PDMS管道命名规则

更新时间:2023-07-26 10:19:05 阅读: 评论:0

PLEASE NOTE:
CADCentre has a policy of continuing product development:
therefore, the information contained in this document may be subject to change without notice.
CADCENTRE MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
While every effort has been made to verify the accuracy of this document, CADCentre shall not be liable for errors contained herein or direct, indirect, special, incidental or conquential damages in connection with the furnishing, performance or u of this material.
© Copyright 1994 CADCentre Ltd
All rights rerved. No part of this document may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwi, without prior written permission of CADCentre.
The software programs described in this document are confidential information and proprietary products of CADCentre Ltd or its licensors.
Inc
GmbH  CADCentre
CadCentre
LTD  CADCentre
Avenue
Richmond
Limespark  10700
High下开头的成语接龙
Cross
Im
7b Suite
感人情话
Otto-Volger-Stras
300
Road
Madingley
65843
OHB沐浴晨曦
Sulzbach/Taunus Houston Texas 77042
CB3
Cambridge
England Germany USA
Telephone: (0223) 314848 Telephone          06196  5052-0 Telephone      (713) 977 1225
International    (+44) 223 314848 International (+49) 6196 5052-0 International (+1)713 977 1225
FAX              (0223) 65737 FAX          (06196)  505222 FAX              (713) 977 1231
(+44) 223 65737        (+49) 6196 505222 (+1) 713 977 1231
Index
1.Naming Components
2. Deriving Bolt Names
冲出亚马逊观后感郁金香种球怎么种植3. COCO Table Coding
4. Component CATREF coding
1. Naming Components
International Standard: A  ANSI Standard (ANSI) B  British Standard (BS)
D  Deutsche Institut für Normung (DIN) I ISO
M  Manufacturers Standardisation Society (MSS) P  American Petroleum Institute (API) J  Japane Standards Standard
BS1560, ANSI B16.9, DIN 2050 etc. Type
PDMS GTYP ATTA, TEE, BEND, ELBO, REDU, FLAN, OLET, NOZZ CROSS, VALVE, INST etc. Rating
ANSI, BS, API, MSS 125#, 150#, 300#, 600#, 900#, 1500#, 2500#, 3000#, 6000#, 9000#  (#=lb/sq. in.)
DIN  (ND=Nenndruck) 10, 16, 25, 63, 100, 160, 250, 320, 400 Facing
ANSI,BS,API,MSS,DIN  ANSI,BS,API,MSS DIN RF Raid Face  TO Tongue  FE  Tongue  FF Flat Face  GR Groove  NU  Groove RTJ R ing Type Joint  MA Male  VS  Projection SCF S crewed Female  FE Female  RS  Recess SCM Screwed Male TUB Plain End BLF Blinded
BWD Buttweld End  LIN Lined Facing Size:
Nominal bore sizes in inches or mm  Typical Catalogue Names:
BARC200 = BS1640 BW CONC REDUCER AAEA200 = ANSI B16.9 BW ELBOW 90 DEG
AAFWBD0 = ANSI B16.5 WN FLANGE CLASS 300 RF DCZFBP0 = DIN 2633 FLANGED NOZZLE PN16RF DAVHBPR = DIN 3202 GLOBE VALVE PN16 RF
International Standard Standard number Rating
Facing
Size
Component Type
2. Bolting
Bolts are named according to the following convention
Flange Face:  Flange Rating:  Bore code: DIN ANSI  A  FF      A PN 125#  A        6 1/8"  B  RF      B PN 150#  B      8 1/4"  C  FE DIN2512 C  PN 250#  C    10 3/8"  D  NU DIN2512 D  PN 300#  D    15 1/2"  E        E PN 400#    E  20 3/4"  F  F PN 600#    F  25 1"  G  G PN 900#  G    32    1.1/4"  H  H PN 1500#  H    40    1.1/2"  J  J PN 2500#  J  50 2"  K  K PN 5000#  K    65    2.1/2"  L  L PN    2.5  L  80 3"  M    M PN    6  M    90    3.1/2"  N  N PN  10  N  100 4"  P  V13 DIN2513 P  PN  16  P 125 5"  Q  R13 DIN2513 Q  PN  25  Q    R  R PN  40  R  150 6"    S PN  63  S  175 7"    T PN 100
T  200 8"    U PN 160
早安的话U        V PN 250  V  250 10"    W PN 320  W  300 12"    X PN 400  X  350 14"    Y PN  75#  Y  400 16"    Z PN 10000#  Z  450 18"            1 500 20"            2 550 22"            3 600 24"            4 650 26"            5 700 28"            6 750 30"        7 800 32"        8 850 34"        9 900 36"
Bore size code
Flange Rating Flange Facing
Type  M=Machine Bolt  S=Stud Bolt
Standard  A=Ansi  D=DIN
3. COCO Table Coding
connection types are coded according to the following convention:
Each COCO is restricted to a maximum of 4 characters to define the connection. The following types are treated as standard connections and there meanings are described below:-
ALL Compatible with all items  SCF S crewed Female ATT Attachment    SCM  Screwed Male BWD Buttweld    CLOS  Clod end SWF  Female Socketwelding  SWM  Male Socketwelding TUB  Pipe or Tubing    OPEN  Open end VENT  Open to vent    DRAN  Drain connection
The following codes are ud to t the connection types of flanged items. Each character defines a different attribute of the appropriate connection type.
PDMS Type (char 1)    Facing (char 2)  Rating (char 3)  F  Flange facing (for Flanges, Valves etc.)  A    FF      A PN 125#  G  Gasket facing(To connect to flanges)  B    RF      B PN 150#  W  Wafer type component (Char 1 followed  C    FE DIN2512 C  PN 250#  by normal flange COCO)    D    NU DIN2512 D  PN 300#        E        E PN 400#          F      F PN 600#        G  G PN 900#        H  H PN 1500#        J  J PN 2500#        K  K PN 5000#        L  L PN    2.5        M  M PN    6        N  N PN  10        P  V13 DIN2513 P  PN  16        Q  R13 DIN2513 Q  PN  25        R  R PN  40            S PN  63          T PN 100
来姨妈可以吃药吗
U PN 160          V PN 250          W PN 320          X PN 400          Y PN  75#          Z PN 10000#
Rating
Facing
ISOGEN TYPE Normally unud
团队游戏室外
4. Component NAME codes
Each character of the component name can be lected from the appropriate tables. Character 3 defines the component type. Character 1 is derived from the international standard columns on page 4.
All other characters are derived from the component specific page as either direct information or reference to the tables.
Example: To find the name of a 100NB ANSI B 16.9 LR 90 degree BW elbow
Char 1 is lected from page 3 = A
Char 3 is lected from the type list on page 7 = E
Char 2 is then lected from page 15 = A
This gives the first 3 characters as AAE
Char 4 is lected from page 16 as Long Radius = A
The chart at the bottom of page 16 then points to the tables to be ud to get the rest of the characters Char 5 is lected from the facing table E1 or E2 page 53/54 = 2
Char 6 is lected from the pressure rating table D1 page 56 = 0
Char 7 is lected from D2 page 57 as Not specified = 0
Finally the bore sizes are lected from table N1. There are characters for both bore sizes so the final two characters are NN
This gives us a catalogue name of AAEA200NN