Battery Expiration is no longer cau for replacement on Storage 6x80 and 25x0 Arrays. [ID 1171913.1]
修改时间 13-MAR-2012    类型 FAB    状态 PUBLISHED
In this Document
Symptoms
Cau
Solution
References
Applies to:
Sun Storage 2540 Array - Version: Not Applicable to Not Applicable - Relea: N/A to N/A Sun Storage 6580 Array - Version: Not Applicable to Not Applicable  [Relea: N/A to N/A] Sun Storage 6780 Array - Version: Not Applicable to Not Applicable  [Relea: N/A to N/A] Sun Storage 6180 Array - Version: Not
Applicable to Not Applicable  [Relea: N/A to N/A] Sun Storage 2510 Array - Version: Not Applicable to Not Applicable  [Relea: N/A to N/A] Information in this document applies to any platform.
This issue also affects the 2540 Array.
__________
Affected Parts: (FRU/CRU Part Number / Description)
371-4676 - Battery Pack, Sun Storage 6180
371-4374 - Battery Backup Module, Sun Storage 6580/6780
371-2482 - 2.5V 6.5Ah 400mA Li-Ion Battery Module, Sun StorageTek 2510/2530/2540  Symptoms
Subsystems may report the following critical faults, which indicate failure due to the battery timer:
Reference
CAM bad faults(alarms)
xx.66.1039  Battery Nearing Expiration
xx.66.1005  Controller Cache Backup Battery Nearing Expiration    xx.66.1254  Battery has Expired
xx.66.1255  Battery has Expired
SANtricity bad faults(in recovery guru)
可口可乐商标REC_NON_FRU_BATTERY_NEAR_EXPIRATION = 39
REC_BATTERY_NEAR_EXPIRATION = 5
REC_EXPIRED_BATTERY = 254
REC_EXPIRED_INTEGRATED_BATTERY = 255
Any 2510, 2530, or 2540 subsystem that receives the following fault will require further investigation, as the SMART technology is not in u until the firmware is at or later:
Impact
Customers using the the above mentioned arrays will no longer receive replacement batteries that have been determined by the subsystem as failed or about to fail due to the battery age timer. The customer will receive instructions on how to ret the timer if it is still active on the affected system.
Cau
Root Cau
The affected arrays u SMART Battery Backup Units(BBU). The SMART BBU will monitor
its current charge level, and if this cannot be maintained through a charge cycle, write caching will be disabled. The smart BBU will also monitor its Full Charge Capacity, which is expected to decrea over the life of the battery. Once this Full Charge Capacity falls below the Replacement Capacity threshold (which should be a value greater than the Minimum Application Capacity), the battery is nearing the end of its uful life and should be replaced. At this point, Battery Replacement Required event notification occurs, which is signified by the following Critical Fault:
CAM:  xx.66.1176 Battery {0} has a full charge capacity below the replacement capacity threshold
SANtricity:  BATTERY REPLACEMENT REQUIRED = 176
Write Caching will NOT be disabled at this point. If the battery is not replaced, at some point the Full Charge Capacity will fall below the Minimum Application Capacity, at which point caching will be disabled and an informational event will be logged in the major event log with the following critical fault:
CAM: xx.66.1006  A battery has failed
xx.66.1040  A controller cache backup battery has failed
SANtricity:
REC_FAILED_BATTERY = 6, REC_NON_FRU_FAILED_BATTERY = 40
Solution
Workaround
Identify the critical faults:
After identifying the critical fault, apply the appropriate workaround as shown below:
1. If the Critical Fault listed is as follows, then ret the battery age:
CAM:
xx.66.1039    Battery Nearing Expiration
xx.66.1005    Controller Cache Backup Battery Nearing Expiration SANtricity:
REC_NON_FRU_BATTERY_NEAR_EXPIRATION = 39,
2. If the Critical fault listed is as follows, physically reat the battery and ret its age:
CAM:
xx.66.1254  -  Battery has Expired
xx.66.1255    Battery has Expired人流后多久能洗头
SANtricity:
REC_EXPIRED_BATTERY = 254, REC_EXPIRED_INTEGRATED_BATTERY = 255
3. If the array is a 2500 with firmware 06.17 or 06.70, and the Critical Fault listed is:
xx.66.1006    A battery has failed or REC_FAILED_BATTERY = 6
xx.66.1040    A battery has failed or REC_NON_FRU_FAILED_BATTERY = 4
To check the battery age:
# sscs list -d myarray -t Battery fru Tray.85.Battery.A
Element Name        : Tray.85.Battery.A
Element Status      : Optimal
合并同类项Enabled State      : Enabled
FRU Number          : 1T71200441PS
FRU Type            : Battery
Firmware            : N/A
Id                  : SUN.371-2482-01.1T71200441PS
IdentifyingNumber  : 1T71200441PS
*Life Remaining      : 288 Days*
ManufactureDate    : Wed Feb 28 19:00:00 EST 2007
Model              : 371-2482-01中华精神
If the battery life remaining is zero(0), physically reat the battery and ret its age. If the life remaining is greater than zero(0), then the battery should be replaced.
