超高效液相色谱法测定Menaquinone-7原料药主成分及有关物质

更新时间:2023-05-20 12:32:46 阅读: 评论:0

超高效液相色谱法测定Menaquinone-7原料药主成分及有关物质
宋怡;孔凡建;李银科;王泉
【摘 要】Raw material drug of Menaquinone-7 was dissolved ultrasonically with ethanol in the dark,and then the principal compound and related substances in the sample were parated on an Agilent Eclip plus C18 chromatographic column (2.1 mm× 50 mm,1.8 μm).The mobile pha was methanol-water (98+2) solution,and the detection wavelengths were 246,270 nm for the determination of principal compound and related substances,respectively.The linearity range of Menaquinone-7 was 0.005-0.400 g · L-1,with detection limit (3S/N) of 0.1 mg · L-1.Recovery rates obtained by standard addition method were in the range of 98.8%-100% and RSDs (n=6) were less than 1.0%.The contents of the principal compound in 2 batches of Menaquinone-7 raw material drug were 98.0% and 98.2%.The mass fraction of single impurity was less than 0.5%,and the mass fraction of total impurities was less than 1.0 %.%Menaquinone-7原料药在避光条件下经无水乙醇超声溶解后,采用Agilent Eclip plus C18色谱柱(2.1 mm×50 mm,1.8μm)分离主成分及有关物质,
以甲醇-水(98+2)混合液为流动相,分别在波长246,270 nm处测定主成分及有关物质.Menaquinone-7的线性范围在0.005~0.400 g·L-1内,检出限(3S/N)为0.1 mg· L-1.加标回收率在98.8%~100%之间,测定值的相对标准偏差(n=6)小于1.0%.测得两批Menaquinone-7原料药中主成分的质量分数分别为98.0%,98.2%,单个杂质质量分数小于0.5%,杂质总质量分数小于1.0%.
【期刊名称】《理化检验-化学分册》
【年(卷),期】2017(053)012
俄罗斯饮食【总页数】5页(P1381-1385)
【关键词】超高效液相色谱法;Menaquinone-7;主成分;有关物质
【作 者】宋怡;孔凡建;李银科;王泉
【作者单位】云南省玉溪市食品药品检验所,玉溪653100;云南省玉溪市食品药品检验所,玉溪653100;玉溪师范学院,玉溪653100;玉溪师范学院,玉溪653100
【正文语种】中 文
觉海
【中图分类】O657.7咋挽留爱情
维生素K是一类天然存在的脂溶性维生素,维生素K 2(甲基萘醌类,Menaquinone,简称MK)是一组在2-甲基-1,4-萘醌母核上有不同长度的聚异戊二烯侧链的化合物。Menaquinone-7(MK-7)属于维生素K 2中的一类,它的侧链含有7个异戊二烯基团,结构式见图1。
维生素 K 2 主要通过微生物发酵产生[1-2],也可由人工合成得到[3]。研究发现,维生素K 2具有治疗和预防骨质疏松[4-6]、促进凝血等功能[7],同时在治疗肝癌[8-9]、乳腺癌[10]等方面表现出良好的疗效。MK-7作为维生素K 2最重要的一类,还具有防止血管钙化,降低冠状动脉心脏病的风险[11],以及治疗类风湿性关节炎的功能[12]。
图1 MK-7的结构式Fig.1 Structural f or mula of MK-7
目前,尚未见到用超高效液相色谱法测定MK-7原料药主成分及有关物质的报道。本工作参
考了国外对母乳、血液、食品中维生素K 2的测定方法[13-17],应用超高相液相色谱分析技术对 MK-7原料药主成分及有关物质进行测定,拟为MK-7质量标准的制定提供参考。
1 试验部分
1.1 仪器与试剂
Agilent 1290 Infinity型超高效液相色谱系统,配二极管阵列检测器(DAD)和Open LAB CDS工作站;TB-215D型十万分之一电子天平;Elga型超纯水机。
对照品溶液:避光操作,称取 MK-7对照品25.21 mg置于25 mL棕色容量瓶中,加无水乙醇超声溶解并稀释至刻度,摇匀,制成对照品储备溶液。移取1.00 mL对照品储备溶液,置于10 mL棕色容量瓶中,加无水乙醇稀释至刻度,摇匀,作为对照品溶液。
MK-7对照品纯度为99.1%,无水乙醇、异丙醇为分析纯,甲醇为色谱纯,试验用水为超纯水。燕园是哪个大学
1.2 仪器工作条件
Agilent Eclip pl us C18 色谱柱 (2.1 mm×50 mm,1.8μm);流动相为甲醇-水(98+2)混合液;流量0.3 mL·min-1;检测波长为246 n m(主成分测定),270 n m(有关物质测定);柱温30℃;进样量2μL。
1.3 试验方法
