诺基亚操作指令(含参数说明)

更新时间:2023-07-23 21:24:37 阅读: 评论:0

ZEOL查询当前告警ZEOL:**;(**为BCF号)
ZEOH查询历史告警ZEOH:YYYY-MM-DD:
ZEEI查询无线配置(TRX)的状态ZEEI:SEG(或BCF,B
ZEEL查询TRX时隙闭锁状态ZEEL:BL;
ZERO:SEG(或BTS)=
ZERO查询时隙的信息,包括TSC(要与BCC一致
ZEQO查询BTS参数ZEQO:SEG=**:ALL;
ZEUO查询功率等级和功控参数ZEUO:SEG=**;
ZEHO查询切换参数,包括小区切换开关等ZEHO:SEG=**;
ZEAO查询邻区参数ZEAO:SEG=**;
ZEAC增加邻区EAC:SEG=12::LAC=14087,CI=9431,:NCC=3,BCC=2,FR ZEAD删除邻区EAD:SEG=12::LAC=14087,CI=9561;
ZEAM修改邻区参数EAM:SEG=12::LAC=14231,CI=6012,:NEWLAC=14233,N ZEAF添加TD邻区ZEAF:SEG=43::RNC
ZEAK修改TD邻区
ZEAL查询TD邻区
ZEEO看基站控制参数(不常用)
ZEAT同频同BSIC查询ZEAT;
ZEEO查询BSC级参数ZEEO:ALL
ZEHG:SEG=32:EFP=
ZEHG修改切换参数,快速平均切换、快速平均
ZEFS重启BCF的命令ZEFS:**:L;ZEFS后直接跟BCF号
ZEQS启站和闭站的命令ZEQS:BTS=**:L:FH
ZEQE:修改跳频ZEQE:BTS=**:HOP=N;先用ZEQS闭站后才可执行ZEQE:修改NCC,BCC,LAC,CI等,需要闭站ZEQE:SEG=12:CI=4087,NCC=3,BCC=4,LAC=14087,MCC ZDTC切换BCCH载频ZDTC:T0298:BL;(先闭主频信令,再开要切换到的载ZDTC激活载频信令ZDTC:T1663:WO;(T表示载频,166是BCF号,3是第3块ZDSB查询信令链路带宽ZDSB:::PCM=349(ET-PCM号),查询载频信令名
ZDTI看BCF和TRX信令是否激活ZDTI;ZDTI:::PCM=346;
ZERS重启载频,如果有开跳频,先闭BTS ZERS:BTS=**,TRX=
ZERM修改频点(需要先闭载频)ZERM:BTS=**,TRX=*:FREQ=*;
ZERM开半速率(需要先闭载频)ZERM:BTS=**,TRX=*:CH0=SDCCH,CH1=TCHD,CH2=TCHD ZERM关半速率(需要先闭载频)ZERM:BTS=**,TRX=*:CH0=SDCCH,CH1=TCHF,CH2=TCHF ZERM改变时隙类型ZERM:BTS=**:TRX=**:CH0=SDCCH
ZEQM调整半速率门限,FRL≤FRU,否则无效Z EQM:SEG=185:FRL
ZEUG调整功率ZEUG:SEG=**:PMAX
ZEQV控制GPRS的开关GENA ZEQV:SEG=**,GENA=N;ZEQV:BTS=133:CDEF=50;重新ZERM开载频的GPRS功能,需要先闭载频。ZERM:BTS=108,TRX
ZERS闭TRX,CH ZERS:BTS=**,TRX=**:CH=**:U
ZERD删除TRX
网页维护ZEQM ZEQM:SEG=186:::PI=Y,REO=8,PET=640;PET=640表示反向的
ZEQM ZEQM:SEG=186:::PI=Y,REO=8;PET不填默认为20,正向,虚拟的增加8DB,使用户尽ZEUS修改电平门限LUR,LUP等
ZEUQ修改质量门限
ZEUS电平功控ZEUS:SEG=34:UDR=-75,UDP=2,UDN=3,LDR=-85,LDP=1 ZEUQ质量功控ZEUQ:SEG=34:LDR=4,LDP=1,LDN=2,UDR=1,UDP=1,UDN ZEHS电平切换ZEHS:SEG=34:LDR=-90,LDP=2,LDN=3,LUR=-100,LUP= ZEHQ质量切换ZEHQ:SEG=34:QDR=5,QDP=2,QDN=3,QUR=5,QUP=2,QUN ZESI查询DAP占用的时隙数ZESI:ID=**;(**为
ZWQO说明:查BSC软件版本可由命令:ZWQO:CR; (看最后"DEF"为 Y的那一行,SA5801C 表ZEFR重启OMU,可重启BB退服载频EFR:110:OMU;110
ZFWO大容量新BSC要用ZFXO看NSEI状态。通过时,先关GEN ZFXO
UBS TRX loop test
ZEGO 看计时器,定时器,timmer ZIGO 查看BSC历史执行指令ZIGO;ZMVF 进入MSC 后再查看ZMVF:NEG=N:LAC=**;ZMII 进入HLR 后再查看HLR 用户数ZMII ;ZMVI 进入MSC 后再查看VLR 用户数ZMVI ;ZAHO BSC 级当前的告警,包括Tranccoder 、BSC ZAHO ;ZAHP BSC级别的历史告警
