          611A 换控制板步骤
1.Power–up the unit――― (supply ON)
2.propo用法Does the operating display”P–000” appear生病的英文 yes 往下  no 跳到7.步(有报警的解决报警)third
3. Set P–051 to 4H(remove write protection 打开写保护
4. Set P–097 to 0H(start initialization)初始化
5. Set P–052 to 1H(write into FEPROM 写入FEPROM
6. Wait until P–052 is again t to 0H,then switch the converter off and 2 s after the operating display has been canceled,  power–up again 等待2秒52自动变为0H 断电重启。
7. Display ”P–095” or ”P–096
8. Enter and check 输入以下参数
P–095 power modulecode number
. P-096 :ENTER the motor typevariable
P-098 :ENTER the numter of encoder puls per motor revolution。 
9. Set P–097 to 1H  ”SEtUP” is displayed
10. Wait until the operating display  P–000 appears
11.IS a special motor ud,where there is no code number definded for P-096? 确认是不是西门子专用电机。
1)Yes:  enter  p-159---p-176
t p-177 to 1 (calculate motor data) wait until p-177 is again t to 0H (可能不用这步)
Set P–051 to 4H  Set P–052 to 1H
Wait until P–052 is again t to 0H (write into FEPROM)pets是什么12
2)No 12
12. Check, and if required, change the following parameters:
P–014 normalization nt
P–015 offt correction nt
P–024 normalization nt
P–016 ramp–up time, ramp–fct. generator 1
P–017 ramp–down time, ramp–fct. generator 1
P–029 maximum motor speed nmaxmot
P–021 to P–023, relay respon values of the
P–027 speed monitoring
P–039 to P–043 torque limits
tired是什么意思
P–047to p050
P–057 to P–058 open–controlled range
经济开发区英文
南京朗阁P–059 to P–060 limits
P–081 to P–089 freely–programmable
terminal functions
P–113 to P–114 speed tpoints
托业考试真题P–185 to P–194, freely–programmable
P–241 to P–246 Relay functions
13.值改过Set P–052 to 1H
Wait until P–052 is again t to 0H (write into FEPROM)
14. Check all parameterized functions and if required change
值改过Set P–052 to 1H
Wait until P–052 is again t to 0H (write into FEPROM)
15.Set P–051 to 0H.Set write protection