避光条件下,称取MK-7原料药25.12 mg置于25 mL棕色容量瓶中,加无水乙醇超声溶解并定容,摇匀,制成供试品储备溶液。移取供试品储备溶液1.00 mL置于10 mL棕色容量瓶中,用无水乙醇稀释至刻度,摇匀,配制供试品溶液,在仪器工作条件下进行测定。
移取4.00 mL供试品储备溶液,置于10 mL棕色容量瓶中,加无水乙醇稀释至刻度,摇匀,作为有关物质供试品溶液。移取上述溶液1.00 mL置于50 mL棕色容量瓶中,加无水乙醇稀释至刻度,摇匀,作为有关物质对照溶液,在仪器工作条件下进行测定。
2 结果与讨论
2.1 检测波长的选择
采用二极管阵列检测器对供试品溶液在波长200~400 n m内进行扫描,发现在波长246,270 n m处有最大吸收,见图2。
图2 MK-7紫外吸收光谱Fig.2 UV adsorption spectru m of MK-7
洋气网名
由图2可知:在波长246 n m处,杂质较少,无干扰;在270 n m处,杂质有明显吸收,且基线噪声较小。试验选择270 n m为有关物质的检测波长,246 n m为MK-7的检测波长。
2.2 溶剂的选择
分别用异丙醇、甲醇、无水乙醇溶解并稀释供试品,制成3份质量浓度为0.1 g·L-1的溶液,按仪器工作条件进样分析。3份溶液的峰形及对称性均较好,而异丙醇和无水乙醇能较快溶解样品,甲醇溶解样品的时间较长。从经济性方面考虑,试验选择无水乙醇作为溶剂。
2.3 专属性考察
取0.2 g·L-1供试品溶液共5份,1份在70℃恒温水浴中加热1 h,作为高温破坏溶液;1份
在4300lx的强光下照射1 h,作为光照破坏溶液;其余3份分别加入0.1 mol·L-1盐酸溶液、0.1 mol·L-1氢氧化钠溶液、30 g·L-1过氧化氢溶液各1 mL加热1 h,并调节p H至中性,分别作为酸破坏溶液、碱破坏溶液、氧化破坏溶液。将5份专属性溶液和1份0.2 g·L-1供试品溶液按仪器工作条件,在波长270 n m下进样分析,色谱图见图3。
图3 不同条件下MK-7专属性试验的色谱图Fig.3 Chro matograms of specificity test of MK-7 under different conditions
由图3可知:MK-7在酸、碱、光照、高温及氧化条件下均不稳定,不同程度分解而产生杂质;但在上述色谱条件下各杂质峰与主成分峰均能较好地分离,对MK-7及有关物质的测定无干扰,说明建立的方法具有良好的专属性。由图3还可知:MK-7在碱性条件下几乎完全分解,在光照下产生的杂质较多,说明该物质对光敏感,易被碱破坏,故在生产、运输和储存的过程中应采取避光措施,并避免与碱性物质的接触。
2.4 系统适用性试验
分别将对照品溶液、供试品溶液和空白溶液,按仪器工作条件在波长246 n m处进样分析,
色谱图见图4。MK-7的保留时间为7.05 min,理论塔板数为10 889,拖尾因子为0.94。
2.5 方法学考察
2.5.1 线性范围与检出限
移取MK-7对照品储备溶液适量,配制成质量浓度分别为0.005,0.010,0.025,0.050,0.100,0.200,0.400 g·L-1的对照品溶液系列,按仪器工作条件在波长246 n m处进样分析,记录色谱图及峰面积。以峰面积为纵坐标(y)和MK-7质量浓度为横坐标(x)进行线性回归,MK-7的线性范围为0.005~0.400 g·L-1,线性回归方程为y=1.430×10 4 x-3.620×10 1,相关系数为0.999 8。
按3倍信噪比时的质量浓度计算得检出限(3S/N)为0.1 mg·L-1。
图4 对照品溶液、供试品溶液、空白溶液的色谱图Fig.4 Chr o matograms of standard solution,sa mple solution and blank solution
2.5.2 精密度试验
貂蝉带什么技能平行配制6份供试品溶液,在波长246 n m处进样分析,测得MK-7质量分数的平均值为98.0%,相对标准偏差(RSD)为0.6%,说明方法的精密度较高。
2.5.3 稳定性试验
取供试品溶液,在10℃下避光保存12 h,每隔2 h进样一次,按仪器工作条件在波长246 n m处分析,测得MK-7峰面积的RSD为0.7%。说明供试品溶液在12 h内,10℃避光条件下稳定性良好。
2.5.4 回收试验
称取MK-7供试品适量,按试验方法进行加标回收试验,结果见表1。
表1 回收试验结果Tab.1 Results of test for recovery本底值ρ/(g·L-1)加标量ρ/(g·L-1)测定总量ρ/(g·L-1)回收率/%0.108 3 0.050 0 0.157 7 98.8 0.101 2 0.099 9 0.201 2 100 0.102 1 0.150 0 0.250 9 98.8
2.6 样品分析
称取2批MK-7原料药,按试验方法配制供试品溶液,在波长246 n m处进样分析。按外标法以峰面积计算MK-7的质量分数,结果见表2。
表2 样品中MK-7的测定结果(n=3)Tab.2 Deter mination results of MK-7 in sa mples(n=3)样品批号 测定值w/%RSD/%20160101 98.0 0.5 20160623 98.2 0.6英语演讲稿
2.7 有关物质测定
称取2批MK-7原料药,按试验方法配制有关物质溶液,移取对照溶液2μL,在波长270 n m处进样分析,调节检测灵敏度,使主成分色谱峰的峰高约为满量程的25%,再移取有关物质供试品溶液和对照品溶液各2μL,按仪器工作条件进样分析,记录色谱图至主成分保留时间的3倍,以自身对照法计算杂质含量,结果见表3。

本文发布于:2023-05-20 12:32:46,感谢您对本站的认可!