报错信息:
Time Level Message Service Number Count Message ID Switch
星期四 四月 03 2014 03:07:00 GMT+00:00 Information Switch status changed from MARGINAL to HEALTHY. Switch 8142 1 FW-1425 swd78_02
星期四 四月 03 2014 03:06:42 GMT+00:00 Warning Switch status changed from HEALTHY to MARGINAL. Switch 8140 1 FW-1424 swd78_02
星期四 四月 03 2014 03:06:42 GMT+00:00 Warning Switch status change contributing factor Marginal ports: 1 marginal ports. (Port(s) 15(0xf)) Switch 8141 1 FW-1436 swd78_02
星期四 四月 03 2014 03:06:07 GMT+00:00 Information The last fabric change happened at: Thu Apr 3 03:06:03 2014 Switch 8139 1 SNMP-1007 swd78_02
星期四 四月 03 2014 03:06:02 GMT+00:00 Warning Port (ID: 15) QOS is disabled Switch 8138 1 PORT-1010 swd78_02
星期四 四月 03 2014 01:17:15 GMT+00:00 Information The last fabric change happened at: Thu Apr 3 01:17:09 2014 Switch 8137 1 SNMP-1007 swd78_02
-----------------------------------------------------------------
swd78_02:admin> porterrshow
frames enc crc天上王城 too too bad enc disc link loss loss frjt fbsy
tx rx in err shrt long eof out c3 fail sync sig
=====================================================================
0: 2.3g 1.4g 0 0 0 0 0 19 32 0 3 6 0 0
1: 66 68 0 0 0 0 0 13 0 0 21 24 0 0
2: 49m 66m 0 0 0 0 0 0 4 0 3 6 0 0
3: 1.6m 821k 0 0 0 0 0 25 0 0 10 13 0 0
4: 1.2g 1.8g 0 0 0 0 0 0 27 0 3 6 0 0
5: 49m 15m 0 0 0 0 0 0 0 0 5 8 0 0
6: 277m 2.0g 0 0 0 0 0 0 0 0 3 6 0 0
7: 1.0m 540k 0 0 0 0 0 19 0 0 6 9 0 0
8: 267m 257m 0 0 0 0 0 10 0 0 2 4 0 0
9: 2.0g 2.0g 0 0 0 0 0 0 0 0 6 8 0 0
10: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
感动的文章 11: 3.4g 1.5g 0 0 0 0 0 0 18 0 1 2 0 0
12: 19m 230m 0 0 0 0 0 0 0 0 2 4 0 0
13: 3.5m 1.3m 0 0 0 0 0 0 0 0 3 5 0 0
14: 2.6g 1.3g 0 0 0 0 0 8 11 0 6 8 0 0
15: 3.8g 1.0g 47 7 0 0 0 1.4m 2 8 38 58 0 0
swd78_02:admin> portshow 15
portName:
portHealth: HEALTHY
芭比娃娃怎么做Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags: 0x1000490b PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE LOGIN LED
portType: 11.0
POD Port: Port is licend
portState: 1 Online
青海玉树portPhys: 6 In_Sync
portScn: 16 E_Port
port generation number: 74
罗帏portId: 660f00鸭肉煲汤放什么材料好
portIfId: 4302000f
portWwn: 20:0f:00:05:1e:7b:e7:bf
portWwn of device(s) connected:
Distance: normal
portSpeed: N1Gbps
LE domain: 0
FC Fastwrite: OFF
Interrupts: 1724 Link_failure: 8 Frjt: 0
Unknown: 0 Loss_of_sync: 38 Fbsy: 0
Lli: 1682 Loss_of_sig: 58
Proc_rqrd: 3153170 Protocol_err: 0
Timed_out: 0 Invalid_word: 1448546
Rx_flushed: 0 Invalid_crc: 7
Tx_unavail: 0 Delim_err: 0
Free_buffer: 0 Address_err: 0
Overrun: 0 Lr_in: 36
大洲岛Suspended: 0 Lr_out: 15
Parity_err: 0 Ols_in: 15
2_parity_err: 0 Ols_out: 18
CMI_bus_err: 0
Brocade Switches – 如何确定是SFP 或是光纤线导致“Loss of Link(丢失链接)”问题
问题描述:
一个有问题的SFP或光纤线会造成丢失与主机,存储或另一台交换机的连接问题,在交换机的error log中可能有如下显示:
2007/12/06-23:50:56, [FW-1424], 7682,, WARNING, SWITCH_1, Switch status changed from HEALTHY to MARGINAL
2007/12/06-23:50:56, [FW-1436], 7683,, WARNING, SWITCH_1, Switch status change c
ontributing factor Marginal ports: 1 marginal ports. (Port(s) x )
问题解决方法:
首先确定是由于SFP还是光纤线的问题造成链接丢失,执行下面的命令:
检查porterrshow命令的输出:
如果仅是"enc out "单独报错主要是因为光纤线的问题。
如果是"enc out夜总 "和"crc err "组合报错主要是GBIC/SFP的问题。
要确定是源端还是目标端SFP报错,需要再检查"portshow x" 的输出(x代表有问题端口号)