ZEQF
修改PLMN接入参数,如直接重试功能等Z EQF:SEG=610:DR=
ZEQJ 修改PER、AG(寻呼块)、MFR(寻呼次数)ZEQJ:SEG=610:AG=2,MFR=5,PE
R=3;ZEQM 修改TRP,手机PMAX1,DTX,半速率开关NE ZEQM:SEG=610:PMA ZEQM 修改分集接收开关RDIV要用BTS。ZEQM:BTS=186:RDVIV=Y;ZEQG 修改参数DIRE,使DIRE(SEG级)值高于NB ZEQG:SEG=2,DI RE=1;ZEQG 修改RLT,RXP,HYS,DIRE,RRH等
ZEQG:SEG=610:HYS=14,RXP=-98,RLT=64,DIRE=1;ZEQM
修改参数LSEG,使语音业务优先占用非E ZEQM:BTS=2,LS EG=100;
ZEQM 修改FRL,FRU门限值(20,40,剩余的T  EQM:SEG=185:FRL
ZEQV GPRS ENABLED, EGPRS ENABLED, ROUTING AREA CODE(RAC), DEDICATED GPRS CAPACITY(ZEQV 控制GPRS的开关GENA,也可修改RAC等,然ZEQV:SEG=**,GENA ZERM 开载频的GPRS功能。需要先闭载频。ERM:BTS=108,TRX=ZACA 清除告警ZACA:告警号ZEOR 清除BCF告警ZEOR:BCF号:告警ZQRL 进BSC查看BSC连接的IP地址ZQRL;ZQNI 查看BSC的C-NUM(配置CRT的BSC机器码时ZQNI;ZTPI 看测量是否打开(GSM)TPI:MEASUR,DAC;ZTPS 开启测量
ZTPE 关闭一个测量ZTPM 修改测量
ZWOI 查看BSC测量开关状态等(GPRS)ZWOI;ZWOI:10;ZWOS 查看BSC的FEATURES状态
ZUSC ZUSC:BCSU,BCSU号:SP;完成倒换(ZUSC:BCSU倒换ZUSI ZUSI:BCSU;查看BCSU倒换后的状态ZNCI 查看BSC所属的MSC ZNCI;ZCEL ZCEL:CGR=1&2&3;(大容量有2,3,查看A口负荷:每线话务ZOLT 查瞬时A口信令负荷,安全门限0.2,临界ZOLT;ZIAG
修改BSC密码,直接分号回车输入老密码Z IAG;
ZWTI:P:BCSU,0:;查看PCU屮位ZW7I 查看ETRX容量ZW7I:FEA,FULL:FSTATE=ON,FEA=4;ZW7I 查看已用的ETRX数量ZW7I:UCAP,FULL:FEA=4;
ZW7I 查看PCU数量ZW7I:UCAP,FULL:F
ZFUI;看查BSC下PCU数目(BEARER NAME)和各条GB容量(红色字体),整个BSC的GB容量就是把各条
ZFXI
Gb Link负荷检查 Gb Link (NS-VC)的Operating state可以用 ZFWO 命令来查看,一个NSEI对应一条Gb链路PCU PCU规划应满足每个PCU下不超过64个小区,128块载频,256个时隙ZEBO ZEBO:35;(35为IDLE号)
ZEBP ZEBP;查看BSC下全部SEG小区名及NSEI ZEBQ 指定ACT为ADJ或者为IDLE ZEBD 删除IDLE表ZEBC 新建IDLE表
ZEEG
ZEEG:ACT;交换主备用BFREQ、BTSC、BFRT、BLEV、BDAL等。
ZDTC:NAME:AD(OR WO)倒换BCCH的信令,NAME为ZDSB命令中所得的传输名,AD为ZW7I LICENCE、FEATURE、USED CAPACITY RE 可以看AMR ZEWO 查看BTS软件版本ZDMF
查看信令负荷180万ZWQO
说明:查BSC软件版本可由命令:
tasaki是什么牌子ZWQO:CR; (看最后"DEF"为 Y的那一行,SA5801C 表
ZEFO 查看T200
ZEBO
查看l ist 一般收测量添加频点在这里面看看出
卡通手机图片
重建DAP
1、ZEQS:BTS=107:L:FHO;
2、ZEQV:BTS=107:EGENA=N;
3、ZERS:BTS=107,ZERS:BTS=107,TRX=2:L;ZERM:BTS=107,TRX=1:DAP=N;ZERM:BTS=107,TRX=2:DAP=N;
4、ZESG:ID=15; /* 删除DAP */
5、ZESE:ID=15,CR
6、ZERM:BTS=107,TRX=1:DAP=15;ZERM:BTS=107,TRX=2:DAP=15;
ZERS:BTS=107,TRX=1:U;ZERS:BTS=107,TRX=2:U;7、ZEQV:BTS=107:EGENA=Y;8、ZEQS:BTS=107:U;)
