Determination of FOS-TAC

更新时间:2023-06-10 01:25:38 阅读: 评论:0

Targeted control of biogas plants with the help of FOS/TAC
PRACTICE REPORT LABORATORY ANALYSIS TITRATION FOS/TAC
A  biogas plant  functions most efficiently when substrates are added in amounts that are tailored to the  fermentation process . For this purpo, the exact status of the fermentation in the digester must be known and documented over a long period of time. This is achieved by regular, easily performed in-hou laboratory analys of the  FOS/TAC ratio . The operator is provided with exact information of the biodegradation performance of the digester and therefore of the  biogas production . Any interference with the process can be quickly identified and eliminated in a targeted manner. The plant is operated more efficiently and cost-effectively.
Authors: Ulrich Lossie
- Biogas consultant - DEULA Nienburg
Petra Pütz
- “Diplom-Ingenieur”, chemistry -  A pplications, laboratory products, HACH LANGE Biogas Plant Wambeln
Source: EnerCess
FOS/TAC: Reliable asssment of the fermentation process
Carrying out a FOS/TAC measurement
T ake a reprentative sample of the fermentation substrate.  R emove any coar components from the sample. It is crucial that sample preparation (filter, tea strainer, kitchen strainer or centrifuge) should always be carried out in the same way.    W eigh out 20 ml substrate and fill up with distilled water if necessary.  P lace the sample on a magnetic
stirrer and homogeni it continuously during the titration process.  T itration with 0.1 N H 2SO 4 to pH 5; note the volume (ml) of acid added.    T itration with 0.1 N H 2SO 4 to pH 4.4; note the volume (ml) of acid added.  C alculate FOS/TAC using the empirical formula (e Fig. 2).To measure the FOS/TAC ratio with the TIM 840 titrator, 5 ml prepared sample are introduced into a titration beaker containing a follower bar. 50 ml distilled water are then added, the beaker is positioned under the
measuring electrode of the TIM and the measurement is started. The following work steps ( , , ), which are usually rather tricky in practice, are performed by the titrator. After about 5 minutes the (automatic) titration is complete and the results are displayed.
The TAC and FOS values are calculated directly using a pre-programmed formula.
All measured values can be stored in the autotitrator and/or nt to a printer or PC.
FOS/TAC_ANALYSIS阿凡达字幕下载
What is the FOS/TAC ratio?The Federal Agricultural Rearch Centre (Bundesforschungsanstalt für Landwirtschaft/FAL) developed the FOS/TAC analysis from a titration test (Nordmann-Methode) in order to determine the quotient of the acid concentration and the buffer capacity in the fermentation substrate. FOS  stands for F lüchtige O rganische S äuren, i.e. volatile organic acids, and is measured in mg HAceq/l, while TAC  stands for T otales A norganisches C arbonat, i.e. total inorganic carbonate (alkaline buffer capacity), and is measured in mg CaCO 3/l.
The FOS/TAC ratio has long been recognid as a guide value for
asssing fermentation process. It enables process problems extending as far as the imminent inversion of the digester biology to be detected at an early stage, so that countermeasures can be initiated.
How is the FOS/TAC ratio determined?
Either by manual titration or, more easily and quickly, with a titrator, e.g. the
TIM 840 (e Fig. 1 and Fig. 4). Relative to manual titration, this is more accurate and saves veral minutes per sample.
2
Fig. 2: Calculation of the FOS/TAC ratio
Fig. 1: The TIM 840 titrator for FOS/TAC
行政管理专业就业前景
determination at the Wambeln biogas plant.
Asssment and u of the FOS/TAC ratio
In practice, a FOS/TAC ratio of 0.3 to 0.4 is normal, although each plant has its own optimal ratio. This can only be determined by long-term obrvation and regular checks, as there is a
strong dependence on the substrate. For example, plants that make u of renewable raw materials usually require a FOS/TAC ratio of 0.4 to 0.6 for stable operation.sausage是什么意思
3
“At the end of 2006 we started up our cofermentation plant. The fermentable material is a lective
mixture of food residues, pig slurry and chicken droppings. We control the fermentation process by carrying out regular FOS/TAC measurements with the TIM 840 from HACH LANGE. Usually the ratio is between 0.3 and 0.4 in the digester and between 0.2 and 0.3 in the post-digester. We can recogni a threat of acidification immediately, becau the ratio increas, and can take appropriate corrective action. In such a ca we change the composition of the biomass input, e.g. by increasing the proportion of pig slurry or chicken droppings, which increas the buffer capacity (TAC). Thanks to this simple monitoring method, we need have no fear that the process will crash.”Dipl.-Ing. Christian Nölle Quality Manager
Wambelner Bioenergiegellschaft mbH
Rules of thumb for the asssment of FOS/TAC ratios (empirical values provided by DEULA-Nienburg).The point at which the plant is operating most efficiently – i.e. when gas
production is at a maximum and there is no danger that the process will crash can only be determined by testing out a variety of options. Such a crash is extremely costly; veral weeks without gas production and the huge amount of work (pumping out, emptying the
digester, etc.) required to make the plant operational again can endanger the profitability of a whole
year.
hawksFig. 3: FOS/TAC curve of the Wambeln biogas plant over a period of 3 months
Technical data
D O C 042.52.20011.M a r 08
TIM 840/845 TECHNICAL DATA
Literature -  P rof. Dr. Peter Weiland, Christa Rieger, Institut für Technologie und Biosystem-technik, Abt. Technologie, Bundes-forschungsanstalt für Landwirtschaft (FAL): …Prozessstörungen frühzeitig erkennen“, BIOGAS Journal 4/06 -  D r. Jürgen Wie EnerCess GmbH, Ralf König HACH LANGE GmbH: …Prozessbegleitende Fermenterüber-wachung auf Biogasanlagen“, DVGW energie  wasr-praxis 09/2006-  H ACH LANGE Information …Rou-tine-Analytik für Biogas“, Art.Nr. DOC032.72.20007.APR07 -  K urzbedienungsanleitung: FOS/TAC-Messung mit dem HACH LANGE
who
TITRALAB
Table: Technical data, TIM 840/845
Fig. 4: HACH LANGE TIM 840 titrator for the determination of FOS/TAC, pH and redox potential
HACH LANGE Services
Contact us to place an order,  request information or receive
technical support.
Up to date and cure, with down-contrasting
loads, information and e-shop.
On site technical support.istyle
Quality assurance, complete with standard solutions, instrument
checks and test solutions.
Assurance of legal compliance, together with environmental protection via collection rvice for recycling of ud reagents.
HACH LANGE LTD Pacific Way Salford
GB-Manchester, M50 1DL Tel. +44 (0)161 8721487Fax +44 (0)161 uk uk
原理英语
美丽中国高清下载
上海健身培训
Phone: (0161) 872 14 87

本文发布于:2023-06-10 01:25:38,感谢您对本站的认可!

本文链接:https://www.wtabcd.cn/fanwen/fan/78/915650.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:下载   行政   培训
相关文章
留言与评论(共有 0 条评论)
   
验证码:
推荐文章
排行榜
Copyright ©2019-2022 Comsenz Inc.Powered by © 专利检索| 网站地图