编号: |
检查项目:设备系统电源及风扇检查 |
检查命令: CISCO#show environment status/all |
检查期待结果:电源及风扇运行正常 |
备注:对于思科的交换机与路由器命令可能会不大相同,此外命令show power还能看到电源的冗余状态(对于有两个或两个以上电源的设备),电源冗余状态有两种模式: redundant(冗余)与combined(组合)。根据用户实际网络环境与设备负载模块的数量决定电源模式。 |
检查范例:(由于现实内容过多,这里只截取部分) ksy_c6509_2#show environment status fan-tray 1: fan-tray 1 type: WS-C6509-E-FAN fan-tray 1 mode: Restricted-power fan-tray 1 fan-fail: OK power-supply 1: power-supply 1 fan-fail: OK power-supply 1 power-input: AC high power-supply 1 power-output-mode: high power-supply 1 power-output-fail: OK |
检查结果:□正常 □不正常 |
淘宝新规 |
编号: |
检查项目:设备运行检查 |
检查命令:CISCO#show environment status |
检查期待结果: 设备内部各部分工作温度小于45摄氏度 |
检查范例:(由于现实内容过多,这里只截取部分) ksy_c6509_2#show environment temperature all VTT 1 outlet temperature: 28C VTT 2 outlet temperature: 30C VTT 3 outlet temperature: 26C |
检查结果:□正常 □不正常 |
编号: |
检查项目:设备IOS软件版本及运行时间 |
检查命令:cisco#show version |
备注:主要显示IOS的版本、路由器持续运行的时间约、路由器主存的大小、共享存储器的大小、闪存的大小、IOS映像的文件名。Display version命令显示了路由器的许多非常有用的信息 |
检查标准:-软件版本为Version 12.电视面板XXX(大概值)是正常,否则不正常 -重启方式为power-on为正常,Uptime小于1天时认为不正常 -Configuration register值不为0XF时认为不正常 |
Cisco IOS Software, C3560 Software (C3560-IPSERVICES-M), Version 12.2(25)SEE2, RELEASE SOFTWARE (fc1) Copyright (c) 1986-2006 by Cisco Systems, Inc. Compiled Fri 28-Jul-06 07:19 by yenanh Image text-ba: 0x00003000, data-ba: 0x0109B370 ROM: Bootstrap program is C3560 boot loader BOOTLDR: C3560 Boot Loader (C3560-HBOOT-M) Version 12.2(25r)SEC, RELEASE SOFTWARE (fc4) GDGZ-PA-CMNET-SW03-3560 uptime is 1 year, 16 weeks, 1 day, 16 hours, 59 minutes System returned to ROM by power-on System restarted at 16:52:46 CST Mon Mar 12 2007 System image file is "flash:c3560-iprvices-mz.122-25.SEE2/c3560-iprvices-mz.122-25.SEE2.bin" cisco WS-C3560-48TS (PowerPC405) processor (revision D0) with 118784K/12280K bytes of memory. Processor board ID CAT1044RHNY Last ret from power-on 3 Virtual Ethernet interfaces 48 FastEthernet interfaces 4 Gigabit Ethernet interfaces 荧光微球The password-recovery mechanism is enabled. 512K bytes of flash-simulated non-volatile configuration memory. Ba ethernet MAC Address : 00:19:E8:68:7E:80雪中悍刀行语录 Motherboard asmbly number : 73-9898-06 Power supply part number : 341-0097-02 Motherboard rial number : CAT10435P2A Power supply rial number : DCA103982EF Model revision number : D0 Motherboard revision number : A0 Model number : WS-C3560-48TS-E System rial number : CAT1044RHNY SFP Module asmbly part number : 73-7757-03 SFP Module revision Number : A0 SFP Module rial number : CAT10415GGQ Top Asmbly Part Number : 800-26385-02 Top Asmbly Revision Number : C0 Version ID : V02 CLEI Code Number : COMMK00ARB Hardware Board Revision Number : 0x01 Switch Ports Model SW Version SW Image ------ ----- ----- ---------- ---------- * 1 52 WS-C3560-48TS 12.2(25)SEE2 C3560-IPSERVICES-M Configuration register is 0xF |