Commission communication in the framework of the implementation of: Commission Regulation (EC) No 244/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for non- directional houhold lamps, amended by Commission Regulation (EC) No 859/2009 of 18 September 2009 as regards the ecodesign requirements on ultraviolet radiation of non-
传世名字
directional houhold lamps
and
Commission Delegated Regulation (EU) No 874/2012 of 12 July 2012 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of
electrical lamps and luminaires
and
Commission Regulation (EU) No 1194/2012 of 12 December 2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for directional lamps, light emitting diode lamps and related equipment (Publication of titles and references
of transitional methods of measurement (1) for the implementation of Commission Regulation (EC) No 244/2009 amended by Commission Regulation (EC) No 859/2009, Commission Delegated Regulation (EU) No 874/2012, and Commission Regulation (EU) No 1194/2012)妈妈睡了
(Text with EEA relevance)
(2014/C 22/02)
For the purpos of verification of compliance with the requirements of Commission Regulation (EC) No 244/2009 amended by Commission Regulation (EC) No 859/2009, Commission Delegated Regulation (EU) No 874/2012, and Commission Regulation (EU) No 1194/2012 the following measurement procedures shall be ud if:
— no other measurement procedures are specified in harmonid standards of which the reference numbers have been published for that purpo in the Official Journal of the European Union, (particularly, most of the mentioned EN standards are also ISO standards)
— or no other specific measurement procedures for verification of compliance are referenced in the afore mentioned Regulations.有爱
伤心短句
夏末秋至
The definitions of'directional lamps' and'non-directional lamps' in Article 2 of Commission Regulation (EU) No 1194/2012 shall apply.
1. In ca no specific documents have been referenced for measured parameters, reliable, accurate and
reproducible measurement procedures, which take into account generally recognid state-of-the-art measurement methods, shall be ud. This includes but is not limited to the number of switching cycles, the rated lifetime for LEDs, and the premature failure rate of LEDs.
仓库保管员
2. Photometric parameters shall be measured according to prEN 13032-4 for LED lamps and modules
(including colourimetric parameters), and EN 13032-1 for all other types.
3. For non-directional lamps tests shall be carried out as follows:
a. Incandescent light bulbs shall be measured according to methods t out in the following documents:
马克思主义哲学
(1) It is intended that the transitional methods will ultimately be replaced by harmonid standards. When available,
reference(s) to the harmonid standards will be published in the Official Journal of the European Union in accordance with Articles 9 and 10 of Directive 2009/125/EC.
Non-directional incandescent light bulbs
b. Halogen incandescent light bulbs shall be measured according to methods t out in the following
documents:
Non-directional halogen incandescent light bulbs
Non-directional halogen incandescent light bulbs
c. Compact fluorescent lamps with integrated control gear shall be measured according to methods t
out in the following documents:
Non-directional compact fluorescent lamps
d. Light emitting diode lamps shall be measured according to methods t out in the following docu
ments:
Non-directional light emitting diode lamp
e. Light emitting diode modules shall be measured according to methods t out in the following老师办公室
documents: