美国药典旋光度

更新时间:2023-06-17 12:28:19 阅读: 评论:0

781 OPTICAL ROTATION 旋光
Many pharmaceutical substances are optically active in the n that they rotate an incident plane of polarized light so that the transmitted light emerges at a measurable angle to the plane of the incident light. This property is characteristic of some crystals and of many pharmaceutical liquids or solutions of solids. Where the property is possd by a liquid or by a solute in solution, it is generally the result of the prence of one or more asymmetric centers, usually a carbon atom with four different substituents. The number of optical isomers is 2n, where n is the number of asymmetric centers. Polarimetry, the measurement of optical rotation, of a pharmaceutical article may be the only convenient means for distinguishing optically active isomers from each other and thus is an important criterion of identity and purity.
很多药用物质具有光学活性,他们能够使入射的平面偏振光旋转,这样射出的光线与入射光线的角度形成可测量的角度。这个性质是一些结晶状物体或者药用液体或固体的溶液所具有的特性。在某种液体或者溶液中的溶质具有该性质的情况下,这通常是存在着一个或者多个不对称中心的结果,经常是一个碳原子与四个不同的取代基。光学异构体的数量是2 n,在此
neversaygoodbye歌词n是不对称中心的数量。药用物质的旋光测定法,即测定光学旋转的方法,也许是用于区分具有光学活性的异构体的方法中唯一简便的方法。因此,该方法是鉴别和纯度的一个重要标准。
Substances that may show optical rotatory power are chiral. Tho that rotate light in a clockwi direction as viewed towards the light source are dextrorotatory, or (+) optical isomers. Tho that rotate light in the opposite direction are called levorotatory or (–) optical isomers. (The symbols d- and l-, formerly ud to indicate dextro- and levorotatory isomers, are no longer sanctioned owing to confusion with D- and L-, which refer to configuration relative to D-glyceraldehyde. The symbols R and S and and are also ud to indicate configuration, the arrangement of atoms or groups of atoms in space.)
能够表现出旋光能力的物质是手性的。那些朝向光源观察时按顺时针方向旋转光线的物质是右旋性的或者(+)光学异构体。(其符号d- l-,原先是用来表示右旋的和左旋的异构体,现在由于容易与D-L-化妆师资格证混淆而不再使用,这两个符号涉及与D-甘油醛相关的结构)。符号RS以及 也都是用于表示结构、原子或原子组在空间中的排列。
The physicochemical properties of nonsuperimposable chiral substances rotating plane polarized light in opposite directions to the same extent, enantiomers, are identical, except for this property and in their reactions with other chiral substances. Enantiomers often exhibit profound differences in pharmacology and toxicology, owing to the fact that biological receptors and enzymes themlves are chiral. Many articles from natural sources, such as amino acids, proteins, alkaloids, antibiotics, glycosides, and sugars, exist as chiral compounds. Synthesis of such compounds from nonchiral materials results in equal numbers of the enantiomers, racemates. Racemates have a net null optical rotation, and their physical properties may differ from tho of the component enantiomers. U of stereolective or stereospecific synthetic methods or paration of racemic mixtures can be ud to obtain individual optical isomers.
具有在相反方向旋转平面偏振光到同样程度的理化特性的不可重叠手性物质,即对映结构体,除了上述特性以及与其他手性物质进行的反应的区别之外,是完全相同的。由于生物受体和酶自身均是手性的,对映异构体经常在药理与毒理方面展现出深刻的差异。许多天然来源的物品,例如氨基酸、蛋白质、生物碱、抗生素、糖苷、蔗糖等,以手性化合物的
形式存在。使用非手性物料合成此类化合物导致等量的对映异构体和外消旋物。外消旋物有净无效旋光(南京英语培训班net null optical rotation),并且他们的物理特性可能与那些组成部分中的对应结构体不同。可以使用立体选择或立体专一的合成方法,或者外消旋混合物的分离,来获得单独的光学异构体。
Measurement of optical rotation is performed using a polarimeter.* The general equation ud in polarimetry is:
旋光的测量使用一个旋光计来完成。旋光测定法中通用的公式为:

