Technical Documentation Regenerative Turbine Pump with Canned Motor
Y-2951-W-MM
Technical Documentation
Regenerative Turbine Pump with Canned Motor Y-2951-W-MM
Description
Hermetically aled centrifugal pump with can-ned motor.
Impeller (230) and inner magnet (847) are asmbled to the same shaft (211), the shaft is supported by a medium-lubricated sleeve bearing (310). The power transmission from motor to shaft is produced by a rotating field, generated by coils, directly to the inner magnet.
The can (816) parates the pumping chamber from the atmosphere. An integrated electronic circuit provides for the rotating field and controls the pump speed.
The drive is free from bearings and rotating com-ponents: No maintenance is necessary in standard operation.
Applications
The pump can be ud in the following fields of application, e.g.:
Temperature controlling and industrial cooling • cooling of machines, systems and production process
• cooling of industrial and medical lars • climatisation of control cabinets
• tempering devices in laboratory applications Further applications
• drinking water supply in railcars and on ships • etc.
Technical Data
Pumped media Clear or unclear liquids or mixtures without solids and with good lubricating
qualities, not aggressive to the pump components, density and viscosity
similar to water. Other liquids on request.
Temperature / Medium -30 °C up to +80 °C (-22 °F up to +176 °F), medium has to be liquid! Installation Dry installation in buildings or in roofed places outdoors.
Not permitted in Ex-zones.
Ambience -30 °C up to 40 °C (-22 °F up to +176 °F) ambient temperature, max. 80% air
humidity. Protect the pump against ambient atmosphere or vapours with
high concentrations of acids or solvents.
Static system pressure max. 2.5 bar (max. 36.3 psi)
Motor power max. 180 W (0.23 HP), depending on load and speed
Nominal voltage 24 V
Operating voltage 18 to 28 V
Current consumption max. 7.5 A, depending on load and speed
Fu 10 A
Speed 2000 to 5000 rpm, possible parameters t by Speck Pumpen
Direction of rotation Left (view from pump front side), cf. marking on pump connections Protection class IP 54, higher degree of protection on request
Sound pressure level max. 46 db(A) in a distance of 1 m ( 3.3 ft) to all sides
Connecting wire 1000 mm +/- 20 mm (39.3“ +/- 0,8“) insulating ho with loo wire-endings
50 mm (1.9“), isolated without ferrules, 5 mm (0.2“) stripped.
See detailed information in table …wire specification“
Cable connection M16 x 1.5 plastics black
Pumping capacity H max. 45 m (147 ft)
Q max. 12 l/min (3.2 USGPM)
Lifetime 20,000 hours of operation according to standard mode of operation Protection against Not existing, the pump has to be protected against dry running by the ur dry running
Blocking protection In the state of a blocked impeller the starting attempts will be continued
indefinitely
Overload protection Integrated electronics automatically reduce motor speed when reaching
max. admissible motor temperature
Max. surface temperature approx. +90 °C (+194 °F)
Storage temperature -40 °C up to +120 °C (-40 °F up to +248 °F)
Lacqueur Motor casing powder-coated RAL 9005 black mat, pump housing unpainted Weight 1950 g (4.30 lbs)
Dimensions
L e i s t u n g s b e d a r f P u i s s a n c e a b s o r b ée
Capacity Q [U.S.GPM]
F ör d e r h öh e H a u t e u r m a n o m ét r i q u e
T o t a l h e a d
P o w e r c o n s u m p t i o n
H
[m] P
[kW]P1P
[HP]P1H
[feet]
0,1750.25 0.20 0.15 0.10 0.05 0
150 125 100 75 50
25
0 Every operating point can be reached within
the characteristic fields by tting different drive parameters.
The characteristic fields are applicable for the delivery of water of 20 °C (68 °F) temperature and an ambient temperature of 20 °C (68 °F).
The tolerance of total head and capacity is ±10%, performance tolerance is +10%. If the property of the pumped media differs, the characteristic fields change.
The power consumption P1 specifies the electrical power input.
Hydraulic specifications and power consumption