ZIAI:USERID:COM;BSC权限
ZIAT BSC权限
GPRS下行功控
在BSC侧操作命令如下:
1、功能开启:ZEQV:SEG=<g_id>:DLPC=Y;
2、修改“DL PC C/I Target”和“DL PC PSK8 BEP Target”:
ZEEM::PCCI=xx,PCPSK=xx;
3、修改“DL PC Window Size”和“DL PC Default Power Reduction”:ZEUM:PCWS=xx,PCPOW=xx;
查看TD邻区创建TD邻区
ZEAL ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=56191:LAC=24581,SAC=1,FREQ=10055,CPA=1, ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=56192:LAC=24581,SAC=1,FREQ=10063,CPA=1,
ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=56193:LAC=24581,SAC=1,FREQ=10071,CPA=1,
ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=57161:LAC=24581,SAC=1,FREQ=10080,CPA=1,
ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=57162:LAC=24581,SAC=1,FREQ=10088,CPA=1,
ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=57163:LAC=24581,SAC=1,FREQ=10104,CPA=1,
ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=58821:LAC=24581,SAC=1,FREQ=10112,CPA=1,
ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=58822:LAC=24581,SAC=1,FREQ=10120,CPA=1,
ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=55531:LAC=24581,SAC=1,FREQ=9437,CPA=1,D
ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=55532:LAC=24581,SAC=1,FREQ=9445,CPA=1,D
ZEAF:SEG=542::MCC=460,MNC=00,RNC=1,CI=55533:LAC=24581,SAC=1,FREQ=9455,CPA=1,D
MCPA站点
BSC1D1 BCF-0431 BTS-0431 PROCES 2013-09-23 10:53:58.71
** ALARM TRX -013 SUNINGGC1
(43043) 7607 TRX OPERATION DEGRADED
TRX object allocation failed in RF module
01 00 00 84 22 00
前面两位如果是 ”01“ 代表 RRU掉链;如果是”00“代表RRU掉电;如果是”04“代表RRU无响应。
中间 ”84“后面的两位,这里是”22“,代表第二个光口的第二台RRU
TRS BCF级参数”TRS2”管理基站能使用的传输数量,默认值为0,即能支持两条传输。在TRS
ZEFO:BCF:ALL;
ZEFM:BCF:::TRS2=1;
需要将TRS2修改为1ADDITIONAL 2 E1/T1 IF ........(TRS2).. 1 (IN USE)
<HIST> BSC1812      BCF-0359            COMM      2014-10-31  21:26:22.75
... CANCEL
TRE -0001
(23360) 8274 LICENCE FOR 2G FLEXI ADDITIONAL 2 E1/T1 IS NOT AVAILABLE
Flexi EDGE BTS      2G Flexi TRS        Alarm dba
02 4080d 00 4d
:**;(**为BCF号)ZEOL
ZEOH::BCF=**;当日历史告警ZEOH
虎皮尖椒酿肉ZEEI::BCSU; 查看BCSU的容量,2i最大512,3i最大880,FLEXI最大1600。ZERM
ZEQM
ZEAC
:SEG(或BTS)=**;ZEAD
:SEG=**:ALL;ZEQV
ZEFS
ZEQS
ZERS
