COLLECTION OF OSM/HA DECISIONS
Standard: EN 60335-1:2002 Sub clau: 3.1.11 and
3.8.2
Sheet n. OSM/HA 401
宋美龄美国国会演讲Page 1
Subject: Definitions Key words:
- possible unsafe operation
- not possible unsafe
operation 21st meeting 2007 Item 6.3
Question:
Bad on the definition in 3.1.11 we need for practical reasons to make a list of appliances who unint
entional operation may impair safety. It ems that some of them are clear (hobs, ovens, toasters or hand held blenders) but other are not always obvious (room heaters, tumble dryers).
Decision:
The annex document (available in PDF format) should be considered as a guide. Explanatory notes:
See document OSM/HA(ad hoc-WG) 01/07 (2007-08-22)
OSM/HA/Ad Hoc WG/01-07
2007-08-22
OSM/HA / Ad Hoc WG “listing standards for dangerous malfunction” (Malaga 2007-06-26)
The ad hoc WG “listing standard for dangerous malfunction” compod by Camiciotti
(convenor), Lescure, Skripsky, Tolksdorf, Fietz, Guirado, Kirby and Luettmann have prepared
the following list of standards considering the document discusd in the first day of the
OSM/HA meeting in Malaga (OSM HA (ES) 01-2007.doc), taking into account the item 2.3 of
the MT 23 report to London IEC/TC61 meeting 2006 (e below).
This list has been approved by OSM/HA by correspondence ): no comments received within
one month from the meeting).
Standards possible unsafe operation not possible unsafe operation
60335-2-2 X
60335-2-3 X
60335-2-4 X
60335-2-5 X 60335-2-6 X
60335-2-7 X
60335-2-8 X
60335-2-9 X
60335-2-10 X
60335-2-11 X
60335-2-12 Xpnas
60335-2-13 X
60335-2-14 X
60335-2-15 X
cellox60335-2-16 X
60335-2-17 X
60335-2-21 X
60335-2-23 X
60335-2-24 X
waltdisney
60335-2 -25 (only for combined) X
60335-2 -26 X
60335-2 -27 X
lect是什么意思60335-2-28 X
60335-2-29 X
60335-2-30 X
60335-2-31 X
60335-2-32 X
60335-2-34 X
60335-2-35 X
60335-2-36 X
60335-2-37 X
60335-2-38 X
60335-2-39 X高中出国留学需要什么条件
60335-2-40 X
60335-2-41 X
60335-2-42 X
60335-2-43 X
invader60335-2-44 X
60335-2-45 X
60335-2-47 X
60335-2-48 X
60335-2-49 X
60335-2-50 X
60335-2-51 X
60335-2-52 X
60335-2-53 X
60335-2-54 X
60335-2-55 X
60335-2-56 X
60335-2-58 X
60335-2-59 X
60335-2-60 X
60335-2-61 X
60335-2-62 X
60335-2-64 X
60335-2-65 X
60335-2-66 X
60335-2-67 X
60335-2-68 X
60335-2-69 X
60335-2-70 X
60335-2-71 X
60335-2-72 X
60335-2-74 X
60335-2-75 X
60335-2-76 X
新视野大学英语读写教程第三册答案60335-2-77 X
60335-2-78 X
60335-2-79 X
60335-2-80 X
60335-2-81 X
60335-2-82 X
debug是什么意思
60335-2-83 X
60335-2-84 X
60335-2-85 X
60335-2-86 X
60335-2-87 X
60335-2-88 X
60335-2-89 X
60335-2-90 (for combined only) X
60335-2-91 X
60335-2-92 X
60335-2-94 X
60335-2-95 X
60335-2-96 X
60335-2-97 Xsavvy翻译
60335-2-98 X
60335-2-99 X
60335-2-100 X
60335-2-101 X
60335-2-102 X
60335-2-103 X
60335-2-104 X
60335-2-105 X
60335-2-106 X
2. Part 1 modifications (MT 23 report for London meeting)
(3) Inquiry regarding the appliances starting; is it to become dangerous malfunction or not
was received and discusd. MT23 decided to make recommendation to TC61 that:
Vacuum cleaner: Yes, must not start has high power motor and no Locked Rotor test
Hand held hair curler or hairdryer: Yes, - the hair dryer must not start
Water dispenr or Water cleaner: No
Washing machine or dishwasher tumble dryer: No
Sewing machine: No becau of low motor power
Oven: Not resulted to dangerous malfunction, except only in the ca where operation is possible with “door open” under careless u (forgotten things in cavity) Microwave oven: No – it is already covered by the Part 2. It is also covered by fire condemnation test; door-lock requires mechanical switch.