Reference number ISO 8362-6:2010(E)
奥巴马父亲节演讲INTERNATIONAL STANDARD ISO 8362-6
Second edition 2010-06-01
英文演讲Injection containers and accessories — Part 6:
Caps made of aluminium-plastics combinations for injection vials
Récipients et accessoires pour produits injectables —
Partie 6: Capsules pour flacons d'injection fabriquées en un mélange aluminium-plastique
--`,,```,,,,````-`-`,,`,,`,`,,`---
ISO 8362-6:2010(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licend to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
helikonDetails of the software products ud to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for u by ISO member bodies. In the unlikely event that a problem relating to it is found, plea inform the Central Secretariat at the address given below.
COPYRIGHT PROTECTED DOCUMENT
© ISO 2010
All rights rerved. Unless otherwi specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body in the country of the requester. ISO copyright office
Ca postale 56 • CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyright@iso Web www.iso Published in Switzerland
--`,,```,,,,````-`-`,,`,,`,`,,`---
ISO 8362-6:2010(E)
Foreword
真皮养护
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be reprented on that committee. Interna
tional organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates cloly with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
百度语音翻译Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 8362-6 was prepared by Technical Committee ISO/TC 76, Transfusion, infusion and injection equipment for medical and pharmaceutical u.
This cond edition cancels and replaces the first edition (ISO 8362-6:1992), Clau 2, 6.2 and Table 2 of which have been technically revid.
ISO 8362 consists of the following parts, under the general title Injection containers and accessories:
⎯Part 1: Injection vials made of glass tubing
⎯Part 2: Closures for injection vials
hen怎么读⎯Part 3: Aluminium caps for injection vials
⎯Part 4: Injection vials made of moulded glass
⎯Part 5: Freeze drying closures for injection vials
⎯Part 6: Caps made of aluminium-plastics combinations for injection vials
⎯Part 7: Injection caps made of aluminium-plastics combinations without overlapping plastics part --`,,```,,,,````-`-`,,`,,`,`,,`---
ISO 8362-6:2010(E)
Introduction秘鲁首都
The materials from which injection containers (including elastomeric closures) are made are suitable primary packaging materials for storing injectable products until they are administered. However, in this part of ISO 8362, caps are not considered as primary packaging materials in direct contact with pharmaceutical preparations.
--`,,```,,,,````-`-`,,`,,`,`,,`---
INTERNATIONAL STANDARD ISO 8362-6:2010(E)
Injection containers and accessories —
Part 6:
Caps made of aluminium-plastics combinations for injection vials
1 Scope二级建造师考试题型
This part of ISO 8362 specifies caps made of aluminium-plastics combinations for injection vials as specified in ISO 8362-1 and ISO 8362-4.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 2768-1, General tolerances — Part 1: Tolerances for linear and angular dimensions without individual tolerance indications
ISO 2768-2, General tolerances — Part 2: Geometrical tolerances for features without individual tolerance indications覆盖的意思
ISO 8362-3, Injection containers and accessories — Part 3: Aluminium caps for injection vials
ISO 8872:2003, Aluminium caps for transfusion, infusion and injection bottles — General requirements and test methods
ISO 10985, Caps made of aluminium-plastics combinations for infusion bottles and injection vials — Requirements and test methods
3 Classification of types
Caps shall be classified as follows:
⎯ Type ZB: aluminium cap with central opening and plastics component; ⎯ Type ZD: aluminium cap with complete tear-off tab and plastics component.
--`,,```,,,,````-`-`,,`,,`,`,,`---