos. Since DuPont cannot anticipate all variations摘樱桃
in actual end-u conditions DuPont makes no warranties and assumes no liability in connection with any u of this information. Nothing in this publication
is to be considered as a licen to operate under or a recommendation to infringe any patent rights.  DuPont advis you to ek independent counl for a freedom to practice  opinion on the intended application or end-u of our products. CAUTION:  This product is not permitted to be sold for u in medical applications
involving any implantation in the human body or where contact with internal body fluids or tissues will equal or exceed 24 hours.  For applications involving
contact of less than  24 hours, e “DuPont Medical Caution Statement", H-50102 and contact your DuPont sales reprentative.
Delrin® 150 NC010
Property Test Method Units Value
Thermal
CLTE, Parallel ISO 11359-1/-2E-4/C  (E-4/F)
-40 - 23°C (-40 - 73°F)  1.0  (0.56)
23 - 55°C (73 - 130°F)  1.1  (0.61)
55 - 100°C (130 - 212°F)  1.4  (0.78)
CLTE, Normal ISO 11359-1/-2E-4/C  (E-4/F)
-40 - 23°C (-40 - 73°F)0.9  (0.5)
23 - 55°C (73 - 130°F)  1.0  (0.56)
55 - 100°C (130 - 212°F)  1.5  (0.83) Rheological
Melt Mass-Flow Rate ISO 1133g/10 min
190°C, 2.16kg  2.4 Flammability
Flammability Classification IEC 60695-11-10
1.5mm HB
3.0mm HB
Flammability Classification UL94
1.5mm HB
3.0mm HB Temperature Index
RTI, Electrical UL 746B°C
1.5mm50
3.0mm50
RTI, Impact UL 746B°C
1.5mm50
3.0mm50
沟通的意义
RTI, Strength UL 746B°C
1.5mm50
3.0mm85
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm.
Test temperatures are 23°C unless otherwi stated.
The DuPont Oval Logo, DuPont™, The miracles of science™ and Delrin® are trademarks or registered trademarks of DuPont Company. Copyright© 2006.
061010/061010 The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; the
data may not be valid for such material ud in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwi.
The data provided should not be ud to establish specification limits or ud alone as the basis of design; they are not intended to substitute for any testing you may
need to conduct to determine for yourlf the suitability of a specific material for your particular purpos. Since DuPont cannot anticipate all variations
in actual end-u conditions DuPont makes no warranties and assumes no liability in connection with any u of this information. Nothing in this publication
is to be considered as a licen to operate under or a recommendation to infringe any patent rights.  DuPont advis you to ek independent counl for a freedom to practice  opinion on the intended
application or end-u of our products. CAUTION:  This product is not permitted to be sold for u in medical applications
involving any implantation in the human body or where contact with internal body fluids or tissues will equal or exceed 24 hours.  For applications involvingb777
contact of less than  24 hours, e “DuPont Medical Caution Statement", H-50102 and contact your DuPont sales reprentative.
Delrin® 150 NC010
三字经教案Property Test Method Units Value
Other
Density ISO 1183kg/m3  (g/cm3)1420  (1.42)
Water Absorption ISO 62, Similar to%
Immersion 24h0.39
武汉首义广场
Molding Shrinkage ISO 294-4%
Normal, 2.0mm  2.0
Parallel, 2.0mm  1.8
Processing - Injection Molding
Melt Temperature Range °C  (°F)210-220  (410-430)
Melt Temperature Optimum °C  (°F)215  (420)
Mold Temperature Range °C  (°F)80-100  (175-210)
Mold Temperature Optimum °C  (°F)90  (195)
Hold Pressure Range MPa  (kpsi)90-110  (13-16) Processing - Extrusion
Melt Temperature Range °C  (°F)195-205  (385-400)
Melt Temperature Optimum °C  (°F)200  (395)
Processing Moisture Content%<0.2 Processing
Drying Time, Dehumidified Dryer h2-4
Drying Temperature °C  (°F)80  (175)
Processing Moisture Content%<0.2
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm.
Test temperatures are 23°C unless otherwi stated.
The DuPont Oval Logo, DuPont™, The miracles of science™ and Delrin® are trademarks or registered trademarks of DuPont Company. Copyright© 2006.手机信号不稳定
061010/061010 The information provided in this data sheet corresponds to our knowledge on the su
bject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; the
data may not be valid for such material ud in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwi.
The data provided should not be ud to establish specification limits or ud alone as the basis of design; they are not intended to substitute for any testing you may
need to conduct to determine for yourlf the suitability of a specific material for your particular purpos. Since DuPont cannot anticipate all variations
in actual end-u conditions DuPont makes no warranties and assumes no liability in connection with any u of this information. Nothing in this publication
黄山游is to be considered as a licen to operate under or a recommendation to infringe any patent rights.  DuPont advis you to ek independent counl for a freedom to practice  opinion on the intended application or end-u of our products. CAUTION:  This product is not permitted to be sold for u in medical applications
involving any implantation in the human body or where contact with internal body fluids or tissues will equal or exceed 24 hours.  For applications involving
contact of less than  24 hours, e “DuPont Medical Caution Statement", H-50102 and contact your DuPont sales reprentative.