4. If the array is a 6x80 or a 2500 with firmware 7.3
5.10.10 or later, and the Critical fault listed is as follows, the battery should be replaced:
CAM:
xx.66.1006    A battery has failed
xx.66.1040    A controller cache backup battery has failed
xx.66.1176    Battery {0} has a full charge capacity below the replacement capacity threshold
SANtricity:
REC_FAILED_BATTERY = 6, REC_NON_FRU_FAILED_BATTERY = 40
BATTERY REPLACEMENT REQUIRED = 176
Resolution
For the Sun Storage 6180/6580/6780 have the battery timer disabled after upgrading to 7.77 firmware or later.
For the Sun Storage 2510/2530/2540 you can have the battery disabled by editing the NVSRAM per document 1021054.1. No new NVSRAM will be relead for this line.
The Sun Storage 2530-M2/2540-M2 has the battery timer disabled with GA relea firmware. No changes required.
Plea supply the following document to customers inquiring on SMART batteries:
Doc ID 1207186.1: SMART Battery Functionality in 2500 and 6000 Arrays,
and have them review the following document on how we are determining whether a battery is faulty or not:
Doc ID 1021054.1: Troubleshooting Storage Array Battery Faults.
If a customer wants a replacement battery that has expired but not failed, they can purcha one through sales.
稗史
References
For information about FAB documents, its relea process, implementation strategies and billing information, go to the following URL:
* /fab
In addition to the above you may email:
**************************
References
FAB > Standard > Reactive
相关内容
产品
∙Sun Microsystems > Storage - Disk > Modular Disk - 2xxx Arrays > Sun Storage 2540 Array
∙Sun Microsystems > Storage - Disk > Modular Disk - 6xxx Arrays > Sun Storage 6580 Array
∙Sun Microsystems > Storage - Disk > Modular Disk - 6xxx Arrays > Sun Storage 6780 Array
∙Sun Microsystems > Storage - Disk > Modular Disk - 6xxx Arrays > Sun Storage 6180 Array
散打是什么
∙Sun Microsystems > Storage - Disk > Modular Disk - 2xxx Arrays > Sun Storage 2510 Array
∙Sun Microsystems > Storage - Disk > Modular Disk - 2xxx Arrays > Sun Storage 2530 Array
关键字
ARRAY; BATTERY; CACHE; EX PIRATION; FIRMWARE; SANTRICITY; STORAGE 返回页首
为此文档评级
注释
文章评级
北京汽车摇号查询仅浏览
非常简单
胯下之辱有些简单
不简单

本文发布于:2023-06-25 17:26:37,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/82/1037798.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:评级   汽车   时间
相关文章
留言与评论(共有 0 条评论)
   
验证码:
推荐文章
排行榜
Copyright ©2019-2022 Comsenz Inc.Powered by © 专利检索| 网站地图