SEG=12::LAC=14087,CI=9431,:NCC=3,BCC=2,FREQ=54:PMRG=5,DRT=-80,SL=-95ZEUG
绘本简笔画
SEG=12::LAC=14087,CI=9561;ZEQG
SEG=12::LAC=14231,CI=6012,:NEWLAC=14233,NEWCI=6016:SYNC=N,POPT=;
ZEQM:SEG=47:::QSRI=8,QSRP=8,FDD=-12;ZEQE
ZERO:BTS=**可以查看DAP ID :EFP=Y,EFH=Y,ZESI:ID=**;  可以查看DAP ID=209 ZEFS:**:U;
ZEQS:BTS=**:U;
:BTS=**:HOP=N;先用ZEQS闭站后才可执行青城山住宿
:SEG=12:CI=4087,NCC=3,BCC=4,LAC=14087,MCC=460,MNC=00;ZEQE  改CI同BSC同LAC才可以更换CI BL;(先闭主频信令,再开要切换到的载频,最后激活主频信令)
:T1663:WO;(T表示载频,166是BCF号,3是第3块载频)
:::PCM=349(ET-PCM号),查询载频信令名
;ZDTI:::PCM=346;
ZERS:BTS=**,TRX=**:U;
:BTS=**,TRX=*:FREQ=*;
:BTS=**,TRX=*:CH0=SDCCH,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD;
:BTS=**,TRX=*:CH0=SDCCH,CH1=TCHF,CH2=TCHF,CH3=TCHF,CH4=TCHF,CH5=TCHF,CH6=TCHF,CH7=TCHF;
:BTS=**:TRX=**:CH0=SDCCH
:SEG=185:FRL=100,FRU=100;
需要降多少PMAX1/2就是多少,初始为0,表示满功率。ZEUG:SEG=25:INC=4,RED=2,INT=1
:SEG=**,GENA=N;ZEQV:BTS=133:CDEF=50;重新打开GENA时要注意非EDGE小区加上NSEI,否则NSEI将被系统自动分配开数据载频
:BTS=**,TRX=**:CH=**:U
慎用
640表示反向的,相当于虚拟减少8DB,使用户占用别的小区
不填默认为20,正向,虚拟的增加8DB,使用户尽量占用该小区
:SEG=34:UDR=-75,UDP=2,UDN=3,LDR=-85,LDP=1,LDN=1,UUR=-85,UUP=2,UUN=3,LUR=-96,LUP=1,LUN=1;
:SEG=34:LDR=4,LDP=1,LDN=2,UDR=1,UDP=1,UDN=2,LUR=4,LUP=1,LUN=2,UUR=1,UUP=1,UUN=2;
:SEG=34:LDR=-90,LDP=2,LDN=3,LUR=-100,LUP=1,LUN=2;
:SEG=34:QDR=5,QDP=2,QDN=3,QUR=5,QUP=2,QUN=3;
ZESM:ID=**,NFT=,NLT=;ZESM:ID=**,PSEI=**;修改动态池对应的时隙
:CR; (看最后"DEF"为 Y的那一行,SA5801C 表示S10.5,如果是SB5###则为S11.5….,SC00500N表示S?)不用
手抓饼皮的做法ZFWO:BCSU=0&&6;
:NEG=N:LAC=**;
ZEQF:SEG=114:PLMN=0&&7(切换时只切换到NCC=PLMN定义范围内的小区);
:SEG=610:PMAX1=29,RET=4,NY1=10,SLO=7,BLT=85,DTX=1,BMA=1;
:SEG=610:HYS=14,RXP=-98,RLT=64,DIRE=1;
:SEG=185:FRL=100,FRU=100;
AREA CODE(RAC), DEDICATED GPRS CAPACITY(CDEF),
:SEG=**,GENA=N;ZEQV:BTS=133:CDEF=50;重新打开GENA时要注意非EDGE小区加上NSEI,否则NSEI将被系统自动分配
BTS=108,TRX=3:GTRX=Y;
慎用
慎用
MEASUR,DAC;
红烧大鸡腿
BCSU倒换后的状态
负荷:每线话务量要小于0.8,计算方法:BSC话务量/BSC电路数
:FEA,FULL:FSTATE=ON,FEA=4;
:UCAP,FULL:FEA=4;
ZW7I:FEA,FULL:FSTATE=ON;(new)
B容量(红色字体),整个BSC的GB容量就是把各条GB容量求和
用 ZFWO 命令来查看,一个NSEI对应一条Gb链路,2iBSC一个BSCU只能带一个PCU,一个PCU对应一个NSEI,3iBSC有6个BCSU,一个,128块载频,256个时隙
、BLEV、BDAL等。

本文发布于:2023-07-23 21:24:37,感谢您对本站的认可!