PARTS LIST
- 3 -
Type
Reduced-bore quarter-turn valve
cereal是什么意思成人用英语怎么说
Pressure ratings
Body
DIN PN 25; ANSI 150Trim
DIN PN 25; ANSI 150
(Note the pressure/temperature curve)
Sizes
DN 80, 100, 150, 200, 250, 300Inch 3", 4", 6", 8", 10", 12"
Face-to-face dimensions
available什么意思Special
Temperature range
-40˚C ... +260˚C / -40…+500°F .
Inherent flow characteristic
Equal percentage.
Tightness
Tightness is tested in the direction by the arrow, e page 4,according to ISO 5208. The standard tightness of a metal-ated gment valve is 10 x ISO 5208 Rate D. This tightness corresponds to 1/100 of max at leakage allowed by ANSI/FCI 70.2 Class IV .
Valve pressure and leak test
All valves manufactured by Metso Automation undergo pres-sure testing. The test pressure of an R-ries valve body is 1.5 x the pressure rating and the test pressure of a at is 1.1 x the maximum permissible shut-off pressure. The test medium is water containing a corrosion inhibitor .
TECHNICAL SPECIFICATIONS
Maximum throttling differential pressure名字代码
for steel valves
Note! Noi and cavitation should also be taken into account when determining the maximum pressure differential of a
rq
titanium standard valves
Note! The maximum shut-off pressure differential of titanium
Valve body ratings
The are maximum working pressure ratings of the valve body only in accordance with ASME B16.34. The maximum allowed throttling differential pressure chart below deter-mines the differential pressure limitations according to specific rvice conditions.
* Rating at 100°C / 212°F
- 4 -
Maximum C v and resistance coefficients for R2_S ries valves
1) C v 100° corresponds to a 95° turning angle.beefup
websphere
SEATS DESIGNS
K Metal at
ACTUATOR MOUNTING POSITIONS
Note!
1. The most common positions are shown here. Should you wish to u some other mounting position, plea contact the nearest Metso Automation reprentative.
2. The mounting position can be changed at the site without extra accessories. See bulletin 3 R1L 71 for mounting,operation and maintenance.
3.If no mounting position is given, the actuator is mounted at the factory in position A-VU.
4.Following mounting positions are not possible A-VU, A-HU, A-HR, A-HL, A-VD, A-HD for following valve units:R2DS04/06-B1J10R2DS10/12-B1J20R2DS12/14-B1J25