where [ ] is the specific rotation at wavelength , t is the temperature, a is the obrved rotation in degrees ( ), l is the pathlength in decimeters, and c is the concentration of the analyte in g per 100 mL. Thus, [ ] is 100 times the measured value, in degrees ( ), for a solution containing 1 g in 100 mL, measured in a cell having a pathlength of 1.0 decimeter under defined conditions of incident wavelength of light and temperature. For some Pharmacopeial articles, especially liquids such as esntial oils, the optical rotation requirement is expresd in terms of the obrved rotation, a, measured under conditions
defined in the monograph.
其中,[ ]是在波长 条件下的比旋度,t是温度,a是观测到的以度( )为单位的旋转,l是以分米为单位的通道长度,c是以克/100mL为单位被分析物的浓度。因此,当100mL中含有1克的溶液,在通道长度为1.0botfly分米的单位中,并使用规定的入射光波长和温度的情况下,[ ]是测量值的100倍。对于某些药典物质来说,尤其是香精油之类的液体,旋光的规定表达为在该各论中所规定的条件下进行测定,所观察到的旋转,a
Historically, polarimetry was performed using an instrument where the extent of optical rotation is estimated by visual matching of the intensity of split fields. For this reason, the D-line of the sodium lamp at the visible wavelength of 589 nm was most often employed. Specific rotation determined at the D-line is expresd by the symbol:
历史上,旋光测定法检测所使用的仪器中,旋光的程度是通过肉眼观察分离区域的亮度。由于这个原因,可见波长589nm的纳灯的D-线是最经常使用的。用D-线检测的比旋度的表示方法为:

and much of the data available are expresd in this form. U of lower wavelengths, suc
h as tho available with the mercury lamp lines isolated by means of filters of maximum transmittance at approximately 578, 546, 436, 405, and 365 nm in a photoelectric polarimeter, has been found to provide advantages in nsitivity with a conquent reduction in the concentration of the test compound. In general, the obrved optical rotation at 436 nm is about double and at 365 nm about three times that at 589 nm. Reduction in the concentration of the solute required for measurement may sometimes be accomplished by conversion of the substance under test to one that has a significantly higher optical rotation. Optical rotation is also affected by the solvent ud for the measurement, and this is always specified.
并且,很多得到的数据用次形式表示。使用较低的波长,例如那些利用光电旋光计过滤掉汞灯线在578546436405365nm的最大能见度所产生的,已经被发现有利于增加检验敏感性,并最终导致供试品浓度的降低。通常情况下,观察到的旋光在436nm条件下大约是两倍于589nm,而在365nm条件下是三倍。检验必须的溶质浓度的减少有时候可以通过将供试品转换为具有显著高旋光性的物质来实现。旋光还受检验所用溶剂的影响,而此溶剂总是作出明确规定的。

USP30-NF25比旋度《781》
[Last edit by happyjyl]

consideration 词:usp 翻译 NF 迈克尔杰克逊scream比旋度 
该帖子作者被版主 happyjyl 高考1977影评10 积分, 2 经验,加分理由:感谢分享
收藏分享评分
暴走追风
marc
tc什么意思技术
财富
 
个人资料 加为好友
给他留言 帖子合集
沙发express yourlf  只看作者  回复于:2009-3-27 9:23:47
回复本贴 回复主题 编辑 举报 管理
It is now common practice to u other light sources, such as xenon or tungsten halogen, with appropriate filters, becau the may offer advantages of cost, long life, and broad wavelength emission range, over traditional light sources.
现在,使用其他光源,例如氙或者钨卤素,并使用适当的过滤器已经成为常规操作,因为这些光源与传统光源相比,可以提供在费用、使用寿命、宽波长发射范围等方面的优势。
Specific Rotation— The reference Specific rotation 781S in a monograph signifies that specific rotation is to be calculated from obrved optical rotations in the Test solution obtained as directed therein. Unless otherwi directed, measurements of optical rotation are made at 589 nm at 25 . Where a photoelectric polarimeter is ud, a single measurement, corrected for the solvent blank, is made. Where a visual polarimeter is employed, the average of no fewer than five determinations, corrected for the reading of the same tube with a solvent blank, is ud. Temperature, which applies to the solution or the liquid under test, should be maintained within 0.5 of the stated value. U the same cell for sample and blank. Maintain the same angular orientation of the cell in each reading. Place the cell so that the light pass through it in the same direction each time. Unless otherwi specified, specific rotation is calculated on the dried basis where Loss on drying is specified in the monograph or on the anhydrous basis where Water is specified.
比旋度:在各论中提到比旋度<781S>”意味着比旋度的计算将使用该各论中指定的供试液所观察到的旋光度。除非另外指出,旋光度的测量在25 589nm的条件下进行。如果使用
光电旋光计,只需一次测量并以溶剂作空白校正即可。如果旋光计是肉眼观察的,需要至少5次检测取平均值,并以溶剂作校正空白。供试溶液或者液体的温度应该保持在要求数值加减0.5 的范围内。进行样品检测和空白试验时,需使用同一个单元。在每一次读取数据的时候,使该单元保持同样的的成角方位(angular orientation)。放好单元,以便每次光线从同一个角度穿过它。除非另外指出,当该各论中要求干燥失重时,比旋度按干燥品计算,或者当该各论中要求水分时,在按无水计算。

本文发布于:2023-06-17 12:28:19,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/78/975512.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:使用   旋光   物质
相关文章
留言与评论(共有 0 条评论)
   
验证码:
推荐文章
排行榜
Copyright ©2019-2022 Comsenz Inc.Powered by © 专利检索| 网站地图