C-001 Living Quarter

更新时间:2023-07-25 04:02:57 阅读: 评论:0

NORSOK STANDARD LIVING QUARTERS AREA
C-001
女人脚底出汗是湿气Rev. 2, October 1997
Plea note that whilst every effort has been made to ensure the accuracy of the NORSOK standards neither OLF nor TBL or any of their members will assume liability for any u thereof.
CONTENTS
FOREWORD2 INTRODUCTION2
1 SCOPE3
2 NORMATIVE REFERENCES3
3 DEFINITIONS AND ABBREVIATIONS3
3.1 Definitions3
3.2 Abbreviations4
4 LIVING QUARTERS AREA4
5 LIVING QUARTERS AREA ROOM PROGRAMME5
表示声音6 ARRANGEMENT OF MAIN FACILITIES IN THE LIVING QUARTERS5
6.1 Cabin area5
红包含义
6.2 Recreation area7
6.3 Catering area8
6.4 Administration centre15
6.5 Central Control Room/Telecommunication Centre/Maritime Control Room16
6.6 Medical centre and emergency hospital17
6.7 Helicopter traffic centre18
6.8 Changing rooms18
6.9 Technical rooms19
电影《天火》6.10 Traffic areas19
7 ARRANGEMENT OF MAIN FACILITIES ADJACENT TO THE LIVING QUARTERS20
7.1 Helicopter deck20
7.2 Helicopter hangar21
7.3 Mustering area, lifeboat stations and safety equipment21
7.4 Workshops, laboratories, etc.21
7.5 External areas22
8 MISCELLANEOUS REQUIREMENTS22
8.1 Wet rooms22
8.2 Technical installations in walls, ceilings and decks23
8.3 Ceiling heights23
欧阳淳
8.4 Doors24
见贤思齐意思8.5 External maintenance access24
8.6 Artistic decoration24
8.7 Lighting24
8.8 Reverberation time25
8.9 Refu bins25
9 ROOM FINISHES SCHEDULE25 ANNEX A DATA SHEETS (NORMATIVE)26 ANNEX B LIST OF APPLICABLE ACTS AND REGULATIONS FOR THE NORWEGIAN CONTINENTAL SHELF (INFORMATIVE)27
FOREWORD
NORSOK (The competitive standing of the Norwegian offshore ctor) is the industry initiative to add
布莱德雷value, reduce cost and lead time and remove unnecessary activities in offshore field developments and operations.
The NORSOK standards are developed by the Norwegian petroleum industry as a part of the NORSOK initiative and are jointly issued by OLF (The Norwegian Oil Industry Association) and TBL (The Federation of Norwegian Engineering Industries). NORSOK standards are administered by NTS (Norwegian Technology Standards Institution).
The purpo of this industry standard is to replace the individual oil company specifications for u in existing and future petroleum industry developments, subject to the individual company's review and application.
The NORSOK standards make extensive references to international standards. Where relevant, the contents of this standard will be ud to provide input to the international standardization process. Subject to implementation into international standards, this NORSOK standard will be withdrawn. Annex A is normative. Annex B is informative.
INTRODUCTION
Main Changes from revision 1 to revision 2 are in summary:
•Partial implementation of the following guidelines from the Norwegian Petroleum Directorate: -Guidelines on Living Quarters to regulations relating to systematic follow-up of the working environment in the petroleum activities. (Published 8 March 1995).
-Guidelines on means of access, stairs, ladders etc. to regulations relating to systematic follow-up of the working environment in the petroleum activities. (Published 8 March 1995).•Various transfer of operational experience.
•Room finishes schedule in data sheet CDS-102 now allows for specifying dry/ wet and clean/ dirty room usage.
1SCOPE
This standard defines the basic requirements for the architectural design and engineering of the Living Quarters area on offshore installations in the petroleum activities. The requirements have emphasis on installations defined as being of a fixed type. For mobile installations additional requirements may be applicable. The standard specifies the minimum functional requirements to the LQ, and is meant to provide a tool, (the Living Quarters Area Room Programme), for systematic treatment of rooms/areas and related data.
The description of the main facilities in this standard shall be read in conjunction with NORSOK
C-002, Architectural components and equipment, where more detailed information is specified with respect to materials, finishes, furniture, equipment, etc.
Other discipline requirements related to this subject are covered in respective NORSOK standards. The activities and requirements shall be integrated with the architectural design development to achieve a co-ordinated and optimal solution for the Living Quarters area.
2NORMATIVE REFERENCES
The following standards include provisions which, through reference in this text, constitute provisions of this NORSOK standard. Latest issue of the references shall be ud unless otherwi agreed. Other recognized standards may be ud provided it can be shown that they meet or exceed the requirements of the standards referenced below.
NORSOK C-002Architectural components and equipment
NORSOK I-CR-004Control centre (will be I-004)
NORSOK S-DP-001Technical safety (will be S-001)
NORSOK S-DP-002Working Environment (will be S-002)
3DEFINITIONS AND ABBREVIATIONS
塑明3.1Definitions
Normative references Shall mean normative in the application of NORSOK standards. Informative references Shall mean informative in the application of NORSOK standards.
Shall Shall is an absolute requirement which shall be followed strictly in order
to conform with the standard.
Should Should is a recommendation. Alternative solutions having the same
functionality and quality are acceptable.
May May indicates a cour of action that is permissible within the limits of
the standard (a permission).
Can Can-requirements are conditional and indicates a possibility open to the